The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

  • PG5 2.2

  • PG5 Suite V2.2.235

Documentation

What's new in PG5 2.2

Flyer 2.2.220 What's new in PG5 2.2

2.2.220 .pdf 3.06 MB Download
2.2.220 .pdf 3.11 MB Download
2.2.220 .pdf 3.16 MB Download

PG5 2.2/2.3 User's guide

Manual 26-732 PG5 2.2/2.3 User's guide

ENG12 .pdf 6.34 MB Download
GER12 .pdf 8.35 MB Download
FRA12 .pdf 6.34 MB Download
ITA12 .pdf 6.39 MB Download

System Catalogue : Software

Extract 26-215_B0100 System Catalogue : Software

System Catalogue
Software for Windows PCs

ENG18d .pdf 3.13 MB Download
FRA18d .pdf 3.15 MB Download
GER18d .pdf 3.16 MB Download
ITA18d .pdf 3.14 MB Download

System Catalogue : Controls Suite PG5 - Core

Extract 26-215_B0111 System Catalogue : Controls Suite PG5 - Core

Saia PG5® Core – everything you need at all times

ENG16 .pdf 0.96 MB Download
FRA16 .pdf 0.97 MB Download
GER16 .pdf 0.97 MB Download
ITA16 .pdf 0.96 MB Download

Additional Documentation (Manuals, Workshops) can be found on the Controls Suite DVD

PG5 Suite for Windows 7 SP1, Windows 8, Windows 8.1 and Windows 10

This version allows to use the full functionality of PG5 2.2 for 90 days.
Link to an overview of the new features of PG5 2.2.

PG5 V2.2.235, installer for 32-bit Windows

Software V2.2.235/32 PG5 V2.2.235, installer for 32-bit Windows

2.2.235 548 MB Download

PG5 V2.2.235, installer for 64-bit Windows

Software V2.2.235/64 PG5 V2.2.235, installer for 64-bit Windows

2.2.235 548 MB Download

Full PG5 V2.2.235 package (complete DVD content)

Software V2.2.235 full Full PG5 V2.2.235 package (complete DVD content)

2.2.235 full 2300 MB Download

Installation Guide PG5 2.2

Manual 2.2.220 Installation Guide PG5 2.2

2.2.220 .pdf 1.06 MB Download
2.2.220 .pdf 1.02 MB Download
2.2.220 .pdf 1.03 MB Download
2.2.220 .pdf 0.92 MB Download

Patch 1 for PG5 2.2.235

Patch1 of PG5 2.2.235

 

  • This version does not include a complete installation package of PG5 2.2.235 and must be installed over PG5 2.2.235
  • Before installing the patch files, make sure that you have installed PG5 2.2.235
  • This patch of the PG5 contains important corrections for PG5 2.2.235 and S-Web Editor 8 included in PG5 2.2.235
  • Informations about the corrections can be found on the 'version overview' page.

 

Installation:

For PG5:

  • Unzip of the file and copy the files on the corresponding directories analogous to the directory structure in the zip file   
    c:\Program Files (x86)\SBC\PG5 V2.2.235\
    c:\Program Files (x86)\SBC\PG5 V2.2.235\BACnet\Preset\
    c:\Program Files (x86)\SBC\PG5 V2.2.235\BACnet\Preset2014\
    c:\Program Files (x86)\SBC\PG5 V2.2.235\DeviceTemplates\

 

For Web-Editor8

  • Executing the seutp file install the Web-Editor8, version 8.3.2.32 on the directory
    c:\Program Files (x86)\SBC\PG5 V2.2.235\WebEditor8\

Patch 1 for PG5 2.2.235 (PG5 files)

Software Patch 1 for PG5 2.2.235 (PG5 files)

.zip 14.98 MB Download

Patch 1 for PG5 2.2.235 (S-Web Editor 8)

Software Patch 1 for PG5 2.2.235 (S-Web Editor 8)

