-
PCD3.M6860
-
PCD3 Power-CPU with 2 Ethernet Interface
-
Documentation
Presentation about PCD3.M6860
System Catalogue : PCD3
Extract | 26-215_A0120 | System Catalogue : PCD3 |
PCD3.M6860 - High-performance CPU
Datasheet | PP34-007 | PCD3.M6860 - High-performance CPU |
PCD3 processor unit with 2 Ethernet TCP/IP,
web and FTP server, file system,
CPU with 2 MByte user program,
1 MByte SRam extension memory,
128 MByte user Flash memory with file system,
clock (RTC), data protection 1-3 years,
USB port for PG5, up to 1024 I/O, 2 interrupt inputs,
RS-485 for Profi-S-Net/MPI/S-Bus
ENG01 | 0.37 MB | Download | |||
FRA01 | 0.37 MB | Download | |||
GER01 | 0.37 MB | Download | |||
ITA01 | 0.37 MB | Download |
PCD3 Hardware
Manual | 26-789 | PCD3 Hardware |
File System and FTP Server
IO-Modules
Manual | 27-600 | IO-Modules |
Systemcable and adapter
Manual | 26-792 | Systemcable and adapter |
PCD3.F1xx & PCD3.F2xx - Communication modules
Manual | 26-857 | PCD3.F1xx & PCD3.F2xx - Communication modules |
TCP/IP - Ethernet for the Saia PCD® Serie
Manual | 26-776 | TCP/IP - Ethernet for the Saia PCD® Serie |
TCP/IP-Enhancements
Manual | 26-867 | TCP/IP-Enhancements |
Leaflet: PCD3.M6860
App notes incl. examples PPP, DHCP, DNS and SNTP
Info | Application Notes | App notes incl. examples PPP, DHCP, DNS and SNTP |
Firmware used in production
The actual COSinus FW 1.26.xx or higher for the main CPU and the extension CPU is available from the COSinus firmware page.
Firmware
Update description of the firmware on PCD3.M6860 and PCD3.M6880
Technical Info | Update description of the firmware on PCD3.M6860 and PCD3.M6880 |
EN01 | 0.62 MB | Download |
Remark about the firmware update on PCD3.M6860 or PCD3.M6880 CPU’s can be found on the FAQ 101988
The internal power consumption of systems with PCD3 components can be calculated with PG5 Device Configurator | ||
EPLAN product macros, DWG and DXF files can be found here (the dimensions of the PCD3.Mxx60 are identical to the PCD3.Mxx40) | ||
For printing on the Labeling-Strips for PCD3-Modules please use the Device Configurator from PG5 2.1. |
Good to know
The configuration of the PCD3.M6880 is possible since PG5 2.1.400.
No more possible to set the PCD3.M6860 in to the firmware download mode with the help of the run/stop switch (since booter version 1.24.11)
See FAQ 101948
The configuration of the PCD3.M6860 is possible since PG5 2.1.100.
There is a program example for the PCD3.M6860 available in the Getting Started section.
Application programs are stored in the onboard flash. For this reason, the CPU of the PCD3.M6860 differs in its behaviour regarding program download, backup and restore requirements from existing PCD3 CPUs.
The CPU can remain in run during the download process, but always restarts before deploying the new program (download changed blocks in run is not yet possible).
On the PCD3.M6860, both Ethernet ports are active at the same time (and also active for the Ether S-Bus communication, if activated on the device configurator) regardless of the channel number.
The same behavior does also apply for the S-Bus communication F-Boxes, means that the channel defined in the master/slave F-Box has no effect in the relation to the two Ethernet ports.
USB connector on extension (under blue cover) is not used.
Can only be used for FW download if there is no FW (Booter only). FW download normally goes via USB 1 and Ethernet (1 or 2).
