Product Category Software Saia PG5® Controls Suite

Saia PG5® Controls Suite

  • The Saia PG5® Controls Suite contains everything required to implement and operate automation solutions with SBC instrumentation, control and automation (ICA) devices.
    This includes programming and engineering tools as well as libraries and ready-made logic, regulation and automation modules. It also contains application software for Windows PCs.

Extract from System Catalogue

System Catalogue : Software

Extract 26-215_B0100 System Catalogue : Software

System Catalogue
Software for Windows PCs

ENG18d .pdf 3.13 MB Download
FRA18d .pdf 3.15 MB Download
GER18d .pdf 3.16 MB Download
ITA18d .pdf 3.14 MB Download

Saia PG5® Core

The Saia PG5® Core contains the following components:

  • Project Manager (administers complex installations of networked PCD controllers, including documentation)
  • Network Configurator (integrated network editors for theconfiguration of devices and communications networks)
  • Device Configurator (configuration of hardware parameters on the controller)
  • Symbol Editor (administers all local, global and network symbols and symbol groups.
    Auto-allocation largely dispenses with the need for fixed addressing)
  • Programming methods (integrated programming environments: FUPLA [function block diagram], S-Edit [instruction list IL] and Graftec [sequential function chart] )
  • Libs (standard libraries which quickly and easily enable all the core functions of the ICA/automation technology)
  • WebEditor (for WebSCADA functions in every controller)
  • PG5-Projectmanager

    The configurations and applications are created, changed and managed in the Saia PG5 Project Manager. The Saia PG5 Project
    Manager is the central linchpin for all work with Saia PCD controllers.

  • Saia PG5® FUPLA (function block diagram)

    FUPLA is SBCs own function block diagram editor. It differs in many respects from other graphical programming interfaces:

     

    • One FUPLA file can contain several program blocks. This means that one file can encompass an entire machine function. In symbolic programming, each program block is given an individual symbol name. This prevents collisions during the build.
    • FUPLA blocks are organized into pages. Each page can produce several outputs so that entire functions can be seen at a glance on one page.
    • Graphical functions (FBoxes) not only have inputs and outputs, but also parameter windows for configuring and online modification.

Link to the different PG5 versions

Local FAQ Deutschland / Fupla

  • Why can't I store a Fupla file (and my PC claims that the disk is full)? (FAQ #101636)
  • Why do I get the "Error 161: New macro name '_COMSTN2' is not part of library"? (FAQ #101446)
  • How does the "disable" feature for Fupla pages work? (FAQ #101366)
  • Why are the inputs 8100 and 8101 continously "high" in my fupla file? (FAQ #101363)
  • Why do I get an error message "Internal symbols not defined" when building a PG5 project with HDLog file FBoxes? (FAQ #101263)
  • Why is the Help of the analogue FBoxes not available? (FAQ #101261)
  • How to calculate the power of a number with the FBox? (FAQ #101240)
  • How to change the base of a logarithm (FAQ #101238)
  • How does the transfer of the Clock work with the "Transmit Integer" FBox (FAQ #101199)
  • Why do Fupla symbols disappear (e.g. from a DDC Suite FBox )? (FAQ #101095)
  • Error list of the "Advanced Text Mail Initialisation" FBox (FAQ #100964)
  • Why does the FBox "Send SMS Indirect" generate a warning during compilation? (FAQ #100889)
  • Why is the ICC activity time 00:00 in the Modem Driver F-Box not supported? (FAQ #100830)
  • Error on build of a Fupla file containing EIB FBoxes : "symbol not defined: _eib_group._RCV.FBUFFER"! (FAQ #100824)
  • Changing language in Fupla FBox Selector provokes an error (FAQ #100812)
  • Why are the alarms not displayed in the "Web Alarming" list? (FAQ #100749)
  • Web Alarming doesn't work, the alarms don't appaer on the Web Server! (FAQ #100733)
  • Where can I find the fupla libraries for Web Trending and Alarming ? (FAQ #100732)
  • Installed F-Boxes are not available (FAQ #100723)
  • Alarming: When OnLine in fupla, FBox 10 Alarm displays xxxx instead of the values! (FAQ #100694)
  • Bug report concerning FBox library "Historic Data Logging" version 1.3.000 (FAQ #100688)
  • Why do I get the warning "Parameter Name not used in macro _HdaInit"? (FAQ #100687)
  • Can I disassemble a PG5 project for modifying it? (FAQ #100676)
  • Analogue modules read wrong values while beeing online with PG5 (FAQ #100631)
  • Why does the message "Error 395: sfupanl5.srx:Local and global symbols have the same name..." appear? (FAQ #100542)
  • SFup analog error of PG5 V1.4.100 (FAQ #100540)
  • How to calibrate HVC analog input Fbox? (FAQ #100538)
  • Guidelines for programming S-Bus communication (FAQ #100537)
  • How to create an Application Symbol (A-symbol)? (FAQ #100519)
  • Error message Invalid value appears when entering a correct date in the F-Box Clock holidays (FAQ #100448)
  • Why does it create errors on build when two PCD2.W745 F-Boxes are used in the same Fupla File? (FAQ #100441)
  • What to do after an "Operand Error 320: Invalid FB parameter"? (FAQ #100433)
  • Buffering of PCS1.Cxxx RTC (FAQ #100373)
  • FUPLA SBUS communication (FAQ #100352)
  • SFup error "macro _HEAINI6 is not part of library" when opening Fupla Editor (FAQ #100344)
  • "SAIA_ASSERT failed" error on resize FBox in Fupla (FAQ #100335)
  • Unresolved externals _HEAVAC... on build of Heavac project (FAQ #100333)
  • How to make systems symbols with HVC Fbox internal variables? (FAQ #100250)
  • After download CPU goes in Halt: checksum fail! (FAQ #100249)
  • Why is it a bad programming practice to generally declare symbols as globals? (FAQ #100245)
  • What's the difference between the communication mode MC4 and MC5? (FAQ #100202)
  • SASI error of S-BUS master IP FBox (FAQ #100184)
  • Read and write FBox Adjust Parameters (FAQ #100165)
  • Why are the Heavac Dialog FBoxes not present in PG5 1.4, 2.0 or 2.1? (FAQ #100150)
  • What is the difference between the media types "Constant" and "K Constant"? (FAQ #100123)
  • Disappeared Windows of PG5 Project Editor and Fupla Editor (FAQ #100115)
  • Fbox Write/Read EEprom and the instruction SYSRD/SYSWR must not be used in XOB 0! (FAQ #100066)
  • Global symbols not added when adding Fupla or IL File to a CPU (FAQ #100007)