8.3.2.032 158 MB Download

Microsoft .Net 4.5.2 Framework must be installed on the PC.
The Microsoft .Net Framework 4.5.2 can be found in the above DVD Image in the folder "Windows\DotNet\NDP452-KB2901907-x86-x64-AllOS-ENU.exe"

 

 

  • Firmware requirement for full PG5 functionality

It's important to use the latest PCD COSinus 1.22 xx (or higher) firmware versions for full compatibility with PG5 2.2

Remarks

  • Usage of PG5 2.2.2xx
    PG5 2.2.1xx and PG5 2.2.2xx can be in installed in parallel on the same PC.
    By default, PG5 2.2.1xx will use the projects and F-Box libraries in the directory:
    C:\Users\Public\SBC\PG5 V2.2.1xx\
    And PG5 2.2.2xx does use the directory:
    C:\Users\Public\SBC\PG5 V2.2.2xx\
    Means that if a PG5 2.2.1xx project is transferred to PG5 2.2.2xx, the project must first be imported into PG5 2.2.2xx.
    Custom F-Box libraries from PG5 2.2.1xx must be installed again in PG5 2.2.2xx.
  • BACnet revision 14:
    BACnet revision 14 requires a PCD and BACnet FW >= 1.28.xx.
    The PCD and BACnet FW >= 1.28.xx does not support BACnet revision 9.
    BACnet revision 9 requires a PCD and BACnet firmware <= 1.26.xx.
    The PCD and BACnet firmware <= 1.26.xx does not support BACnet revision 14.
  • Use of PG5 2.2.130 or newer
    Windows Start menu

    Since PG5 2.2.130, in the Windows Start menu, the Saia PG5 applications are accessible directly under the folder ‘PG5 Suite V2.2.130’ and no more under the folder ‘Saia Burgess Controls’.
    This change has been made in order to be compatible with the Windows 10 start menu that’s accept only one level of folder
  • Use of PG5 2.2.100 or newer
    Since the version 2.1.300, the PG5 folders structure on the PC has changed compared to previous PG5 version and therefore it's necessary to:
    - Re-register PG5 2.2.xxx
      (the existing registration.key from PG5 2.1 can be re-used but
       it's necessary to use a new user.key; the user.key of PG5 2.1. does not work on PG5 2.2)

Known issues

  • PG5 2.2.140, Web-Editor8:
    properties window is empty or tabs of the properties window are not visible
    See FAQ 101997 
    Solution is done with Web-Editor 8.3.0.749
  • PG5 2.2.140, Fupla: broken input and output connectors
    when connector are directly connected to a F-Box
    See FAQ 101996 
    Solution is done in Hotfix 1 for PG5 2.2.140
  • PG5 2.2.130, BACnet configurator not possible to map analogue values to PCD medias.
    See FAQ 101981 
    Solution is done in Hotfix 1 for PG5 2.2.130
  • PG5 2.2.130, F-Box HEVAC ‘Override digital’ and ‘Override numeric’ not possible to access to the F-Box internal adjust parameters from scada or web. See FAQ 101980 
    Solution is done in Hotfix 1 for PG5 2.2.130

Good to know

  • PG5 Licensing
    In order to use PG5 version 2.2, a new ‘USER.KEY’ file is needed. The key file from V2.1, V2.0 or V1.4 cannot be used. However, you can run V2.2 as a Demonstration version for 90 days without a key file. The ‘USER.KEY’ file is available from your Saia representative.
    This key file registers your Company and enables the features of the PG5 which are needed.
    PG5 user registration
    Since PG5 V2.1 we have introduced registration for individual PG5 developers, in addition to the existing company registration. The file name of the user registration file is 'REGISTRATION.KEY'
    It's possible to use the same 'REGISTRATION.KEY' from PG5 2.1 also in PG5 2.2
    When the PG5 first opens, you will be asked to register yourself as a PG5 User.
    A PG5 user is entitled to free software updates, free technical support, and other benefits.
    Demonstration version must complete the PG5 user registration before the PG5 can be used.
    It means that PG5 V2.2 with a demo key will not run without having a valid user registration.
    Licensed users, with a valid ‘USER.KEY’ file, can skip the developer registration indefinitely.
  •  

