About Saia PCD Supervisor
SBC’s scalable software platform Saia PCD Supervisor monitors and controls simple HVAC controls as well as enterprise-wide control stations of major building complexes or infrastructure installations. Open communication standards enable the integration of external systems. The easy handling of Saia PCD devices ensures efficient system management, as well as a high operating comfort through the customizable user interface, dedicated dashboards and a remote Function.
Saia PCD Supervisor is based on the Niagara 4.13u2 platform from Tridium.
This software core has been used successfully worldwide for many years. Compared to the standard version of Tridium, our Saia PCD Supervisor includes, among other advanced BACnet Utilities, an Ether-S-Bus driver, the PG5 Icon Gallery and a PG5 Data Import Wizard for easy and fast integration of Saia PCD controllers.
Documents
System Catalogue : Saia PCD® Supervisor
Extract | 26-215_B0121 | System Catalogue : Saia PCD® Supervisor |
Saia PCD® Supervisor
Brochure | 31-703 | Saia PCD® Supervisor |
Saia PCD® Supervisor
Flyer | 31-061 | Saia PCD® Supervisor |
Saia PCD® Supervisor
Datasheet | 34-001 | Saia PCD® Supervisor |
Saia PCD® Supervisor,
is a building monitoring and management solution built upon the powerful Niagara platform.
It is capable of integrating Saia PCD® controllers, third party devices and internet protocols into a centralised software platform that is designed to manage buildings at an enterprise level.
ENG08 |
![]() |
1.01 MB | Download |
Saia PCD® Supervisor
Manual | 27-651 | Saia PCD® Supervisor |
Saia PCD® Supervisor - Large Scale Systems
Brochure | 31S708 | Saia PCD® Supervisor - Large Scale Systems |
Saia PCD® Supervisor
Guidance for Large Scale Systems
When specifying Saia PCD® Supervisor for use with larger BEMS sites or multiple sites it is important to configure the system correctly, in order to provide optimum system performance. This document provides best practice guidance on assessing performance criteria, choosing the appropriate hardware (system architecture) and techniques for configuring Saia PCD® Supervisor in large scale systems.
ENG02 |
![]() |
1.13 MB | Download | ||
FRA02 |
![]() |
1.14 MB | Download | ||
GER02 |
![]() |
1.14 MB | Download | ||
ITA02 |
![]() |
1.13 MB | Download | ||
SPA02 |
![]() |
1.13 MB | Download |
Saia PCD® Supervisor - Easy Templating
Manual | 41-00001-01 | Saia PCD® Supervisor - Easy Templating |
Saia PCD® Supervisor - Easy Binding
Manual | 41-00002-01 | Saia PCD® Supervisor - Easy Binding |
Installation & Operations Guide:
Saia PCD® Supervisor - Easy Binding
ENG - V4.11 |
![]() |
4.93 MB | Download |
Saia PCD® Supervisor - Easy Database Manager
Manual | 41-00003-01 | Saia PCD® Supervisor - Easy Database Manager |
Installation & Operations Guide:
Saia PCD® Supervisor - Easy Database Manager
ENG - V4.11 |
![]() |
3.37 MB | Download |
Saia PCD® Supervisor - Point List Widget
Manual | 41-00004-01 | Saia PCD® Supervisor - Point List Widget |
Saia PCD® Supervisor - Easy Alarm Management
Manual | 41-00005-01 | Saia PCD® Supervisor - Easy Alarm Management |
Installation & Operations Guide:
Saia PCD® Supervisor - Easy Alarm Management
ENG - V4.11 |
![]() |
2.71 MB | Download |
Saia PCD® Supervisor - Easy Healthy Building
Manual | 41-00006-01 | Saia PCD® Supervisor - Easy Healthy Building |
Installation & Operations Guide:
Saia PCD® Supervisor - Easy Healthy Building
ENG - V4.11 |
![]() |
7.01 MB | Download |
Saia PCD® Supervisor - E-Signature Application
Datasheet | 41-00009-01 | Saia PCD® Supervisor - E-Signature Application |
Saia PCD® Supervisor - AlarmtextAssigner
Manual | 27-677 | Saia PCD® Supervisor - AlarmtextAssigner |
Saia PCD® Supervisor - FindSymbolsAndMacros
Manual | 26-658 | Saia PCD® Supervisor - FindSymbolsAndMacros |
Saia PCD® Supervisor - Security Manual
Manual | 26-624 | Saia PCD® Supervisor - Security Manual |
Securing Saia PCD® Supervisor
The purpose of this manual is to provide the information necessary for those involved in the installation and maintenance of a product or system to understand the requirements for configuring and managing the security of the product or system.
