-
PCD3.W4xx
-
Analogue output modules 8 bits
Documentation
System Catalogue : PCD2
Extract | 26-215_A0140 | System Catalogue : PCD2 |
PCD2.W400 - Analogue outputs, 4 channels, 8 bits
Datasheet | 31-541 | PCD2.W400 - Analogue outputs, 4 channels, 8 bits |
Manual : PCD2.M5xxx
Manual | 26-856 | Manual : PCD2.M5xxx |
IO-Modules
Manual | 27-600 | IO-Modules |
Systemcable and adapter
Manual | 26-792 | Systemcable and adapter |
PCD1 | PCD2 Hardware
Manual | 26-737 | PCD1 | PCD2 Hardware |
Software / Tools
PCD2 / Wxxx
- Why do measured input values for PCD2.W3x5 / PCD3.W3x5 cards "freeze" (FAQ #102043)
- Why do the output of the PCD2/3.W6x5 not deliver stable signals? (FAQ #102014)
- What is the signification of the I/O words of a PCD2/3.W525 module? (FAQ #101552)
- Why do I get wrong values when reading a PCD2/3.W340 with media mapping? (FAQ #101416)
- A PCD2.W3x0 conflicts with a PCD2.F2xx0 or a PCD2.R6000 on a PCD2.M5xxx (FAQ #101262)
- What exactly is a PCD2/3.W721 and can I order it? (FAQ #101247)
- Why do the outputs of PCD2/3.W525 not work? (FAQ #101204)
- Replacement possibilities for PCD2.W5x0 and PCD3.W5x0 modules (FAQ #101151)
- What is the IL code needed for the PCD2/3.W525 cards? (FAQ #101080)
- Replacement possibilities for PCD2.W1xx modules (FAQ #101033)
- Which module to use for Pt100 / Ni100 measurements? (FAQ #101032)
- Connecting "special" temperature sensors to analogue modules. (FAQ #100926)
- Why is the range of analogue (current-) input modules specified as 0(4)..20 mA? (FAQ #100675)
- Analogue modules read wrong values while beeing online with PG5 (FAQ #100631)
- Shall the terminal 16 of the PCD2/3.W745 be connected to ground? (FAQ #100604)
- What is the reason for the error "underflow" of the PCDx.W745? (FAQ #100499)
- Frozen PCD2/3.W3x5 and PCD2/3.W6x5 modules (FAQ #100475)
- Sampling time of PCD2/3.W6x5 modules (FAQ #100395)
PCD2 / M5xxx
- On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052)
- Why the PCD2.C1000 and the PCD2.C2000 with production date calendar week 20 to 36 of the year 2021 does not work well? (FAQ #102051)
- Why do the output of the PCD2/3.W6x5 not deliver stable signals? (FAQ #102014)
- Inputs of a W525 could be perturbed from an other input? (FAQ #102007)
- What are the differences between the COSinus firmwares FW 1.24.67 and FW 1.26.31? (FAQ #101987)
- MUKE error 100xxxxxH (FAQ #101933)
- What are the differences between the COSinus firmwares FW 1.22.48 and FW 1.24.69? (FAQ #101921)
- How many onboard I/O are available on a PCD2.M5x40? (FAQ #101907)
- Can the PCD7.R610 SD card memory be used on any PCD device? (FAQ #101890)
- It's possible to connect a Ethernet Port of a PCD directly to Power over Ethernet (PoE)? (FAQ #101847)
- Why is there an offset to the current PCD time in the Trending timestamp of a Web project if the FW 1.20.nn is used? (FAQ #101834)
- On PCD2.M5 and PCD3 CPU's without Ethernet port and equipped with the FW 1.20.25, it's not possible to communicate over the port 0 and 1. (FAQ #101823)
- What are the differences between firmware 1.16.69 and COSinus FW 1.22.61? (FAQ #101820)
- On a NT PCD the S-Bus slave gateway port doesn't communicate after programm restart of the gateway PCD! (FAQ #101802)
- Why is the modem "MDLS144 onbit" no longer working on a new PCD? (FAQ #101718)
- Why does the PCD no longer run due to "BNt FAIL AI00006"? (FAQ #101712)
- Why does the user program no longer work correctly after a restore from flash? (FAQ #101680)
- Why does the PCD7.F7500 does not work on the PCD2.M5540? (FAQ #101655)
- Why has the PCD lost the program while updating the firmware to 1.16.xx? (FAQ #101625)
- What are the differences between firmware 1.14.23 and 1.16.69? (FAQ #101624)
- What for is the "Extension memory backup size" in the Device Configurator used? (FAQ #101623)
- How does the "Backup user program to file system" on PCD3 and PCD2.M5 work? (FAQ #101622)
- Important remark when updating the PCD firmware to 1.16.xx (FAQ #101587)