  • Compatibility with previous versions
    It's possible to install in parallel PG5 2.2, PG5 2.1, PG5 2.0 and PG5 1.4 on the same PC
    Compatibility with PG5 projects version 2.0 and PG5 2.1
    PG5 V2.0 and PG5 2.1 projects are upward compatible with PG5 V2.2, but not back again.
    Once a project has been opened with PG5 V2.2, it is not possible to open it again with the previous versions.
    We recommend to use different project directories for each PG5 version so they do not get mixed up.
    Projects made with the PG5 2.0, PG5 2.1 must be imported or restored in PG5 Version 2.2. This makes a new copy of the project and converts the files to the new format. The original project stays unchanged Compatibility with the user FBoxes written for PG5 2.0 PG5 2.1.
    The FBox libraries written for PG5 2.1 are fully compatible with PG5 Version 2.2.
    There is no change concerning the FBox definition files, the source files and the help files.
    Compatibility with PG5 projects version 1.4
    PG5 V1.4 projects are upward compatible with PG5 V2.2, but not back again. Once a project has been opened with the new PG5 V2.2, it is not possible to open it again with the previous versions (since files are converted to the new format). We recommend to use different project directories for each PG5 version so they do not get mixed up. Projects made with the PG5 1.4 must be imported or restored in PG5 Version 2.2. This makes a new copy of the project and converts the files to the new format. The original project stays unchanged.

    Compatibility with the user FBoxes written for PG5 1.4 or previous versions

    The FBox libraries written for PG5 1.4 or old versions have to be update to be used under PG5 V2.2

    This update can be supported by the library author or the end user itself.

 

The S-Web editor 5 and S-Web editor 8 which are supplied together with PG5 2.2.100 does contain the new java applet 5_15_03 from 03.02.2016. (Version 5.15.0321)
This java applet does solves the problems which are described on the FAQ 101811 and FAQ 101793

 

Supported operating systems are

  • Microsoft Windows 7 SP 1 (32 or 64 bit version)
  • Microsoft Windows 8
  • Microsoft Windows 8.1
  • Microsoft Windows 10

Windows 95, 98, ME, NT, 2000, Vista and XP are no longer supported by PG5 2.2 or later.

 

A short list of the advantages of PG5 2.0/PG5 2.1/PG5 2.2 and when to work with which PG5 version can be found in FAQ 101282.

 

For best performance, we recommend installing PG5 2.2 on a PC with a multi-core CPU running at a minimum of 2GHz with a minimum of 4GB RAM (8GB or more is recommended). The installation package requires about 700MB of free space on your hard disk.

Products not supported by PG5 2.2

The following products and protocols are not supported by PG5 2.2:

  • PCD4 and PCD6
  • S-Bus RIO (used with PCD1.T240)
  • Profibus FMS

For existing projects which are running with these controllers or protocols we recommend using PG5 1.4.300.