Local FAQ Deutschland / SEdit (IL programming)

  • Why can't I send more than 512 bytes using the STXT instruction? (FAQ #101468)
  • Why is the error bit 7 or 8 set when I try to execute a "Backup DB to flash"? (FAQ #101466)
  • Can I create an array inside of an array of symbols? (FAQ #101460)
  • How to define a comma as separator in interpreted texts? (FAQ #101392)
  • Is it possible reading the PCD "IP address" from the user program? (FAQ #100952)
  • PCD instruction wich allows to copy a text in to a other text. (FAQ #100886)
  • Is it possible to give an Array of flags as FB parameters? (FAQ #100724)
  • XOR and OR calculations in IL - surprising results (FAQ #100720)
  • How to place a macro parameter into a text? (FAQ #100672)
  • Why does the error message "Multi-defined Unique Program Identifier DB 3999" appears when trying to rebuild an uploaded project? (FAQ #100547)
  • Where to find the ASCII table? (FAQ #100486)
  • How to organise the used FBs best? (FAQ #100294)
  • Block select mode in IL Editor (FAQ #100263)
  • Why is it a bad programming practice to generally declare symbols as globals? (FAQ #100245)
  • Error Message 41; Multi-defined symbol after viewing/editing IL code (FAQ #100212)
  • SASI error of S-BUS master IP FBox (FAQ #100184)
  • Why is the constant type in the compiled code different as in my IL code? (FAQ #100129)
  • What is the difference between the media types "Constant" and "K Constant"? (FAQ #100123)
  • Fbox Write/Read EEprom and the instruction SYSRD/SYSWR must not be used in XOB 0! (FAQ #100066)
  • Why is the instruction DSP not supported on Saia PCD® COSinus systems? (FAQ #100034)
  • Global symbols not added when adding Fupla or IL File to a CPU (FAQ #100007)

Local FAQ Deutschland / Graftec

  • When adding a transition (Fupla) to a project, compiling is not possible anymore. Multi-defined symbol (FAQ #101122)
  • Graftec: Can't open the activ Transition! (FAQ #100190)
  • Not possible to open a Graftec file! (FAQ #100102)

Local FAQ Deutschland / Network configurator

  • What is the signification of the PG5 assembling message "Error 1096: DBX initialization data too big"? (FAQ #101511)
  • How to configure a Profi-S-I/O network with a PCD3.M2 as master? (FAQ #101367)
  • DP/Belimo gateway display error message after program download to the PCD (FAQ #100976)
  • The error message: "Configuration too large appears" if a Saia PCD® Slave is added to a network (FAQ #100911)
  • Too strong limitation imposed by S-Net Configurator (FAQ #100717)
  • Are the modules PCD3.W800, PCD3.A810 and PCD3.A860 supported by the PCD3.T760? (FAQ #100504)
  • Is it possible to be Profibus DP Master and Profi S-I/O slave on a PCD2.M480 at the same time (FAQ #100497)
  • Negative values from PCD3.T760 are not interpreted correctly on the PCD (FAQ #100466)
  • Incompatibility of old FW and new Profibus DP configurator (FAQ #100319)
  • Problems when trying to import a *.gsd file into DP Network Configurator (FAQ #100295)
  • How to configure a PCD3.W745 on a PCD3.T760? (FAQ #100214)
  • It's possible to use my old GSD data's in new PG5 projects? (FAQ #100157)

Local FAQ Deutschland / HMI Editor

  • Does the display of a PCS1.Cxxx or a PCD7.D23x support Cyrillic? (FAQ #101730)
  • Why is there still 1 alarm in Buffer after the flag S.HMI.ALACLEAR has been activated? (FAQ #101439)
  • Why on the PG5 HMI Editor the play menu is shown shifted? (FAQ #101089)
  • Why does my PCD7.D23x jump back to the root menu while I'm working on it? (FAQ #100829)
  • HMI Editor 1.4.2xx: Not possible to leave the root menu! (FAQ #100826)
  • How can I acknowledge HMI alarms over the user program? (FAQ #100819)
  • Why does the Error 42: Symbol not defined:_SHMI appears on build (FAQ #100807)
  • Why is there an "Error 31: Syntax error, in macro" on build? (FAQ #100806)
  • HMI Editor Text loss in Standby Menu (FAQ #100797)
  • The PCD7.D23x displays nothing when icons are used in HMI Editor Lib 1.4 210! (FAQ #100734)
  • When Display PCD7.D2xx/D170 is not connected in multipoint topology the application using an HMI file doesn't run properly! (FAQ #100701)
  • Is it possible to read out the "Alarm Buffer" of the HMI-Editor? (FAQ #100696)
  • Why is the message "index out of bounds" displayed when opening the HMI-editor (FAQ #100673)
  • "HMI: Wrong library version: xxxxxx" with a DDC Suite project (FAQ #100660)
  • Why is the error message Error 42:...Symbol not defined:_SHMI._INT.LED displayed on build (FAQ #100650)
  • Why does the scroll bar and some menu lines in HMI get lost? (FAQ #100573)
  • How to use the root variable of the HMI Editor? (FAQ #100484)
  • Why appears the message "Ram Text not in Ram" on the Screen instead of the menu line? (FAQ #100481)
  • Why does a part of the HMI Internals Tree get lost? (FAQ #100459)
  • Why does the error "Missing FB parameters" shows up when builidng a Project with HMI Trend objects? (FAQ #100427)
  • Why does the HMI editor create warnings? (FAQ #100425)
  • Why does the backlight of a PCD7.D23x not work correctly in BUS Mode? (FAQ #100408)
  • Why does the General Acknowleg Flag not disappear, even if no more alarms are pending? (FAQ #100407)
  • If the cycle time is very long the D23x-terminal is not able to execute the program properly. (FAQ #100372)
  • How to display more than 5 digits using HMI Editor! (FAQ #100368)
  • Do not use '<' and '>' in HMI menus or objects! (FAQ #100363)
  • Why are LED, F-Key and Buzzer variables not supported in Topology Bus Terminals? (FAQ #100361)
  • HMI Editor and PCD3.M_ or PCD2.M480: Wrong characters are display instead of value with Format #####! (FAQ #100360)
  • Error message: Wrong library version: xxxxx Must be xxxxx or higher (FAQ #100351)
  • Functions in alarm buffer are not working correctly (FAQ #100346)
  • Error message on build: HMI: Wrong library version: 13000. Must be 13042 or higher (FAQ #100246)
  • Why can the status not be changed? (FAQ #100242)
  • Problems during the installation of the HMI Editor (FAQ #100199)
  • Error messages on build (FAQ #100196)
  • RS 485 connections to terminals using the HMI Editor (FAQ #100136)
  • Alarm acknowledgement can't be protected by Password! (FAQ #100114)
  • Not possible to set again the date 00.00 in HVC Clck_x Fbox once it has been changed (FAQ #100024)
  • Wrong values are set when changing a value on the terminal (FAQ #100018)
  • Cursor of PCD7.D23x is shown as "ü" (FAQ #100015)
  • Symbol import (FAQ #100008)