ENG04 |
![]() |
0.87 MB | Download | ||
FRA04 |
![]() |
0.91 MB | Download | ||
GER04 |
![]() |
0.90 MB | Download | ||
ITA04 |
![]() |
0.90 MB | Download |
Software installer
Actual release
Saia PCD Supervisor V4.14
Software Release Bulletin
Brochure | V 4.14 | Software Release Bulletin |
Saia PCD Supervisor Software Release Bulletin
V 4.14.0.162.2 |
![]() |
0.83 MB | Download |
Saia PCD Supervisor V4.13u2
Readme
Readme | V 4.13u2 | Readme |
Software Release Bulletin
Brochure | V 4.13u2 | Software Release Bulletin |
Saia PCD Supervisor Software Release Bulletin
V 4.13.2.18.1.2 |
![]() |
1.09 MB | Download |
Tridium release notes
History Document | V 4.13 | Tridium release notes |
Release notes from Tridium for Niagara 4.13u2
V 4.13 |
![]() |
0.27 MB | Download |
Long term support release
Saia PCD Supervisor V4.10u8
Readme
Readme | V 4.10u8 | Readme |
Software Release Bulletin
Brochure | V 4.10u8 | Software Release Bulletin |
Saia PCD Supervisor Software Release Bulletin
V 4.10.8.22.1 |
![]() |
0.91 MB | Download |
Tridium release notes
History Document | V 4.10 | Tridium release notes |
Release notes from Tridium for Niagara 4.10
![]() |
0.65 MB | Download |
Additional tools & modules
For all versions
honUtilityIntTime point extension
Software | V 3.0 | honUtilityIntTime point extension |
To use the honUtilityIntTime Version 4.7.110.32.3.0 (or newer), the datapoint which get extended with the "Int Time Conversion" must be prepared as followed:
- Conversion must be: "SbcLinearConversion" Scale: "1.0"
- precision = "0"
- Fallback Value of "0" is needed for "Reset" functionality
V 4.7.110.32.3.0 |
![]() |
.zip | 0.08 MB | Download | |
Revision history |
![]() |
.txt | 0.00 MB | Download |
Find symbols and macros
Software | V 2.5.4 | Find symbols and macros |
Tool which create a .svm file from a PG5 project.
The .svm file contains PG5 symbols and is used from Saia PCD Supervisor
Quick start document is integreated on the .zip file
Version information:
Version 2.5.4
Fix issue on missing and messed up lists of symbols in Device-Name.csv file.
This could occur if for the same Fupla FBox, outputs from different PG5 symbol groups have been used.
Find symbols and macros V 2.5.4 |
![]() |
.zip | 0.62 MB | Download |
AlarmtextAssigner
Software | V 2.1 | AlarmtextAssigner |
AlarmTextAssiger version 4.6.0.0.0.1
Tool for integration of the alarm texts used in the Saia PG5 project (DDC_Alarming.csv) into the Saia PCD Supervisor.
The AlarmTextAssigner can be used with PG5 projects that were created with Advanced Alarming.
See manual 27-677
No support will be granted from SBC for this module.
V 4.6.0.0.0.1 |
![]() |
.zip | 0.02 MB | Download |
Change Version Toolkit
Software | V 1.7.0 | Change Version Toolkit |
The Change Version Toolkit is a desktop application designed to switch and manage different versions of the Saia PCD Supervisor.
During the development of the Saia PCD Supervisor application, sometimes it's needed to switch between different versions of the Saia PCD Supervisor and to access different tools, folders and settings.
This application is designed to easily support the handling of the Saia PCD Supervisor in different versions.
It can install/uninstall, detect, monitor and manage the state of the Windows based service daemon for different versions and installations.
The tool supports hotkeys for the most commonly used features and directories.
It also provides a supportive and easy way to adjust the heap of the Java runtime of the Saia PCD Supervisor which is always specifically necessary depending on the project and available resources.