Web Editor5

  • What means the error "Out of memory heap 3" (FAQ #101962)
  • Why does the Java-Applet for Webpages do not start anymore after the Java Update to version 1.7.0_65? (FAQ #101912)
  • After the update of Java to Java version 1.7.0_51-b13 it's no more possible to display the web pages created with the S-Web editor on PG5 1.4, PG5 2.0 and PG5 2.1 (FAQ #101878)
  • Why do I get a "Security information" pop-up window and the message "The application's digital signature has expired" when I load the content of the PLCs Webserver? (FAQ #101811)
  • DDC suite: why the alarm list on the alarm web-page does display ghost alarms? (FAQ #101776)
  • What the messge "Error -6: cgi-bin/alarm2.exe?open ListeAlarmeGénéral failed !" means? (FAQ #101772)
  • Why is the "SBC HDlog files" window missing in the Web Editor Project configuration? (FAQ #101747)
  • How can I disable or customize the loading messages during applet initialization? (FAQ #101746)
  • Why do I get the error message "Windows - Out of Virtual Memory" on my PCD7.D61xxTL010 eXP panel? (FAQ #101742)
  • How to license the S-Web Editor without PG5? (FAQ #101728)
  • Why does the Micro Browser stop working with Error "File not found xxxx.teq"? (FAQ #101724)
  • Why are all the groups and priorities of my "Alarming 2" feature displayed with "0"? (FAQ #101694)
  • When should I use the new "Alarming 2" feature in Fupla and WebEditor? (FAQ #101690)
  • Can I initiate a reload of a S-Web project on a MB Panel (PCD7.D4xxx) without touching the MB Panel? (FAQ #101687)
  • File written to the file system by the PCD can’t be accessed with HTTP protocol (FAQ #101686)
  • Why is the "Action Mode" "Broadcasted Action" not supported anymore in WebEditor version 5.15.02? (FAQ #101684)
  • Disable the Logout Macro on Condition (FAQ #101668)
  • What does the error message "ERROR while generating Macro's Temp folder" in the WebEditor mean? (FAQ #101667)
  • Error in S-WebEditor 5.15.02 when using the new online alarming macros (FAQ #101654)
  • Which MB Panel firmware does support the "Alarming 2" features of the S-WebEditor 5.15.02? (FAQ #101648)
  • Why is the "select" button missing in the "Macro Find/Replace" dialog? (FAQ #101643)
  • Why are some options in Project configuration missing? (FAQ #101627)
  • Where from can I get the icons used in the HEAVAC S-Web Demo? (FAQ #101611)
  • Why do spaces " " in entered texts get displayed as plus signs "+"? (FAQ #101609)
  • What does the message "Some views needs to be saved in a teq format newer as the 5.13 release" mean? (FAQ #101578)
  • Why do I get an error "unresolved externals" when working with HVC templates in the S-Web Editor? (FAQ #101491)
  • How to use "special" (country-specific) fonts for the alarm texts of a VGA MB panel? (FAQ #101427)
  • Why is my gif not displayed correctly on the MB panel? (FAQ #101401)
  • HDLog feature and error message: Can't open $INCLUDE file: FileSysMac.lib (FAQ #101346)
  • HDLog File Error messages (FAQ #101326)
  • Why does the error message "more than 383 elements in DB" appear? (FAQ #101312)
  • How can I use scalable HTML-files on non-MicroBrowser browsers? (FAQ #101305)
  • Why is the time displayed in the online trending on an MB Panel not correct? (FAQ #101302)
  • Why are my trends from the "HDLog to file" FBoxes not updated? (FAQ #101299)
  • Why does the error message "loading file failed: KEYPAD.TEQ.teq or ALPHAPAD.TEQ.teq not found" appear? (FAQ #101287)
  • Why is the "Warning" button shown in a web project, but nothing happens when I click it? (FAQ #101281)
  • What's the best way to manage with HDLog file creation, saving and deleting? (FAQ #101276)
  • S-Web Editor 5.14.27 dependencies (FAQ #101273)
  • What are the new features of the S-Web Editor 5.14.30? (FAQ #101272)
  • Why does the PG5 build fail when using HDLog File FBoxes? (FAQ #101266)
  • Incompatibility of WebEditor and virus scanner "Trend Micro Internet Security Pro" (FAQ #101257)
  • Why does the offline trend show more data points than configured in the HDLog FBox? (FAQ #101246)
  • Is it possible to enter a variable (e.g. register content) into the alarm text of the S-Web Server and to display the text in the alarmlist? (FAQ #101245)
  • Why is the file not created on the file system and the "LogToFile" FBox shows an error? (FAQ #101235)
  • It’s possible to protect my web pages stored on the PCD, so that they can’t be copied? (FAQ #101229)
  • On the browser/microbrowser, is it possible to transfer container variable information from one web application (PCD) to an other web application (PCD)? (FAQ #101147)
  • Why isn't it possible selecting a PG5 2.0 resource from the S-Web Editor 5.14.xx? (FAQ #101141)
  • Why isn't it possible to write to a PCD resource from a MB VGA panel (with S-Bus)? (FAQ #101123)