Local FAQ Deutschland / Symbol Editor

  • Why are the values of some resources overwritten by the HMI Editor? (FAQ #101629)
  • How are the "Dynamic media addresses" (e.g. register addresses) handled by PG5? (FAQ #101533)
  • Can I create an array inside of an array of symbols? (FAQ #101460)
  • How can I (re-)address symbols with static addresses? (FAQ #100794)
  • Bug report concerning Watch Window in PG5 SP1.4.130 (FAQ #100686)
  • PG5 V1.4.100 first edition doesn't handle global symbols correctly (FAQ #100541)
  • How to create an Application Symbol (A-symbol)? (FAQ #100519)
  • Behaviour of Symbol Editor when importing already existing resources (FAQ #100424)
  • PG5 symbol naming conventions and the scope of symbol types (FAQ #100375)
  • Why is it a bad programming practice to generally declare symbols as globals? (FAQ #100245)
  • Error Message 41; Multi-defined symbol after viewing/editing IL code (FAQ #100212)
  • Error Message "Multi defined symbol" for no reason? (FAQ #100171)
  • What is the difference between the media types "Constant" and "K Constant"? (FAQ #100123)
  • Global symbols not added when adding Fupla or IL File to a CPU (FAQ #100007)

Local FAQ Deutschland / Project Manager

  • What is the signification of the history entry "Resisters Fail"? (FAQ #101722)
  • What is the signification of the error: "Failed to copy to/from Flash..." (FAQ #101502)
  • Why can't I delete or rename any program file from a PG5 add-on tool? (FAQ #100880)
  • When downloading a programme in a PCS1, a warning displays "user program will write into Text/DB segement this will fail because PCD contains Flash Eprom..." (FAQ #100827)
  • Not possible to go on line a 2nd time over a PGU connection (on the port 0 D-Sub connector)! (FAQ #100761)
  • Dwnload All Failed: error reading file when *im5 file from PG5 1.2 download to PG 5 1.4! (FAQ #100692)
  • Bug report concerning FBox library "Historic Data Logging" version 1.3.000 (FAQ #100688)
  • Why do I get the warning "Parameter Name not used in macro _HdaInit"? (FAQ #100687)
  • PG5 1.4.130: Application Directory not configured! (FAQ #100659)
  • How can I configure a PCD to receive its IP address using DHCP? (FAQ #100643)
  • I forgot the password for my PCD/PCS! How can I access it again? (FAQ #100639)
  • PG5 blocked by the virus protection software "Antivir" (FAQ #100619)
  • PG5 build error "Too many FB parameters" even if the FB parameters are correct (FAQ #100559)
  • What to do after an "Operand Error 320: Invalid FB parameter"? (FAQ #100433)
  • What is the reason for the Error 31: File.wsp: Syntax error? (FAQ #100431)
  • Test Station / CPU (FAQ #100353)
  • After download CPU goes in Halt: checksum fail! (FAQ #100249)
  • Can I change the address of the unique program identifier? (FAQ #100229)
  • Auto-allocation/dynamic space overflow for type... (FAQ #100178)
  • Corrupted Flash user memory makes writing HW settings or program impossible (FAQ #100146)
  • Disappeared Windows of PG5 Project Editor and Fupla Editor (FAQ #100115)
  • PCD7.T120 converter RS 232 - RS 485 doesn't work with PG5 and visualisation! (FAQ #100099)
  • After each build the project manager is asking for still another build (FAQ #100009)