Performance
There are 2 Ethernet interfaces but only one CPU which processes the Ethernet communication -> Ethernet communication performance is not increased
Communication via Ethernet 2 uses (about 2x) more CPU power than communication via Ethernet 1
Communication via Ethernet 2 is slower (about 2x) than via Ethernet 1
If there is heavy communication on both Ethernet interfaces the user program execution is slowed down correspondingly
PCD3 / Mxxx
- How to know whether the circuit board of the PCD is fitted with a Swissbit micro-SD memory card? (FAQ #102070)
- How to copy csv-Files and Webeditorproject files which are stored on the Intflash of a PCD, if you are replacing an internal micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102069)
- What is stored on the micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102068)
- How can the micro SD memory card on the circuit board of a PCD controller be replaced? (FAQ #102067)
- Why are the inputs and outputs of a PCD3 systems not switched on and off correctly, or switched on and off randomly, or the I/O status not detected correctly in the PLC? (FAQ #102063)
- It's possible to connect SBC PCD's directly to the internet? (FAQ #102060)
- What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102058)
- On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052)
- Why on a PCD3.M5/6xxx or a PCD2.M45xx the battery LED is switched on and the battery error message is activated in the application program after a new battery was inserted? (FAQ #102039)
- What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102010)
- Remark about the firmware update on PCD3.M6860 or PCD3.M6880 CPU’s (FAQ #101988)
- What are the differences between the COSinus firmwares FW 1.24.67 and FW 1.26.31? (FAQ #101987)
- It’s possible to suppress the PCD Alarms on BACnet? (FAQ #101975)
- How to configure the analogue inputs of a PCD3.M90 to be able to connect an NTC10k temperature sensor? (FAQ #101974)
- Why it’s no more possible to set the PCD3.Mxx6x in the firmware download mode with the help of the run/stop switch? (FAQ #101948)
- How does the battery / power-up check work on the PCD? (FAQ #101929)
- What are the differences between the COSinus firmwares FW 1.22.48 and FW 1.24.69? (FAQ #101921)
- Why the status overflow flag of the onboard analogue inputs of the PCD1.M0, PCD1.M2, PCD3.M2x30V6 (PCD3 Compact) and PCD3.M2x30A4Tx (PCD3 WAC) does show an over-flow in the middle of the measurement? (FAQ #101864)
- It's possible to connect a Ethernet Port of a PCD directly to Power over Ethernet (PoE)? (FAQ #101847)
- Why is there an offset to the current PCD time in the Trending timestamp of a Web project if the FW 1.20.nn is used? (FAQ #101834)
- What does the history message 'MEMORY LOST n' mean? (FAQ #101830)
- On PCD2.M5 and PCD3 CPU's without Ethernet port and equipped with the FW 1.20.25, it's not possible to communicate over the port 0 and 1. (FAQ #101823)
- What are the differences between firmware 1.16.69 and COSinus FW 1.22.61? (FAQ #101820)
- Why the MPI adapter doesn’t work on the MPI port of the PCD3.M5547, PCD3.M5567, PCD3.M5540, PCD3.M5440 or PCD3.5560? (FAQ #101814)
- On a NT PCD the S-Bus slave gateway port doesn't communicate after programm restart of the gateway PCD! (FAQ #101802)
- Which Texts are writeable/editable during Runtime on a PCD? (FAQ #101801)
- Lifetime expectancy of the Renata Lithium battery on recent PCD compared to previous PCD generations (FAQ #101780)
- How the RS485 bus is terminated if on a PCD3.M5340 the bustermination of the port 3 is activated? (FAQ #101753)
- What is the signification of the history entry "Resisters Fail"? (FAQ #101722)
- Why is the modem "MDLS144 onbit" no longer working on a new PCD? (FAQ #101718)
- Why does the PCD no longer run due to "BNt FAIL AI00006"? (FAQ #101712)
- Why does the user program no longer work correctly after a restore from flash? (FAQ #101680)
- What is the article number of the PCD3.M5/6 onboard battery module? (FAQ #101675)
- Why is it no longer possible to switch on/off the digital outputs of the PCD3.Compact after installing PG5 SP2 (PG5 2.0.200)? (FAQ #101663)
- Why is it no longer possible to switch on/off the relay outputs of the PCD3.WAC after installing PG5 SP2 (PG5 2.0.200)? (FAQ #101659)
- Why I get the error message "NAK response" during a program download (with PG5 SP2)? (FAQ #101656)
- Why has the PCD lost the program while updating the firmware to 1.16.xx? (FAQ #101625)
- What are the differences between firmware 1.14.23 and 1.16.69? (FAQ #101624)