  • Error message "Exception in CSpderControlEditorDoc" on the S-Web-Editor if a web page should be stored. (FAQ #101117)
  • How much memory does a container variable of the S-Web Editor use? (FAQ #101071)
  • Why my Web-Application is no more reacting after clicking on "Save Logs to file" button? (FAQ #101035)
  • Is there a list and description of the predefined container variables used on a Windows CE Micro-Browser? (FAQ #101002)
  • How can I create a Cross-Reference List of the PPO-variables used in the WebEditor? (FAQ #100992)
  • How can I close MicroBrowser Software with a WebEditor button? (FAQ #100986)
  • Why do the values on an eXP Web Panel freeze? (FAQ #100975)
  • Why are there gaps in trend? (FAQ #100938)
  • Does the Web-Editor allow to access array variables of PG5 symbolic names? (FAQ #100915)
  • Is it possible to use symbolic names of PG5 resources on the Web-Editor if container offset is used? (FAQ #100914)
  • How to use registers with addresses > 9999 on a web project? (FAQ #100913)
  • Is it possible to know on the PCD if the Web-Application on a Web-Panel is running? (FAQ #100909)
  • Is it possible to use a IMasterSaia_x.jar file that is not stored on the local PCD? (FAQ #100904)
  • How to use only a numeric keyboard on the CE-Panel? (FAQ #100902)
  • How to avoid that after displaying a new Web-Page on a MB-Display or a CE-Panel a hidden painter (button or other painter) on the new page is shown shortly for one second? (FAQ #100879)
  • Is it possible accessing PCD resources from a Web-Page in an indexed way? (FAQ #100878)
  • Why are my alarms not shown in the Microbrowser CE? (FAQ #100813)
  • S-Web Editor 5.13.00 dependencies (FAQ #100810)
  • My Start-Page of the WebEditor project isn't displayed (FAQ #100795)
  • Special links, actions and jumps associated to WebEditor Buttons (FAQ #100791)
  • Is it possible to add a new curve of the online trending during runtime of the Web-Page (FAQ #100784)
  • FTP clients to access the FTP server on Saia-Burgess Controls AG PCD® systems. (FAQ #100750)
  • Why are the alarms not displayed in the "Web Alarming" list? (FAQ #100749)
  • Web Alarming doesn't work, the alarms don't appaer on the Web Server! (FAQ #100733)
  • Where can I find the fupla libraries for Web Trending and Alarming ? (FAQ #100732)
  • How to change the column width of the alarming macro on the S-Web Editor? (FAQ #100711)
  • Applet malfunction after installing Sun Java Platform Edition 6 (Version 1.6) (FAQ #100708)
  • Bug report concerning FBox library "Historic Data Logging" version 1.3.000 (FAQ #100688)
  • Why do I get the warning "Parameter Name not used in macro _HdaInit"? (FAQ #100687)
  • Not all files have been distributed in the PG5 SP1.4.130 package (FAQ #100677)
  • What are persistent containers on the S-Web-Editor? (FAQ #100663)
  • It's possible to start up a mutlilingual Web-Panel with the last used language? (FAQ #100662)
  • It's possible to use persistent container variable on a CE Web-Panel? (FAQ #100661)
  • Why is the warning "TEQ file parse first char error file" displayed? (FAQ #100657)
  • Why is "No Message" shown instead of PPO values (on PCD1, PCD2.M1xx or PCS1)? (FAQ #100653)
  • HTML Tags and/or alarm texts not displayed in web-application (FAQ #100647)
  • GIF or TEQ files not displayed, although available (FAQ #100644)
  • How to use FKEYs on the Micro Browser Web Panel PCD7.D457BMCF/SMCF! (FAQ #100622)
  • How to display unicode texts in the WebEditor with "HTML TAG" (FAQ #100612)
  • How to read/write the RTC of the PCD on a S-Web page (FAQ #100567)
  • How to hang up a modem connection in a S-Web editor project (FAQ #100566)
  • What file names are allowed in the Web-Editor (FAQ #100552)
  • Bug report concerning FBox family "Historic data logging" (FAQ #100536)
  • Strange text shown in the browser before the Web-Editor applet view (FAQ #100495)
  • How can I resize a picture in a Web Editor project? (FAQ #100474)
  • How to put the browser in Fullscreen mode without scrollbar? (FAQ #100457)
  • What is the reason for the Error 31: File.wsp: Syntax error? (FAQ #100431)
  • What does "WARNING: Checked painter's size out of range" mean? (FAQ #100404)
  • Why does the web page show "No component selected" instead of the media value? (FAQ #100379)
  • The PCD Web Server timing possibilities (FAQ #100301)
  • How to use the "Order per view" checkbox of the Web Editor? (FAQ #100300)
  • How big should the RAM Disk size for the PCD Web Server be? (FAQ #100299)
  • Why is "No Message" displayed instead of the PCD media value? (FAQ #100292)
  • What is the reason for suddenly appearing strange symbol names like "aaaaaaaa"? (FAQ #100255)
  • Why does my Web Editor project not work correctly on the PCD? (FAQ #100254)
  • File names containing space characters do cause problems (e.g. "no response") (FAQ #100253)