S-Web Technology

  • On HTML5 Web-Projects, created with Web-Editor8, why it is not possible to transfer the user and password after a url jump as it was possible on Java/MB? (FAQ #102035)
  • HDLog in WE8: slow navigation (FAQ #101965)
  • What means the error "Out of memory heap 3" (FAQ #101962)
  • Why I get Message Window"Do you want to run this application?" by starting a Webproject? (FAQ #101952)
  • Why IMaster Java Applet no longer run with Chrome? (FAQ #101951)
  • After a „Reload“, the displayed HDLog Trend is not focused on the right, most actual, time (FAQ #101945)
  • Web-Editor8, why the content of the Container variable is not displayed on the web-browser or the MB-display? (FAQ #101925)
  • Why after a update of the Microbrowser Android app to the version 2.0.0_4 the error message 'file not found' is shown? (FAQ #101918)
  • Why the error message ‘no such component found’ is shown on the web page? (FAQ #101917)
  • After the update of Java to Java version 7, (update 6 or 7) a Java warning message is shown on my PC browser when accessing a web page stored on the PCD. (FAQ #101793)
  • How to change the Favicon of a Web Project (FAQ #101782)
  • WebEditor project with HDLog File to flash-memory: macro tries to load a wrong CSV-File (FAQ #101737)
  • Why does the Micro Browser stop working with Error "File not found xxxx.teq"? (FAQ #101724)
  • File written to the file system by the PCD can’t be accessed with HTTP protocol (FAQ #101686)
  • What means the Error-6./alarm.exe?-6&sta failed? (FAQ #101674)
  • Why are the Webserver password levels not working with firmware 1.14.xx or later? (FAQ #101613)
  • How to disable borders and scrollbars when running the Microsoft Internet Explorer in Kiosk mode? (FAQ #101588)
  • Are there known problems when accessing the PCD FTP server with FileZilla? (FAQ #101586)
  • Why doesn't the Web Builder from PG5 2.0 find the license? (FAQ #101585)
  • What do parameters 'speed' and 'priority' mean which get displayed on the status page of the PCD? (FAQ #101513)
  • How long can I record data with the "HDLog to File FBox" (in csv format) using a 1 GB SD Card? (FAQ #101437)
  • How many web-clients can be connected at the same time to the S-Web Server over Ether-S-Bus? (FAQ #101431)
  • Problem with the FBox HD Log to File if the dynamic space of registers is defined as <1000 or >=10 000 (FAQ #101429)
  • Why is the same entry created several times by the "HDLog to File" FBox library? (FAQ #101421)
  • Which GIF-file formats are supported by the SBC S-Web technologies and how can I generate such GIFs? (FAQ #101409)
  • Why is it not possible to compile the project if I add a curve in the HDLog to file macro? (FAQ #101375)
  • Practical settings for the alarming macro in use with DDC Suite (FAQ #101342)
  • How many HDLog trend variables can I log into one single CSV-file? (FAQ #101341)
  • S-Web Editor recommendations for VGA MicroBrowser Panel projects (FAQ #101340)
  • Why does the S-Web Editor warn about deletion of unused HTML tags in csv-file? (FAQ #101338)
  • How can I prevent the Java Applet to be re-loaded when displaying my WebEditor created web pages? (FAQ #101288)
  • Why do I get an error message "Internal symbols not defined" when building a PG5 project with HDLog file FBoxes? (FAQ #101263)
  • Why is it not possible to compile a PG5 project containing a Web-Builder file on a PC with Chinese Windows? (FAQ #101250)
  • Why is the webpage not displayed? Class not found exception (FAQ #101230)
  • It’s possible to protect my web pages stored on the PCD, so that they can’t be copied? (FAQ #101229)
  • How to load a web application from a PCD/PCS (without Ethernet port) to a remote PC with the use of a CE web-panel? (FAQ #101215)
  • Why is the webpage not displayed? Class not found exception. Strange characters are displayed on top of the webpage. (FAQ #101200)
  • What is the "WebServer2" on Saia PCD® COSinus systems? (FAQ #101191)
  • Has the Web Server Time Allocation any influence? (FAQ #101179)
  • How to hide the address bar on the IE7 or to put IE7 in to full screen mode? (FAQ #101148)
  • Why the webpage is not displayed on the web-browser of the PC? Error message "Class not found" is displayed (but working fine on MB-webpanel) (FAQ #101142)
  • Why my Web-Application is no more reacting after clicking on "Save Logs to file" button? (FAQ #101035)
  • Why do the values on an eXP Web Panel freeze? (FAQ #100975)
  • Why is the message: "Failed to get data on alarm.exe" displayed on the alarming page? (FAQ #100963)
  • Why are the alarm texts not displayed? (FAQ #100934)
  • Is it possible to store the web pages on a Web Panel? (FAQ #100931)
  • Can I store files locally on a MB Panel (in order to increase communication performance)? (FAQ #100924)
  • Does the Web-Editor allow to access array variables of PG5 symbolic names? (FAQ #100915)
  • Is it possible to use symbolic names of PG5 resources on the Web-Editor if container offset is used? (FAQ #100914)
  • How to use registers with addresses > 9999 on a web project? (FAQ #100913)
  • Is it possible to know on the PCD if the Web-Application on a Web-Panel is running? (FAQ #100909)
  • Why is the web-Server on the PCD is accessible over two different socket ports? (FAQ #100900)
  • How to set the index of the Alarmlist FBox? (FAQ #100876)
  • How to uninstall the Webserver password page? (FAQ #100873)
  • Negative values with decimal point are not displayed correctly on the CE panel (FAQ #100842)
  • S-Web Editor 5.13.00 dependencies (FAQ #100810)
  • Why are the Webpages not always displayed? How to adjust the timeout of the WebServer? (FAQ #100808)
  • Is it possible to run another application (Internet Explorer) from the Microbrowser on a CE panel? (FAQ #100768)
  • Installed F-Boxes are not available (FAQ #100723)
  • Applet malfunction after installing Sun Java Platform Edition 6 (Version 1.6) (FAQ #100708)
  • Internet Explorer 7 does not support FTP connection (FAQ #100703)
  • Alarming: When OnLine in fupla, FBox 10 Alarm displays xxxx instead of the values! (FAQ #100694)
  • The PCD goes in HALT with a BUS ERROR if many accesses to the WebServer are executed (FAQ #100658)
  • Why is the Internet Browser frozen after a few hours (FAQ #100648)
  • Why is the message "syntax error" / "syntax error in tag" displayed instead of a value (FAQ #100632)
  • Why are negativ values not displayed correctly? (FAQ #100630)
  • URL Jump doesn't work with Microbrowser CE Terminal (FAQ #100617)
  • What file names are allowed in the Web-Editor (FAQ #100552)
  • Why is the message: "cannot create page content yet" appears from time to time (FAQ #100527)
  • If I want to display Web pages on a PCD Web Panel CE, what is the difference between the use of Internet Explorer and the Micro Browser? (FAQ #100506)
  • How to use the display of the MicroBrowser on the PCD Web Panel CE in full screen mode? (FAQ #100505)
  • How to store a web page content which was uploaded from the PCD in to a Excel sheet? (FAQ #100476)
  • Why does the error message "Can't generate ...web.itq length is 0" appers when generating a file with the Webbuilder? (FAQ #100429)
  • PCD2.M170 or PCS1: WEB Server works only if a WEB project is downloaded in the PCD! (FAQ #100380)
  • Why does the web page show "No component selected" instead of the media value? (FAQ #100379)
  • What tools/technology should be used to create pages for the SBC-S-Web concept? (FAQ #100020)