V 1.7.0 |
![]() |
100.3 MB | Download |
For version 4.14
For version 4.13u2
VykonPro_Pack-4.13u2
Software | V 4.13u2 | VykonPro_Pack-4.13u2 |
Driver Pack
Software | V 4.13u2 | Driver Pack |
Includes modules for Micros and KNX IP Driver
V 4.13.2.2 |
![]() |
.zip | 5.27 MB | Download |
Optimizer Unitary Tools
Software | 4.13u2 | Optimizer Unitary Tools |
Optimizer Unitary Tools - jar modules supporting PCD supervisor version 4.13u2
2.11.0.7 |
![]() |
.zip | 45.54 MB | Download |
Optimizer Advanced Tools
Software | V 4.13u2 | Optimizer Advanced Tools |
Optimizer Advanced Tools - jar modules and controller template for version 4.13u2
V 4.13u2 |
![]() |
771.4 MB | Download |
For version 4.10u8
Optimizer Unitary Tools
VykonPro_Pack-4.10u8
Driver Pack
Software | V 4.10u8 | Driver Pack |
Includes modules for Micros and KNX IP Driver
V 4.10.8.2 |
![]() |
.zip | 9.93 MB | Download |
Demonstration project
Saia PCD Supervisor demo web page
Sales Support | Saia PCD Supervisor | Saia PCD Supervisor demo web page |
Demonstration page created with the Saia PCD Supervisor.
To display the application use the 'Google Chrome' web browser.
If other browsers are used then not all features of the Saia PCD Supervisor will be avilable.
The demonstration can be accessed with 2 different users:
User 1:
Username: demo
Password: Honeywell1!
Features: Standard demo access and first level authentication for changing data points which are configured as secure data points (E-Signature feature)
User 2:
Username: demoDA (E-Signature)
Password: Honeywell1!
Features: Standard demo access and second level authentication for changing data points which are configured as secure data points (E-Signature feature)
![]() |
Download |
BACnet certificate

BACnet BTL certificates (by WSPCert)
Link to the BACnet certification of BACnet International (BIG-INT)

Software (except PG5) / Saia PCD Supervisor
-
How to exchange .jar files on the Niagara supervisor installation like Saia PCD Supervisor or IQVision or Optimizer Suite or Arena NX? (FAQ #102066)
If you need to update the .jar files on the Niagara supervisor software, perform the following steps:
1. Make sure that you have a file with a .jar extension.
If you got a zip file, extract first the .jar files.2. Copy the .jar files to the following directory:
C:\Brand\Software-Name-Version\modules (example: C:\SBC\SaiaPCDSupervisor-4.12.0.156\modules)3. Open console.exe from C:\Brand\Software-Name-Version\bin and type:
- plat uninstalldaemon followed by pressing the "Return" button
Console should respond with "uninstalldaemon: Niagara service successfully removed." - plat installdaemon followed by pressing the "Return" button
Console should respond with "installdaemon: Niagara service successfully installed.
installdaemon: Niagara service startup initiated."
4. Open the Workbench
Hint:
Make sure to perform the steps in the correct directories.
If a different version of Niagara is running, which you would like to update, quit this version first, before starting the update procedure.
To verify the running Niagara Daemon version, open Windows Task Manager and switch to Services tab:
1. Locate Niagara Service (press "N" to jump fast down the list) and right click on the service.
2. Choose "go to details".
3. In Details tab right click on Niagarad.exe and open the properties
4. Check the given location for Niagarad.exe, for example:
- plat uninstalldaemon followed by pressing the "Return" button
-
On the Saia PCD Supervisor, why does my newly created Easy Template overlap other templates and is not transparent? (FAQ #102065)
An Easy Template is a collection of graphical elements on a px page.
There are standard options available how px files represent themselves.
The user can decide to have either an overlapping template or a transparent one.Depending on the property viewportBackground selection on Scroll Panes the template can be change its behavior.
While leaving it on "default" it will be overlapping another element.
Setting it to "transparent" will not overlap other elements.
Scroll Pane with default settings:
Example:
Scroll Pane with transparent settings:
Example:
-
It's possible to connect SBC PCD's directly to the internet? (FAQ #102060)
Yes it’s possible to connect a PCD directly to the internet, but you have to protect your PCD against unauthorised access or cyber-attacks.