- What for is the "Extension memory backup size" in the Device Configurator used? (FAQ #101623)
- How does the "Backup user program to file system" on PCD3 and PCD2.M5 work? (FAQ #101622)
- Why does the SMS transmission on a PCD3 WAC sometimes fail? (FAQ #101564)
- Why is the "GPRS Status" of the WAA library not always updated? (FAQ #101545)
- Important remark when updating the PCD firmware from 1.10.xx or 1.14.xx to 1.16.xx/1.20.xx (FAQ #101535)
- Why is the USB communication to my PCD lost after a program download? (FAQ #101518)
- What do parameters 'speed' and 'priority' mean which get displayed on the status page of the PCD? (FAQ #101513)
- How to extend the amount of available Flags on a PCD? (FAQ #101447)
- How long does the SuperCap of the PCD3.M3xxx protect the media and RTC from being lost? (FAQ #101426)
- What are the reasons for a "Bus Error" on a PCD2.M5 or a PCD3? (FAQ #101418)
- Firmware dependencies for the "DB Access Library" (FAQ #101372)
- How to configure a Profi-S-I/O network with a PCD3.M2 as master? (FAQ #101367)
- Why are the inputs 8100 and 8101 continously "high" in my fupla file? (FAQ #101363)
- Why is it not possible to choose minimal and maximal value in the device configurator for the PCD3 compact? (FAQ #101311)
- Why can't I add an extension module to my PCD3 compact? (FAQ #101303)
- Why does the PCD go into halt when using temporary data (TEQU)? (FAQ #101293)
- Meaning of the error codes for DB backup to flash (FAQ #101284)
- Why are the DBs not correctly restored after a "restore program from flash"? (FAQ #101279)
- Meaning of the LEDs on Profibus DP Master modules and CPUs (FAQ #101271)
- Is Modbus supported by Saia PCD®s? (FAQ #101270)
- What happens if I use the I/O address 255 as Input or Output of a PCD3? (FAQ #101252)
- Is it possible to use an encoder on PCD3.M2x30V6? (FAQ #101237)
- Can I detect the CTS signal on port 3 of a PCD3.M5340 (in RS422 mode)? (FAQ #101170)
- How to download the configuration of the PCD3.M2xxx (FAQ #101167)
- Is parity mode working on all ports of PCD3 and PCD2.M5 CPU? (FAQ #101103)
- Why it's not possible to use the whole memory of a file system on flash? (FAQ #101082)
- Where can I plug flash memory modules on a PCD3 CPU? (FAQ #101027)
- Why is the port 2 of the PCD3.Mxxx no longer working? (FAQ #101026)
- The PCD3.M6440 is not available in the Hardware Settings (FAQ #100987)
- How to reset a PCD3 system? (FAQ #100954)
- Why does the MAC address shown on the sticker not have 12 digits? (FAQ #100946)
- Why can't I change the Profi-S-Bus address on a PCD3.M6540 Port 2? (FAQ #100941)
- Why is the 1 MB internal flash memory with file system not available on PCD3.M2130V6? (FAQ #100874)
- Is it possible to use the cable PCD2.K106 between PCD3.Mxxxx and PCD2.Cxxx ? (FAQ #100804)
- Why are broadcast telegramms not working anymore on the PCD3 or PCD2.M480 (FAQ #100798)
- What is the article number of the orange 8-pol cage clamp connector (power supply connector) of the PCD3.M3/5 CPU? (FAQ #100789)
- Why is the Port 3 on the PCD3.M5340 not running correctly in RS 485 mode? (FAQ #100765)
- Why can't I connect a PCD3.M5xx0 over the serial PGU port? (FAQ #100737)
- Tool to test if IP ports are blocked by Router of Firewalls (FAQ #100729)
- PCD3.Mxxxx Real Time Clock (RTC) corruption (FAQ #100712)
- Backup and restore Text/DB doesn't work with the SYSWR K 3x00 calls on the onboard Flash of the PCD3? (FAQ #100702)
- Conflict between communication module (PCD3.F1xx) and memory module (PCD3.Rxxx) (FAQ #100636)
- Is it possible to connect non-SBC devices on a Profi S-I/O network? (FAQ #100596)
- Why is the error LED on after having sent an SMS message? (FAQ #100582)
- Userprogram update with PCD7.R500 (FAQ #100515)
- Why does the "Error 335:...Invalid register number" appear on build? (FAQ #100491)
- Where does a "Backup User Program to flash" write the backup? (FAQ #100452)
- Multi protocol functions for Profibus DP, Profi-S-IO and Profi-S-bus using port 10 or port 2 on a PCD3.Mxxxx. (FAQ #100409)
- New systems do not support the baudrates below 1200Baud (FAQ #100394)
- HMI Editor and PCD3.M_ or PCD2.M480: Wrong characters are display instead of value with Format #####! (FAQ #100360)
- Why can't I use registers above 8191 with the Modbus FBox library from Engiby? (FAQ #100354)
- Which subnet masks are allowed for a TCP/IP configuration of a PCD? (FAQ #100318)
- MPI communication on the Profi-S-Net port of a PCD2.M480, PCD2.M5xxx or PCD3.Mxxxx (FAQ #100284)
- Download of the wrong FW to a PCD3 possible (FAQ #100259)
PCD3 / _Firmware Classic
- It's possible to connect SBC PCD's directly to the internet? (FAQ #102060)
