PCD1.F2611-C15
-
E-Line DALI module + aux. RS-485
-
E-Line DALI module
freely programmable
for up to 64 DALI ballasts
with integrated DALI-Bus power supply
Supply 24 VAC/VDC
4 digital inputs 24 VAC/VDC
4 interfaces: RS-485 (S-Bus), auxiliary RS-485, USB & NFC (Service)
Documentation
System Catalogue : E-Line
Extract | 26-215_A0160 | System Catalogue : E-Line |
System Catalogue : Room Automation
Extract | 26-215_B0400 | System Catalogue : Room Automation |
Room automation is a crucial component for room comfort and also reduces operating costs to efficient levels. Energy efficiency therefore plays a vital role along with a comfortable interior temperature and the intuitive operation of the various room functions.
This can be achieved by room automation from SBC.
ENG18 |
![]() |
2.44 MB | Download | ||
FRA18 |
![]() |
2.45 MB | Download | ||
GER18 |
![]() |
2.45 MB | Download | ||
ITA18 |
![]() |
2.43 MB | Download |
E-Line-Room-Control
Flyer | PP31-026 | E-Line-Room-Control |
PCD1.F2611-C15 E-Line DALI module and RS-485
Datasheet | PP31-112 | PCD1.F2611-C15 E-Line DALI module and RS-485 |
E-Line DALI module and auxillary RS-485.
The freely programmable module with a housing width of 35 mm (2 HP) can be controlled via RS-485 and enable the direct control of 64 DALI subscribers.
ENG04 |
![]() |
1.33 MB | Download | ||
FRA04 |
![]() |
1.33 MB | Download | ||
GER04 |
![]() |
1.34 MB | Download | ||
ITA04 |
![]() |
1.33 MB | Download |
E-Line Programmable Quick Start
--> More infos about DALI available on our communication support page.
Minimal Firmware configuration
The minimum Firmware for the head station is 1.24.XX
Firmware used in production
Firmware used in production PCD1.E-Line programmable modules and RIO I/O modules
Firmware Package | 1.04.24/1.08.06/1.08.13 | Firmware used in production PCD1.E-Line programmable modules and RIO I/O modules |
This firmware is used in the PCD production and the PCD1 E-Line programmable modules and RIO I/O modules L-Series and S-Seires are shipped with this firmware.
The programmable I/O modules:
FW 1.04.24
PCD1.G1100-C15
PCD1.G360x-C15
PCD1.F2611-C15
PCD1.W5300-C15
The RIO modules L-Series:
FW 1.08.06
PCD1.B1000-A20
PCD1.B1010-A20
PCD1.B1020-A20
PCD1.G5000-A20
PCD1.G5010-A20
PCD1.G5020-A20
The RIO modules S-Series:
FW 1.08.13
PCD1.A1000-A20
PCD1.A2000-A20
PCD1.B5000-A20
PCD1.B5010-A20
PCD1.E1000-A20
PCD1.G2000-A20
PCD1.G2100-A20
PCD1.G2200-A20
PCD1.W5200-A20
1.04.24/1.08.06/1.08.13 |
![]() |
.zip | 0.57 MB | Download |
Good to know

The differences between firmware version 1.04.07 and 1.04.24 are listed in FAQ 101990
Good to know
PG5 2.1.410 or later is to be used for working with the PCD1 E-Line
PCD1 / E-Line
- How to copy csv-Files and Webeditorproject files which are stored on the Intflash of a PCD, if you are replacing an internal micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102069)
- What is stored on the micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102068)
- New firmware 1.08.16 for PCD1 E-Line Rio's (FAQ #102061)
- Is it possible to know the firmware version of the Top Print of the PCD1 E-Line RIOs? (FAQ #102059)
- What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102058)
- Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026)
- What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102010)
- PG5 2.1 and 2.2 with E-Line S-Bus communication library < 1.2.110, why the S-Bus communication on the master PCD stops either after a certain time? (FAQ #102009)
- PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or after the download of the program? (FAQ #102008)
- No Refresh from State of I/O's from E-Line Rio- Moduls after Fbox Update (FAQ #102001)
- What is the meaning of E-Line RIO – Leds & status specifications (FAQ #101998)
- What are the differences between E-Line firmwares FW 1.04.07 and 1.08.06? (FAQ #101990)