To protect the PCD against unauthorised access or cyber-attacks, it’s imperatively needed to take some protective measures.
Information about protective measures can be found on the support hp
If you need a PCD with cyber security levels SL3+ and based on ANSI ISA 62443 then checkout our PCD3.M6893 (QronoX PCD), this PCD was developed for cybersecure applications.
Information's can be found here.
-
Why on the Saia PCD Supervisor, after an automatic logout or a restart of the server, the last displayed page is shown without the DeviceTemplate menu when logging in again? (FAQ #102057)
Problem
In relation with the DeviceTemplate, there can be a problem on the Saia PCD Supervisor, which occurs after an automatic logout, a restart of the station or a restart of the web server.
In this case only the last visited page is displayed, but without the DeviceTemplate menu
The reason for this is, that the Niagara web server sets a cookie called "niagara_origin_uri" with the latest visited ord.
This cookie is valid until page is closed or reloaded. he deviceTemplate cannot prevent this from happening.
The problem occurs in all Saia PCD Supervisor versions.
Depending on the last visited page and the settings in the supervisor, the image may look like this or similar:
Correct it looks like this:
Workaround
The "niagara_origin_uri" is not set if Same Site option is configured to "none" in a Secure context (HTTPS).
Niagara
1. Go to "Station -> Config -> Services -> WebService".
2. Set the Option "Same Site" to "None".
3. And make sure that HTTPS is active
Browser
1. Clear all cookies at least for the Niagara webpage.
Note:
You must connect via HTTPS to the Niagara-Webserver, if not the solution may not work or the page may not work at all. (May depend from the browser).This will only work with the following Browser versions (or newer versions):
PC:
- Google Chrome 80
- Edge 86
- Firefox 69 (See note below)
- Internet Explorer (Not supported!)
- Opera 71
- Safari (Not supported!)
Mobil:
- WebView Android 80
- Chrome Android 80
- Firefox Android (Not supported!)
- Opera Android 60
- Safari auf iOS (Not supported!)
- Samsung Internet 13
Note:
Firefox for PC has not yet the option "Secure required" for the "SameSite=None" attribute by default (will be default in the future).
1. It need to be configured by typing "about:config" into the address bar
2. Search for "SameSite"
3. Set "network.cookie.sameSite.laxByDefault" to true.
4. Set "network.cookie.sameSite.noneRequireSecure" to true.
-
Are devices or software developed from Saia-Burgess Controls affected by the Domain Name System (DNS) vulnerabilities, published with the report name NAME:WRECK? (FAQ #102046)
No
Saia-Burgess Controls devices and software are not affected from Domain Name System (DNS) vulnerabilities published with the report name NAME:WRECK
-
-
Are SBC devices affected by the zero-day vulnerabilities ‘Ripple20’, related to the low-level TCP/IP software library developed by Treck, Inc.? (FAQ #102036)
No, SBC devices are not affected from the Ripple20 zero-day vulnerabilities since none of our products uses the TCP/IP software library developed by Treck, Inc.
-
Which operating systems and relational database servers are supported for Saia-PCD Supervisor installations? (FAQ #102025)
The Saia-PCD Supervisor runs on:
- Windows 10 (32-bit)
- Windows 10 (64-bit)
- Windows 8.1 Professional/Enterprise/Ultimate (32-bit)
- Windows 8.1 Professional/Enterprise/Ultimate (64-bit)
- Windows 7 Professional/Enterprise/Ultimate (32-bit)
- Windows 7 Professional/Enterprise/Ultimate (64-bit)
- Windows Server 2012 R2 Standard/Enterprise (SP2) (64-bit)
and supports
- MS SQL Server 2016
Detailed overview about the supported operating systems and relational database servers for Saia-PCD Supervisor installations can be loaded over the following link:
On the Niagara article, for the Saia-PCD Supervisor version 1, check the column with header line N4.3
On the Niagara article, for the Saia-PCD Supervisor version 1.1, check the column with header line N4.4
-
It’s possible to display the texts on the Saia PCD Supervisor in different languages? (FAQ #102019)
Yes it’s possible to display the texts for the operator of the Saia PCD Supervisor in English, German or French.