- Important remark when updating the PCD firmware from 1.10.xx or 1.14.xx to 1.16.xx/1.20.xx (FAQ #101535)
- Why is the USB communication to my PCD lost after a program download? (FAQ #101518)
- What do parameters 'speed' and 'priority' mean which get displayed on the status page of the PCD? (FAQ #101513)
- Which hardware revision of the PCD2.M5_ is needed for firmware 1.14.23? (FAQ #101490)
- Why do I get IP communication errors from time to time on a PCD2.M554x? (FAQ #101473)
- How to extend the amount of available Flags on a PCD? (FAQ #101447)
- What are the reasons for a "Bus Error" on a PCD2.M5 or a PCD3? (FAQ #101418)
- Why does the PCD2.R6000 not work if a PCD2.C2000 is used on the same system? (FAQ #101414)
- Firmware dependencies for the "DB Access Library" (FAQ #101372)
- Is the "full duplex" mode supported by the Ethernet ports of a PCD? (FAQ #101365)
- Why are the inputs 8100 and 8101 continously "high" in my fupla file? (FAQ #101363)
- Why does the PCD go into halt when using temporary data (TEQU)? (FAQ #101293)
- Meaning of the error codes for DB backup to flash (FAQ #101284)
- Why are the DBs not correctly restored after a "restore program from flash"? (FAQ #101279)
- Is Modbus supported by Saia PCD®s? (FAQ #101270)
- A PCD2.W3x0 conflicts with a PCD2.F2xx0 or a PCD2.R6000 on a PCD2.M5xxx (FAQ #101262)
- If I do change the TCP/IP settings of the PCD2.M5 CPU with the eDisplay (PCD7.D3100E), when are the new TCP/IP settings are activated? (FAQ #101168)
- Is parity mode working on all ports of PCD3 and PCD2.M5 CPU? (FAQ #101103)
- Is it possible to use two different TCP/IP addresses for the two TCP/IP connectors of the PCD2.M5 CPU? (FAQ #101097)
- Why do the onboard outputs on a PCD2.M5xxx not work? (FAQ #100944)
- Why doesn't my CPU go in RUN after download, even if this download option has been activated? (FAQ #100942)
- On the Profibus-DP or Profi-S-I/O master it isn't possible to read or write registers with address > 4095 from the slave (FAQ #100927)
- What is the minimum distance between PCD2.Mxxx CPUs and PCD2.C1xx extension rack? (FAQ #100892)
- How to dump the memory of a PCD (with Saia PCD® COSinus firmware)? (FAQ #100833)
- RTS and CTS signs are crossed on Slot A#1 and A#2 (Hardware Version A and Prototypes) of the PCD2.M5540 (FAQ #100831)
- Can I use the character mode with XON/XOFF protocol on NT-PCD's? (FAQ #100700)
- Why does a PCD7.F120 not work when used on a PCD3 or a PCD2.M5? (FAQ #100646)
- Is it possible to download an xx7 firmware to a classic PCD and invers? (FAQ #100557)
- Why does the "Error 335:...Invalid register number" appear on build? (FAQ #100491)
- New systems do not support the baudrates below 1200Baud (FAQ #100394)
- MPI communication on the Profi-S-Net port of a PCD2.M480, PCD2.M5xxx or PCD3.Mxxxx (FAQ #100284)
- PCD7.D7xx terminal works on PGU port of PCD2.M110 but not on PGU port of PCD2.M150! (FAQ #100188)
- Why the LED's of the Profi-S-Link adapter (PCD8.K120) are not switched on? (FAQ #100177)
PCD2 / M1xx
- On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052)
- Why do the output of the PCD2/3.W6x5 not deliver stable signals? (FAQ #102014)
- Why is the modem "MDLS144 onbit" no longer working on a new PCD? (FAQ #101718)
- Until when can a PCD2.M120 be reparied? (FAQ #101482)
- Why do I get a "DUART HW ERROR" on PCD2.M150 after restart? (FAQ #101395)
- Why does the IP communication not work with firmware 0F0? (FAQ #101384)
- Why does my PCD1 no longer start (due to a "Text segment error") after downloading a project with PG5 2.0? (FAQ #101379)
- Firmware dependencies for the "DB Access Library" (FAQ #101372)
- Meaning of the error codes for DB backup to flash (FAQ #101284)
- Is Modbus supported by Saia PCD®s? (FAQ #101270)
- "Send SMS extended" FBox and PCD1.M1x0 and PCD2.M110/120 (FAQ #101163)
- RAM chip types to be used as user memory on a PCD1.M1xx or PCD2.M1xx (FAQ #101100)
- What is the minimum distance between PCD2.Mxxx CPUs and PCD2.C1xx extension rack? (FAQ #100892)
- Is possible to use two TCP/IP modules on a PCD CPU? (FAQ #100785)