WebConnect

  • File written to the file system by the PCD can’t be accessed with HTTP protocol (FAQ #101686)
  • How to include values in Excel from a PCD with CGI commands? (FAQ #101574)
  • How many web-clients can be connected at the same time to the S-Web Server over Ether-S-Bus? (FAQ #101431)
  • Why are the values not displayed on the webpage when connecting over modem with Webconnect (FAQ #101430)
  • Why can't my WebConnect find the SComm driver? (FAQ #101127)
  • Where does SBC.Net WebConnect store its configuration? (FAQ #101126)
  • Why does WebConnect not close automatically when shutting down the PC? (FAQ #101125)
  • Why is my start-page not displayed in the browser when using SWebConnect? (FAQ #101018)
  • How to connect a PCD behind an (A)DSL router? (FAQ #101007)
  • How can I handle, let's say, 'unlimited' numbers of connections to the S-Web server? (FAQ #100982)
  • Why can't I download an I/O configuration to a PCD3.T760? (FAQ #100971)
  • Not possible to install PG5 1.4 on a PC with Windows 7 or on a PC on general (FAQ #100969)
  • Is it possible to have subfolders in the Webpages folder for Webconnect? (FAQ #100961)
  • Information’s about TAPI modem settings on PG5. (FAQ #100891)
  • Can I enter an IP address as URL in Web-Connect? (FAQ #100867)
  • How to close a connection of S-Web-Connect? (FAQ #100822)
  • Why are the configured stations in SWebConnect on a Win CE panel not saved (FAQ #100758)
  • Why does the S-WebConnect not start? (FAQ #100736)
  • Why is the "variables list" not working when online using a http-direct connection? (FAQ #100725)
  • Can a WebConnect connection over modem be forced to disconnect after a certain time? (FAQ #100572)
  • How to hang up a modem connection in a S-Web editor project (FAQ #100566)
  • The variables are not visible on the Webpages: "No message" is displayed instead of the value! (FAQ #100561)
  • PG5 controls suite on a linux system (FAQ #100426)
  • May I change the port number for requests via WebConnect? (FAQ #100347)
  • Which Java(TM) Virtual Machine is recommended for the use with the Monitorio? (FAQ #100293)
  • File names containing space characters do cause problems (e.g. "no response") (FAQ #100253)
  • Why it's not possible to start the WebConnect SW on my WIN-XP PC? (FAQ #100210)
  • What files should be downloaded to the PCD and what files placed in the WebPages folder? (FAQ #100021)