Web Editor8

  • Why are the horizontal and vertical lines in web pages created with PG5 2.3.175 and displayed in HTML5 Runtime or TEQ Runtime not displayed horizontally/vertically, but 'skewed' with an offset of one pixel? (FAQ #102055)
  • On PG5 2.3.192 projects, why the Web-Editor login macro does not work well if the web page is displayed on SBC Microbrowser Web-Panels or Windows Microbrowser App? (FAQ #102053)
  • It's possible to use existing PG5 and Web-Editor8 projects on PG5 2.3.192? (FAQ #102050)
  • On PG5 2.3.192, are the Web-Editor8 expressions @CO_ and @COFF_ working in the same way as on older PG5 versions? (FAQ #102049)
  • Why on PG5 2.3.192, the error message ‘Error 1279: xxx.fbd: Line 278: String name not defined’ is displayed after compilation of a Fupla project containing ‘Alarm advanced’ FBoxes? (FAQ #102048)
  • Why the error message ‘Unexpected token '+'’ is displayed after compilation of a Web-Editor8 project on PG5 2.3.192? (FAQ #102047)
  • On HTML5 Web-Projects, created with Web-Editor8, why it is not possible to transfer the user and password after a url jump as it was possible on Java/MB? (FAQ #102035)
  • Why does suddenly the Microbrowser-App on my iOS Apple device or Android device not work anymore, error message ‘unable to Verify App’ is shown on the device? (FAQ #102023)
  • Why on the web-editor 8 of PG5 2.2.140, the properties window is empty or tabs of the properties window are not visible? (FAQ #101997)
  • How could I start an application from Web project on a CE Web Panel (FAQ #101985)
  • HDLog in WE8: slow navigation (FAQ #101965)
  • What means the error "Out of memory heap 3" (FAQ #101962)
  • Why my trendcurves stored with HDLog File 3.0, are not displayed on a MB-Panel: Errormessage 'No such component found/LogFile1_Dxxxxxx.CSV' (FAQ #101938)
  • Web-Editor8, why the content of the Container variable is not displayed on the web-browser or the MB-display? (FAQ #101925)
  • Why the error message ‘no such component found’ is shown on the web page? (FAQ #101917)
  • Why the web project is displayed correctly on the PC browser but not on the MB panel? Error message 'start.html not found' is shown (FAQ #101908)
  • How can I smartly export and share with other programmers my own template libraries with subfolder-structure? (FAQ #101893)
  • Web-Editor 8, why it’s not possible to select a single alarm line from the web alarming template? (FAQ #101888)
  • Why, it’s not possible to login to the web-page, the user login on the Web-Editor 8 doesn’t work? (FAQ #101885)
  • On the web browser or MB-Display, why the message 'Value out of bounds' is shown when trying to change a value with format DEC.1? (FAQ #101869)
  • WebEditor 8, Version 8.0.19.434 or older, project destroyed if the function scope is set to ‘project’ (FAQ #101825)
  • Can I initiate a reload of a S-Web project on a MB Panel (PCD7.D4xxx) without touching the MB Panel? (FAQ #101687)