Please note, that only the texts for the operator will be displayed in German or French, but the texts for the developer will be still in English.More information can be found on the support homepage of the Saia PCD Supervisor.
-
Why after the crash of the PC the platform daemon for the Saia PCD Supervisor doesn’t restart automatically? (FAQ #102012)
If the PC where Saia PCD Supervisor is running, was powered off without shutting down the Saia PCD Supervisor then it’s possible that after power on of the PC, the platform daemon used from Saia PCD Supervisor will not start automatically during system restart.
It’s necessary to start the platform daemon for the Saia PCD Supervisor manually.
The attempt to start the daemon via a batch script didn't work either.A modification on the registry could solve the problem.
Solution:
The problem is not in relation with the platform daemon used from the Saia PCD Supervisor but it’s a problem in relation of the Windows internal timings between window services.To solve the problem, the following modifications on the registry entry of the concerned PC should be done.
Make the following steps:
1.
In Windows, go to Start > Run > and type regedit
2.
Navigate to: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
3.
With the control folder selected, right click in the pane on the right and select new DWORD Value
4.
Name the new DWORD: ServicesPipeTimeout
5.
Right-click ServicesPipeTimeout, and then click Modify
6.
Click Decimal, type '180000', and then click OK
7.
Restart the computer
If this in insufficient, try setting to 300000
Honeywell devices
-
How to exchange .jar files on the Niagara supervisor installation like Saia PCD Supervisor or IQVision or Optimizer Suite or Arena NX? (FAQ #102066)
If you need to update the .jar files on the Niagara supervisor software, perform the following steps:
1. Make sure that you have a file with a .jar extension.
If you got a zip file, extract first the .jar files.2. Copy the .jar files to the following directory:
C:\Brand\Software-Name-Version\modules (example: C:\SBC\SaiaPCDSupervisor-4.12.0.156\modules)3. Open console.exe from C:\Brand\Software-Name-Version\bin and type:
- plat uninstalldaemon followed by pressing the "Return" button
Console should respond with "uninstalldaemon: Niagara service successfully removed." - plat installdaemon followed by pressing the "Return" button
Console should respond with "installdaemon: Niagara service successfully installed.
installdaemon: Niagara service startup initiated."
4. Open the Workbench
Hint:
Make sure to perform the steps in the correct directories.
If a different version of Niagara is running, which you would like to update, quit this version first, before starting the update procedure.
To verify the running Niagara Daemon version, open Windows Task Manager and switch to Services tab:
1. Locate Niagara Service (press "N" to jump fast down the list) and right click on the service.
2. Choose "go to details".
3. In Details tab right click on Niagarad.exe and open the properties
4. Check the given location for Niagarad.exe, for example:
- plat uninstalldaemon followed by pressing the "Return" button
Honeywell devices / UN-RxxxNMC: Saia PCD Supervisor programmable room controller
-
How to exchange .jar files on the Niagara supervisor installation like Saia PCD Supervisor or IQVision or Optimizer Suite or Arena NX? (FAQ #102066)
If you need to update the .jar files on the Niagara supervisor software, perform the following steps:
1. Make sure that you have a file with a .jar extension.
If you got a zip file, extract first the .jar files.2. Copy the .jar files to the following directory:
C:\Brand\Software-Name-Version\modules (example: C:\SBC\SaiaPCDSupervisor-4.12.0.156\modules)3. Open console.exe from C:\Brand\Software-Name-Version\bin and type:
- plat uninstalldaemon followed by pressing the "Return" button
Console should respond with "uninstalldaemon: Niagara service successfully removed." - plat installdaemon followed by pressing the "Return" button
Console should respond with "installdaemon: Niagara service successfully installed.
installdaemon: Niagara service startup initiated."
4. Open the Workbench
Hint:
Make sure to perform the steps in the correct directories.
If a different version of Niagara is running, which you would like to update, quit this version first, before starting the update procedure.
To verify the running Niagara Daemon version, open Windows Task Manager and switch to Services tab:
1. Locate Niagara Service (press "N" to jump fast down the list) and right click on the service.
2. Choose "go to details".
3. In Details tab right click on Niagarad.exe and open the properties
4. Check the given location for Niagarad.exe, for example:
- plat uninstalldaemon followed by pressing the "Return" button