Web Editor5

  • What means the error "Out of memory heap 3" (FAQ #101962)
  • Why does the Java-Applet for Webpages do not start anymore after the Java Update to version 1.7.0_65? (FAQ #101912)
  • After the update of Java to Java version 1.7.0_51-b13 it's no more possible to display the web pages created with the S-Web editor on PG5 1.4, PG5 2.0 and PG5 2.1 (FAQ #101878)
  • Why do I get a "Security information" pop-up window and the message "The application's digital signature has expired" when I load the content of the PLCs Webserver? (FAQ #101811)
  • DDC suite: why the alarm list on the alarm web-page does display ghost alarms? (FAQ #101776)
  • What the messge "Error -6: cgi-bin/alarm2.exe?open ListeAlarmeGénéral failed !" means? (FAQ #101772)
  • Why is the "SBC HDlog files" window missing in the Web Editor Project configuration? (FAQ #101747)
  • How can I disable or customize the loading messages during applet initialization? (FAQ #101746)
  • Why do I get the error message "Windows - Out of Virtual Memory" on my PCD7.D61xxTL010 eXP panel? (FAQ #101742)
  • How to license the S-Web Editor without PG5? (FAQ #101728)
  • Why does the Micro Browser stop working with Error "File not found xxxx.teq"? (FAQ #101724)
  • Why are all the groups and priorities of my "Alarming 2" feature displayed with "0"? (FAQ #101694)
  • When should I use the new "Alarming 2" feature in Fupla and WebEditor? (FAQ #101690)
  • Can I initiate a reload of a S-Web project on a MB Panel (PCD7.D4xxx) without touching the MB Panel? (FAQ #101687)
  • File written to the file system by the PCD can’t be accessed with HTTP protocol (FAQ #101686)
  • Why is the "Action Mode" "Broadcasted Action" not supported anymore in WebEditor version 5.15.02? (FAQ #101684)
  • Disable the Logout Macro on Condition (FAQ #101668)
  • What does the error message "ERROR while generating Macro's Temp folder" in the WebEditor mean? (FAQ #101667)
  • Error in S-WebEditor 5.15.02 when using the new online alarming macros (FAQ #101654)
  • Which MB Panel firmware does support the "Alarming 2" features of the S-WebEditor 5.15.02? (FAQ #101648)
  • Why is the "select" button missing in the "Macro Find/Replace" dialog? (FAQ #101643)
  • Why are some options in Project configuration missing? (FAQ #101627)
  • Where from can I get the icons used in the HEAVAC S-Web Demo? (FAQ #101611)
  • Why do spaces " " in entered texts get displayed as plus signs "+"? (FAQ #101609)
  • What does the message "Some views needs to be saved in a teq format newer as the 5.13 release" mean? (FAQ #101578)
  • Why do I get an error "unresolved externals" when working with HVC templates in the S-Web Editor? (FAQ #101491)
  • How to use "special" (country-specific) fonts for the alarm texts of a VGA MB panel? (FAQ #101427)
  • Why is my gif not displayed correctly on the MB panel? (FAQ #101401)
  • HDLog feature and error message: Can't open $INCLUDE file: FileSysMac.lib (FAQ #101346)
  • HDLog File Error messages (FAQ #101326)
  • Why does the error message "more than 383 elements in DB" appear? (FAQ #101312)
  • How can I use scalable HTML-files on non-MicroBrowser browsers? (FAQ #101305)
  • Why is the time displayed in the online trending on an MB Panel not correct? (FAQ #101302)
  • Why are my trends from the "HDLog to file" FBoxes not updated? (FAQ #101299)
  • Why does the error message "loading file failed: KEYPAD.TEQ.teq or ALPHAPAD.TEQ.teq not found" appear? (FAQ #101287)
  • Why is the "Warning" button shown in a web project, but nothing happens when I click it? (FAQ #101281)
  • What's the best way to manage with HDLog file creation, saving and deleting? (FAQ #101276)
  • S-Web Editor 5.14.27 dependencies (FAQ #101273)
  • What are the new features of the S-Web Editor 5.14.30? (FAQ #101272)
  • Why does the PG5 build fail when using HDLog File FBoxes? (FAQ #101266)
  • Incompatibility of WebEditor and virus scanner "Trend Micro Internet Security Pro" (FAQ #101257)
  • Why does the offline trend show more data points than configured in the HDLog FBox? (FAQ #101246)
  • Is it possible to enter a variable (e.g. register content) into the alarm text of the S-Web Server and to display the text in the alarmlist? (FAQ #101245)
  • Why is the file not created on the file system and the "LogToFile" FBox shows an error? (FAQ #101235)
  • It’s possible to protect my web pages stored on the PCD, so that they can’t be copied? (FAQ #101229)
  • On the browser/microbrowser, is it possible to transfer container variable information from one web application (PCD) to an other web application (PCD)? (FAQ #101147)
  • Why isn't it possible selecting a PG5 2.0 resource from the S-Web Editor 5.14.xx? (FAQ #101141)
  • Why isn't it possible to write to a PCD resource from a MB VGA panel (with S-Bus)? (FAQ #101123)
  • Error message "Exception in CSpderControlEditorDoc" on the S-Web-Editor if a web page should be stored. (FAQ #101117)
  • How much memory does a container variable of the S-Web Editor use? (FAQ #101071)
  • Why my Web-Application is no more reacting after clicking on "Save Logs to file" button? (FAQ #101035)
  • Is there a list and description of the predefined container variables used on a Windows CE Micro-Browser? (FAQ #101002)
  • How can I create a Cross-Reference List of the PPO-variables used in the WebEditor? (FAQ #100992)
  • How can I close MicroBrowser Software with a WebEditor button? (FAQ #100986)
  • Why do the values on an eXP Web Panel freeze? (FAQ #100975)
  • Why are there gaps in trend? (FAQ #100938)
  • Does the Web-Editor allow to access array variables of PG5 symbolic names? (FAQ #100915)
  • Is it possible to use symbolic names of PG5 resources on the Web-Editor if container offset is used? (FAQ #100914)
  • How to use registers with addresses > 9999 on a web project? (FAQ #100913)
  • Is it possible to know on the PCD if the Web-Application on a Web-Panel is running? (FAQ #100909)
  • Is it possible to use a IMasterSaia_x.jar file that is not stored on the local PCD? (FAQ #100904)
  • How to use only a numeric keyboard on the CE-Panel? (FAQ #100902)
  • How to avoid that after displaying a new Web-Page on a MB-Display or a CE-Panel a hidden painter (button or other painter) on the new page is shown shortly for one second? (FAQ #100879)
  • Is it possible accessing PCD resources from a Web-Page in an indexed way? (FAQ #100878)
  • Why are my alarms not shown in the Microbrowser CE? (FAQ #100813)
  • S-Web Editor 5.13.00 dependencies (FAQ #100810)
  • My Start-Page of the WebEditor project isn't displayed (FAQ #100795)
  • Special links, actions and jumps associated to WebEditor Buttons (FAQ #100791)
  • Is it possible to add a new curve of the online trending during runtime of the Web-Page (FAQ #100784)
  • FTP clients to access the FTP server on Saia-Burgess Controls AG PCD® systems. (FAQ #100750)
  • Why are the alarms not displayed in the "Web Alarming" list? (FAQ #100749)
  • Web Alarming doesn't work, the alarms don't appaer on the Web Server! (FAQ #100733)
  • Where can I find the fupla libraries for Web Trending and Alarming ? (FAQ #100732)
  • How to change the column width of the alarming macro on the S-Web Editor? (FAQ #100711)
  • Applet malfunction after installing Sun Java Platform Edition 6 (Version 1.6) (FAQ #100708)
  • Bug report concerning FBox library "Historic Data Logging" version 1.3.000 (FAQ #100688)
  • Why do I get the warning "Parameter Name not used in macro _HdaInit"? (FAQ #100687)
  • Not all files have been distributed in the PG5 SP1.4.130 package (FAQ #100677)
  • What are persistent containers on the S-Web-Editor? (FAQ #100663)
  • It's possible to start up a mutlilingual Web-Panel with the last used language? (FAQ #100662)
  • It's possible to use persistent container variable on a CE Web-Panel? (FAQ #100661)
  • Why is the warning "TEQ file parse first char error file" displayed? (FAQ #100657)
  • Why is "No Message" shown instead of PPO values (on PCD1, PCD2.M1xx or PCS1)? (FAQ #100653)
  • HTML Tags and/or alarm texts not displayed in web-application (FAQ #100647)
  • GIF or TEQ files not displayed, although available (FAQ #100644)
  • How to use FKEYs on the Micro Browser Web Panel PCD7.D457BMCF/SMCF! (FAQ #100622)
  • How to display unicode texts in the WebEditor with "HTML TAG" (FAQ #100612)
  • How to read/write the RTC of the PCD on a S-Web page (FAQ #100567)
  • How to hang up a modem connection in a S-Web editor project (FAQ #100566)
  • What file names are allowed in the Web-Editor (FAQ #100552)
  • Bug report concerning FBox family "Historic data logging" (FAQ #100536)
  • Strange text shown in the browser before the Web-Editor applet view (FAQ #100495)
  • How can I resize a picture in a Web Editor project? (FAQ #100474)
  • How to put the browser in Fullscreen mode without scrollbar? (FAQ #100457)
  • What is the reason for the Error 31: File.wsp: Syntax error? (FAQ #100431)
  • What does "WARNING: Checked painter's size out of range" mean? (FAQ #100404)
  • Why does the web page show "No component selected" instead of the media value? (FAQ #100379)
  • The PCD Web Server timing possibilities (FAQ #100301)
  • How to use the "Order per view" checkbox of the Web Editor? (FAQ #100300)
  • How big should the RAM Disk size for the PCD Web Server be? (FAQ #100299)
  • Why is "No Message" displayed instead of the PCD media value? (FAQ #100292)
  • What is the reason for suddenly appearing strange symbol names like "aaaaaaaa"? (FAQ #100255)
  • Why does my Web Editor project not work correctly on the PCD? (FAQ #100254)
  • File names containing space characters do cause problems (e.g. "no response") (FAQ #100253)

Software (except PG5) / SCOMM

  • Are SBC devices affected by the zero-day vulnerabilities ‘Ripple20’, related to the low-level TCP/IP software library developed by Treck, Inc.? (FAQ #102036)
  • Can PG5 access more than 32 serial communication ports (ComPorts)? (FAQ #101339)
  • Information’s about TAPI modem settings on PG5. (FAQ #100891)
  • Memory leak from SCOMM on Windows XP (FAQ #100875)
  • SCommDll fails with strange status on multi core CPUs (FAQ #100674)
  • ScommDll doesn't work because of firewall software (FAQ #100323)
  • How to set up the SComm to connect a PCD over a server? (FAQ #100248)
  • Compatibility of the S-Bus OPC-Server with PG5 1.2 and PG5 1.3 (FAQ #100240)
  • Driver not available for user when OPC server was started by OPC client (FAQ #100238)
  • Is a driver for SBC S-Bus available? (FAQ #100179)

S-Web Technology / ADSL

  • Why are the horizontal and vertical lines in web pages created with PG5 2.3.175 and displayed in HTML5 Runtime or TEQ Runtime not displayed horizontally/vertically, but 'skewed' with an offset of one pixel? (FAQ #102055)
  • How to set up DynDNS on a router? (FAQ #101197)
  • How to know the IP Address of a device addressed with an URL? (FAQ #101064)
  • How to connect a PCD behind an (A)DSL router? (FAQ #101007)
  • How I have to configure my ADSL router? (FAQ #100454)
  • How can I know the TCP/IP address of a public e-mail server? (FAQ #100453)
  • Experiences with ADSL Routers (FAQ #100203)