- What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102058)
- On a PCD3.M6860 it’s possible to use BACnet on the Ethernet port ETH1 and/or on ETH2? (FAQ #102031)
- Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026)
- PCD Firmware 1.28.16 or 1.24.69 fix the Ethernet frame padding information leakage (FAQ #102011)
- What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102010)
- Lon Bindings lost after power off / on with FW 1.26.15 (FAQ #101999)
- What are the differences between the COSinus firmwares FW 1.24.67 and FW 1.26.31? (FAQ #101987)
- What is the meaning of the PCD history entry ‘FWDnld UnknownFW’? (FAQ #101959)
- MUKE error 100xxxxxH (FAQ #101933)
- How to find more information based on the error message "SF not loaded"? (FAQ #101568)
- What does CSF stand for? (FAQ #101566)
- What are the differences between firmware 1.10.51 and 1.14.23? (FAQ #101470)
- Why can't I send more than 512 bytes using the STXT instruction? (FAQ #101468)
- Can I have more than 16 COBs? (FAQ #101467)
- Why is the error bit 7 or 8 set when I try to execute a "Backup DB to flash"? (FAQ #101466)
- What are the differences between firmware 1.10.16 and 1.10.51? (FAQ #101422)
- How to define a comma as separator in interpreted texts? (FAQ #101392)
- Potential data loss on SD cards bigger than 256 MBytes (FAQ #101377)
- Is the "full duplex" mode supported by the Ethernet ports of a PCD? (FAQ #101365)
- Overview of the current production firmware versions (FAQ #101304)
- What does "Saia PCD® COSinus" stand for? (FAQ #101297)
- How to implement a software watchdog (FAQ #101285)
- Why does the S-I/O communication no longer work on a PCD3 or a PCD2.M5? (FAQ #101244)
- What is the "WebServer2" on Saia PCD® COSinus systems? (FAQ #101191)
- Can I calulate with IEEE floating point values on a PCD system? (FAQ #101188)
- Can I read a value from a PCD text and copy it into a register? (FAQ #101187)
- Is it possible to search an expression within a PCD text? (FAQ #101186)
- The XOB 8 is no longer called on the systems Saia PCD® COSinus. (FAQ #101137)
- Why does the communication on the PCD3.F281 not work? (FAQ #101090)
- Why does a "KRNL ERROR" or a "SWTO Error" occur? (FAQ #101069)
- What criterias are to be fulfilled for sending e-Mails from the PCD? (FAQ #101054)
- Why is the message: "Failed to get data on alarm.exe" displayed on the alarming page? (FAQ #100963)
- Is it possible reading the PCD "IP address" from the user program? (FAQ #100952)
- How does the system watchdog work? (FAQ #100908)
- How to dump the memory of a PCD (with Saia PCD® COSinus firmware)? (FAQ #100833)
- Why are broadcast telegramms not working anymore on the PCD3 or PCD2.M480 (FAQ #100798)
- Why is the Port 3 on the PCD3.M5340 not running correctly in RS 485 mode? (FAQ #100765)
- Download of PCD3 firmware fails on END command (NAK response) (FAQ #100742)
- New firmware version names for Saia PCD® COSinus systems (a.bb.cc) (FAQ #100741)
- Why can't I connect a PCD3.M5xx0 over the serial PGU port? (FAQ #100737)
- PCD3.Mxxxx Real Time Clock (RTC) corruption (FAQ #100712)
- Can I use the character mode with XON/XOFF protocol on NT-PCD's? (FAQ #100700)
- Download of PCD3 firmware fails on END command (no response) (FAQ #100681)
- Download of PCD3 firmware fails with "NAK response" (FAQ #100679)
- Different handling of the TBSY flag (in MC mode) between PCD3 / PCD2.M5 and older systems (FAQ #100655)
- Conflict between communication module (PCD3.F1xx) and memory module (PCD3.Rxxx) (FAQ #100636)
- allowed Firmware for PCD3.M5540 hardware version D (FAQ #100590)
- Intelligent modules aren't correctly detected on HW version older than "D" (FAQ #100549)
- Why is the message: "cannot create page content yet" appears from time to time (FAQ #100527)
- PCD8.K120 doesn't work after FW download to PCD3 (FAQ #100524)
- Why does "Sasi Slave" on Port 1 / 0 (RS232) of the PCD3 generate an error? (FAQ #100420)
- PCD3 problem with "Real TIME CLOCK" Firmware V010 (FAQ #100387)
- lose Hardware settings after Firmware update (FAQ #100366)
- FW depending differences in the handling of the diagnosic flags (FAQ #100321)
- Error LED of PCD is lit! How to find the problem? (FAQ #100269)
- Download of the wrong FW to a PCD3 possible (FAQ #100259)
- What EPROM burner is recommended to create firmware chips for PCD's? (FAQ #100256)
- Firmware version naming of non-Saia PCD® COSinus systems (FAQ #100176)
- Not all History entries can be found in the Online Help of PG5 (FAQ #100173)
- Why is the instruction DSP not supported on Saia PCD® COSinus systems? (FAQ #100034)