- Firmware download on a PCD2.M150 (FAQ #100598)
- Is it possible to download an xx7 firmware to a classic PCD and invers? (FAQ #100557)
- Can I use the same GSD File for PCD2.M170 as for PCD4.M170 (FAQ #100412)
- Functional limitation regarding the use of the modem library (FAQ #100392)
- PCD2.M170 or PCS1: WEB Server works only if a WEB project is downloaded in the PCD! (FAQ #100380)
- Which Flash chip to use for which usage? (FAQ #100309)
- PCD2.M150F650: Cannot go online via TCP/IP (FAQ #100270)
- What is the max. size of DBs/TEXTs in the extension memory of PCD2.M170/480 with a PCD7.R400 memory module? (FAQ #100266)
- Software Watchdog mustn't be used with FW 0C1 on PCD2.M150! (FAQ #100218)
- Firmware version for PCD7.F650 and PCD2.M480 (FAQ #100189)
- PCD7.D7xx terminal works on PGU port of PCD2.M110 but not on PGU port of PCD2.M150! (FAQ #100188)
- Corrupted Flash user memory makes writing HW settings or program impossible (FAQ #100146)
- "COM O 255" for Watchdog on a system with PCD3.Cxxx might cause problems (FAQ #100101)
PCD2 / M48x
- On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052)
- Why do the output of the PCD2/3.W6x5 not deliver stable signals? (FAQ #102014)
- Can I use the PCD2.M480 as an IP Router for Ether-S-Bus communication or as an IP Firewall? (FAQ #101597)
- Why does the S-Bus gateway no longer work after some time? (FAQ #101393)
- Firmware dependencies for the "DB Access Library" (FAQ #101372)
- Meaning of the error codes for DB backup to flash (FAQ #101284)
- Is Modbus supported by Saia PCD®s? (FAQ #101270)
- Why doesn't my CPU go in RUN after download, even if this download option has been activated? (FAQ #100942)
- On the Profibus-DP or Profi-S-I/O master it isn't possible to read or write registers with address > 4095 from the slave (FAQ #100927)
- What is the minimum distance between PCD2.Mxxx CPUs and PCD2.C1xx extension rack? (FAQ #100892)
- Why are broadcast telegramms not working anymore on the PCD3 or PCD2.M480 (FAQ #100798)
- Is possible to use two TCP/IP modules on a PCD CPU? (FAQ #100785)
- Not possible to go on line a 2nd time over a PGU connection (on the port 0 D-Sub connector)! (FAQ #100761)
- PCD2.M480 FW 025: Not possible to go on line when Webserver is connected! (FAQ #100652)
- Why does a PCD7.F120 not work when used on a PCD3 or a PCD2.M5? (FAQ #100646)
- Is it possible to download an xx7 firmware to a classic PCD and invers? (FAQ #100557)
- Is it possible to use the S-Net MPI port as free RS 485 port on the PCD2.M480? (FAQ #100530)
- Why does the "Error 335:...Invalid register number" appear on build? (FAQ #100491)
- PCD2.M48x Real Time Clock (RTC) corruption (FAQ #100447)
- New systems do not support the baudrates below 1200Baud (FAQ #100394)
- S-Bus Slave on Port 3 doesn't work with FW 020 on the M480 (FAQ #100389)
- HMI Editor and PCD3.M_ or PCD2.M480: Wrong characters are display instead of value with Format #####! (FAQ #100360)
- Supported baudrates and protocols on a PCD2.M480 (FAQ #100355)
- PCD2.M480: minimum firmware version for USB, Profi-S-Bus, Profi-S-IO, Multiple S-Bus PGU Ports (FAQ #100340)
- Is the MPI communication starting without configuration on the M480? (FAQ #100327)
- MPI communication on the Profi-S-Net port of a PCD2.M480, PCD2.M5xxx or PCD3.Mxxxx (FAQ #100284)
- PCD2.M150F650: Cannot go online via TCP/IP (FAQ #100270)
- What is the max. size of DBs/TEXTs in the extension memory of PCD2.M170/480 with a PCD7.R400 memory module? (FAQ #100266)
- PCD2.M480: The communication doesn't work on the Master Gateway Port! (FAQ #100192)
- Firmware version for PCD7.F650 and PCD2.M480 (FAQ #100189)
- PCD7.D7xx terminal works on PGU port of PCD2.M110 but not on PGU port of PCD2.M150! (FAQ #100188)
- PCD2.M480: SM1 (S-Bus Master Parity) on Port 1 is not supported! (FAQ #100186)
- Why the LED's of the Profi-S-Link adapter (PCD8.K120) are not switched on? (FAQ #100177)
- "COM O 255" for Watchdog on a system with PCD3.Cxxx might cause problems (FAQ #100101)