Local FAQ Deutschland / Add on Tools

  • Why does the BACnet "Upload/Merge" not work on very busy IP networks? (FAQ #101417)
  • Each time when opening PG5 1.4 in Windows 7 or Windows Vista, a popup message about all Add on tools (e.g. Add-on Tool 'Web Builder-C' installed. ) installed appears! (FAQ #101073)

Local FAQ Deutschland / Installation

  • Why can't I store a Fupla file (and my PC claims that the disk is full)? (FAQ #101636)
  • Why do I get the "Error 161: New macro name '_COMSTN2' is not part of library"? (FAQ #101446)
  • Why can't I install a new patch for PG5 1.4.300? (FAQ #101306)
  • Problems on installation of PG5 1.4.300 (FAQ #100940)
  • "Internal Failure" by PG5 V1.x uninstall (FAQ #100330)

Local FAQ Deutschland / Stand Alone Downloader

  • How to download a PG5 project to a CPU without the full PG5 installation? (FAQ #100818)
  • PCMCIA card with 2 serial COM Ports (RS-232) suitable for S-Bus (FAQ #100764)
  • Download Program Failed: Failed to create serial number file! (FAQ #100625)

Software (except PG5) / SBC.Net Suite

  • It's possible to connect SBC PCD's directly to the internet? (FAQ #102060)
  • Is a driver for SBC S-Bus available? (FAQ #100179)

Local FAQ Deutschland / Device Configurator

  • Why the connection to the PCD over SOCKET is not working if DHCP is enabled in the device configurator? (FAQ #101872)
  • Why does PG5 1.4 show the error message "downloader not found" on HW settings download? (FAQ #101721)
  • Why is it not possible to choose minimal and maximal value in the device configurator for the PCD3 compact? (FAQ #101311)
  • Why can't I add an extension module to my PCD3 compact? (FAQ #101303)
  • The device configurator does not work in PG5 1.4 or the project manager PG5 2.0 does not open at all. (FAQ #101274)
  • Why is it not possible to configure the memory allocation of the PCD manually in PG5 2.0? (FAQ #101236)

S-Web Technology / Android- and iPhone Apps

  • Why are the horizontal and vertical lines in web pages created with PG5 2.3.175 and displayed in HTML5 Runtime or TEQ Runtime not displayed horizontally/vertically, but 'skewed' with an offset of one pixel? (FAQ #102055)
  • On PG5 2.3.192 projects, why the Web-Editor login macro does not work well if the web page is displayed on SBC Microbrowser Web-Panels or Windows Microbrowser App? (FAQ #102053)
  • Why does suddenly the Microbrowser-App on my iOS Apple device or Android device not work anymore, error message ‘unable to Verify App’ is shown on the device? (FAQ #102023)
  • Why after a update of the Microbrowser Android app to the version 2.0.0_4 the error message 'file not found' is shown? (FAQ #101918)
  • Is it possible to increase the Heap size for the SBC Micro Browser App for Android smartphones/tablet? (FAQ #101851)
  • Is there an Android application to display S-Web editor projects on Android devices? (FAQ #101794)
  • Why can't I see the content of the PCD WebServer on my Android- or iPhone App? (FAQ #101777)

Web Editor8

  • Why are the horizontal and vertical lines in web pages created with PG5 2.3.175 and displayed in HTML5 Runtime or TEQ Runtime not displayed horizontally/vertically, but 'skewed' with an offset of one pixel? (FAQ #102055)
  • On PG5 2.3.192 projects, why the Web-Editor login macro does not work well if the web page is displayed on SBC Microbrowser Web-Panels or Windows Microbrowser App? (FAQ #102053)
  • It's possible to use existing PG5 and Web-Editor8 projects on PG5 2.3.192? (FAQ #102050)
  • On PG5 2.3.192, are the Web-Editor8 expressions @CO_ and @COFF_ working in the same way as on older PG5 versions? (FAQ #102049)
  • Why on PG5 2.3.192, the error message ‘Error 1279: xxx.fbd: Line 278: String name not defined’ is displayed after compilation of a Fupla project containing ‘Alarm advanced’ FBoxes? (FAQ #102048)
  • Why the error message ‘Unexpected token '+'’ is displayed after compilation of a Web-Editor8 project on PG5 2.3.192? (FAQ #102047)
  • On HTML5 Web-Projects, created with Web-Editor8, why it is not possible to transfer the user and password after a url jump as it was possible on Java/MB? (FAQ #102035)
  • Why does suddenly the Microbrowser-App on my iOS Apple device or Android device not work anymore, error message ‘unable to Verify App’ is shown on the device? (FAQ #102023)
  • Why on the web-editor 8 of PG5 2.2.140, the properties window is empty or tabs of the properties window are not visible? (FAQ #101997)
  • How could I start an application from Web project on a CE Web Panel (FAQ #101985)
  • HDLog in WE8: slow navigation (FAQ #101965)
  • What means the error "Out of memory heap 3" (FAQ #101962)
  • Why my trendcurves stored with HDLog File 3.0, are not displayed on a MB-Panel: Errormessage 'No such component found/LogFile1_Dxxxxxx.CSV' (FAQ #101938)
  • Web-Editor8, why the content of the Container variable is not displayed on the web-browser or the MB-display? (FAQ #101925)
  • Why the error message ‘no such component found’ is shown on the web page? (FAQ #101917)
  • Why the web project is displayed correctly on the PC browser but not on the MB panel? Error message 'start.html not found' is shown (FAQ #101908)
  • How can I smartly export and share with other programmers my own template libraries with subfolder-structure? (FAQ #101893)
  • Web-Editor 8, why it’s not possible to select a single alarm line from the web alarming template? (FAQ #101888)
  • Why, it’s not possible to login to the web-page, the user login on the Web-Editor 8 doesn’t work? (FAQ #101885)
  • On the web browser or MB-Display, why the message 'Value out of bounds' is shown when trying to change a value with format DEC.1? (FAQ #101869)
  • WebEditor 8, Version 8.0.19.434 or older, project destroyed if the function scope is set to ‘project’ (FAQ #101825)
  • Can I initiate a reload of a S-Web project on a MB Panel (PCD7.D4xxx) without touching the MB Panel? (FAQ #101687)