PG5 2.2

  • For the PCD3.T665/T666/T668 it’s possible to define on the PG5 device configurator own FTP users, service key or the web-server password? (FAQ #102038)
  • Why the PG5 Update manager does not work, error message ‘An error occurred during the connection to the sever’ is displayed? (FAQ #102037)
  • E-mail forwarding service is currently not available (FAQ #102034)
  • On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH2? (FAQ #102031)
  • Why the PG5 2.1, 2.2 or 2.3 update manger application is no more working and it’s not possible to download files from PG5 update manager server? (FAQ #102020)
  • Shall I use PG5 2.3, PG5 2.2, 2.1, 2.0 or PG5 1.4 for my next project? (FAQ #102018)
  • Why after an download of a PG5 2.2.230 project to the PCD, where BACnet revision 14 is used, the application program on the PCD doesn’t work correctly and have a randomly unexpected/unwanted functionality? (FAQ #102013)
  • PG5 2.1 and 2.2 with E-Line S-Bus communication library < 1.2.110, why the S-Bus communication on the master PCD stops either after a certain time? (FAQ #102009)
  • PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or after the download of the program? (FAQ #102008)
  • No Refresh from State of I/O's from E-Line Rio- Moduls after Fbox Update (FAQ #102001)
  • Why on the web-editor 8 of PG5 2.2.140, the properties window is empty or tabs of the properties window are not visible? (FAQ #101997)
  • Why does the fupla in PG5 2.2.140 deletes connexions? (FAQ #101996)
  • Why it’s not possible to distribute the corrections (hotfix files) for PG5 over the PG5 update manager? (FAQ #101983)
  • Why in PG5 2.2.130 it's not possible to map in the BACnet Configurator analogue values to PCD medias? (FAQ #101981)
  • On PG5 2.2.130, why it’s no more possible to access from scada or web page to the HEVAC F-Box ‘Override digital’ and ‘Override numeric’ and to manipulate/force the F-Box internal adjust parameters from scada or web page? (FAQ #101980)
  • The special FBox library PCD7_D7 is now available for PG5 2.0. (FAQ #101356)
  • Which PG5 version is compatible with what operating system? (FAQ #100405)

PG5 2.2 / Fupla

  • Why the PG5 2.1, 2.2 or 2.3 update manger application is no more working and it’s not possible to download files from PG5 update manager server? (FAQ #102020)
  • Shall I use PG5 2.3, PG5 2.2, 2.1, 2.0 or PG5 1.4 for my next project? (FAQ #102018)
  • Why after an download of a PG5 2.2.230 project to the PCD, where BACnet revision 14 is used, the application program on the PCD doesn’t work correctly and have a randomly unexpected/unwanted functionality? (FAQ #102013)
  • PG5 2.1 and 2.2 with E-Line S-Bus communication library < 1.2.110, why the S-Bus communication on the master PCD stops either after a certain time? (FAQ #102009)
  • PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or after the download of the program? (FAQ #102008)
  • No Refresh from State of I/O's from E-Line Rio- Moduls after Fbox Update (FAQ #102001)
  • Why does the fupla in PG5 2.2.140 deletes connexions? (FAQ #101996)
  • Why it’s not possible to distribute the corrections (hotfix files) for PG5 over the PG5 update manager? (FAQ #101983)
  • Why in PG5 2.2.130 it's not possible to map in the BACnet Configurator analogue values to PCD medias? (FAQ #101981)
  • On PG5 2.2.130, why it’s no more possible to access from scada or web page to the HEVAC F-Box ‘Override digital’ and ‘Override numeric’ and to manipulate/force the F-Box internal adjust parameters from scada or web page? (FAQ #101980)
  • The special FBox library PCD7_D7 is now available for PG5 2.0. (FAQ #101356)

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

Download