/ Device Configurator

  • How does the battery / power-up check work on the PCD? (FAQ #101929)
  • Why the message IPM not present appears with PG5 2.1.210 on not NT PCD's? (FAQ #101877)
  • Ether S-Bus communication is no more working after the update to PG5 2.1.210 (FAQ #101867)
  • Nach einem Update eines bestehenden Projektes auf PG5 2.1.210 funktioniert die Ether-S-Bus Kommunikation nicht mehr (FAQ #101866)
  • On PG5 2.1.200, Fupla crash when double-clicking on some FBoxes (FAQ #101836)

Communication / S-Web Technologie

  • Are the LonWorks devices PCD2.F240, PCD3.F2400 and PCD7.R582 still available? (FAQ #102064)
  • Nach einem Update von Java auf die Java Version 1.7.0_51-b13 ist es nicht mehr möglich Webseiten die mit dem S-Web Editor von PG5 1.4, PG5 2.0 oder PG5 2.1 erstellt wurden anzuzeigen (FAQ #101882)
  • Nach einem Update von Java auf die Java Version 1.7.0_51-b13 ist es nicht mehr möglich Webseiten die mit dem S-Web Editor von PG5 2.0 oder PG5 2.1 erstellt wurden anzuzeigen (FAQ #101879)

/ Online Configurator

  • Why the message xxx.5hw "File not found" appears? (FAQ #101928)

PG5 2.1 / PG5 2.3

  • It's possible to use existing PG5 and Web-Editor8 projects on PG5 2.3.195? (FAQ #102071)
  • Why does the PCD2.M5540 show the history error message 'FABINFO CRC FAIL' or the entry 'Fab. Date (year/week): 2000/00; BAD PROD INFO CHECKSUM' in the diagnostic file and in the hardware info of the PG5 Online configurator? (FAQ #102040)
  • Why the PG5 2.1, 2.2 or 2.3 update manger application is no more working and it’s not possible to download files from PG5 update manager server? (FAQ #102020)
  • Shall I use PG5 2.3, PG5 2.2, 2.1, 2.0 or PG5 1.4 for my next project? (FAQ #102018)

PCD2 / PG5 2.3

PG5 2.3

  • It's possible to use existing PG5 and Web-Editor8 projects on PG5 2.3.195? (FAQ #102071)
  • It's possible to connect SBC PCD's directly to the internet? (FAQ #102060)
  • Why are the horizontal and vertical lines in web pages created with PG5 2.3.175 and displayed in HTML5 Runtime or TEQ Runtime not displayed horizontally/vertically, but 'skewed' with an offset of one pixel? (FAQ #102055)
  • Why the error message ‘Direct I/O access is not allowed by this device type' is displayed if the PG5 project is compiled? (FAQ #102054)
  • On PG5 2.3.192 projects, why the Web-Editor login macro does not work well if the web page is displayed on SBC Microbrowser Web-Panels or Windows Microbrowser App? (FAQ #102053)
  • It's possible to use existing PG5 and Web-Editor8 projects on PG5 2.3.192? (FAQ #102050)
  • On PG5 2.3.192, are the Web-Editor8 expressions @CO_ and @COFF_ working in the same way as on older PG5 versions? (FAQ #102049)
  • Why on PG5 2.3.192, the error message ‘Error 1279: xxx.fbd: Line 278: String name not defined’ is displayed after compilation of a Fupla project containing ‘Alarm advanced’ FBoxes? (FAQ #102048)
  • Why the error message ‘Unexpected token '+'’ is displayed after compilation of a Web-Editor8 project on PG5 2.3.192? (FAQ #102047)
  • Are devices or software developed from Saia-Burgess Controls affected by the Domain Name System (DNS) vulnerabilities, published with the report name NAME:WRECK? (FAQ #102046)
  • Are devices or software developed from Saia-Burgess Controls affected by AMNESIA:33 or SUNBURST? (FAQ #102042)
  • Is it possible to install and use more than one PG5 2.3 version on the same PC? (FAQ #102041)
  • Why does the PCD2.M5540 show the history error message 'FABINFO CRC FAIL' or the entry 'Fab. Date (year/week): 2000/00; BAD PROD INFO CHECKSUM' in the diagnostic file and in the hardware info of the PG5 Online configurator? (FAQ #102040)
  • For the PCD3.T665/T666/T668 it’s possible to define on the PG5 device configurator own FTP users, service key or the web-server password? (FAQ #102038)
  • Why the PG5 Update manager does not work, error message ‘An error occurred during the connection to the sever’ is displayed? (FAQ #102037)
  • E-mail forwarding service is currently not available (FAQ #102034)
  • Not possilbe to call to the main number of SBC Murten 026 580 30 00 (FAQ #102033)
  • On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH2? (FAQ #102031)
  • Why the PG5 2.1, 2.2 or 2.3 update manger application is no more working and it’s not possible to download files from PG5 update manager server? (FAQ #102020)
  • Shall I use PG5 2.3, PG5 2.2, 2.1, 2.0 or PG5 1.4 for my next project? (FAQ #102018)
  • The special FBox library PCD7_D7 is now available for PG5 2.0. (FAQ #101356)
  • Shall I use PG5 2.3, PG5 2.2, 2.1, 2.0 or PG5 1.4 for my next project? (FAQ #101282)
  • Which PG5 version is compatible with what operating system? (FAQ #100405)

PG5 2.3 / Fupla

  • It's possible to use existing PG5 and Web-Editor8 projects on PG5 2.3.195? (FAQ #102071)
  • Why the error message ‘Direct I/O access is not allowed by this device type' is displayed if the PG5 project is compiled? (FAQ #102054)
  • Is it possible to install and use more than one PG5 2.3 version on the same PC? (FAQ #102041)
  • Why the PG5 Update manager does not work, error message ‘An error occurred during the connection to the sever’ is displayed? (FAQ #102037)
  • Why the PG5 2.1, 2.2 or 2.3 update manger application is no more working and it’s not possible to download files from PG5 update manager server? (FAQ #102020)
  • Shall I use PG5 2.3, PG5 2.2, 2.1, 2.0 or PG5 1.4 for my next project? (FAQ #102018)
  • The special FBox library PCD7_D7 is now available for PG5 2.0. (FAQ #101356)
  • Shall I use PG5 2.3, PG5 2.2, 2.1, 2.0 or PG5 1.4 for my next project? (FAQ #101282)

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

Download