PP26-215 EN12a SBC System catalogue 2015/2016 - page 141

141
saia-pcd.com
Navigation
www
.
s-monitoring
.
com
seeback
MainMenu
Energymeter
Consumption
TODAY
Energymeter extended
Consumption
WEEK
Trend
EnergymeterDisplay
Consumption
MONTH
Consumption
YEAR
Functions
Setup
1
Cost
TODAY
Cost
WEEK
Cost
MONTH
Cost
YEAR
Advanced
Functions
need tobe
enabled
inSetup!
BasicFunction
Saia-BurgessControlsAG
Bahnhofstrasse18 |3280Murten,Switzerland
T+4126 6727272 |F+4126 6727499
|
PP26-582 EN04 07.2014
Subject to changes to technicaldetailsandfigures.
Consumption data collection
5
Switch cabinet
components
4
Consumer
data acquisition
3
Dedicated
room controllers
2
Operation
and monitoring
1
Automation
stations
SBC delivers a PG5 project, which also includes a web visualisation. The project is based on the COSinus functions and enables
saved data to be visualised on the PC immediately. As only the S-Monitoring COSinus function is accessed in the web project,
it does not need a PG5 program. It can therefore be easily integrated into existing projects. In addition, the most important
websites are available as macros in Web Editor 8.
S-Monitoring web project
 Recording of energy values
Plug & count
Automatic detection of connected energy
meters
Display of the energy meter status
Grouping of energy meters
Comparison between meter and periods
Connection of bidirectional meters
Connection PCD7.H104SE S0 impulse counter
(for S0 meters)
 Display and analysis of energy values
Current meter values such as consumption,
voltage, current, active and reactive power and
cosφ
Evaluation and presentation of the costs
Visualisation in bar charts and trend charts
Consumption and costs presentation
per day/week/month/year1)
Data storage in Excel-readable CSV files
 Remote access via network and Internet
Operation at the PC with standard browser
(IE, Chrome, Firefox)
Operation via smartphone and tablet
Access to log data and web project with FTP
Integrated USB port for update and maintenance
 User support
User administration with up to 2 user levels
?
!
. . .
Control interface in several languages
Technical data for SBC S-Monitoring
SBC S-Monitoring COSinus
function integrated in
PCD1.M0160E0 (e-Controller)
PCD3.Mxx60
PCD7.D457VT5E (e-Monitor)
PCD1.M2160
PCD7.DxxxxT5F (pWeb Panel MB)
Supported meters
– Saia PCD®S-Bus energy meters, PCD7.H104SE S0 pulse counters
– Incremental meter values (M-Bus, Modbus, etc. are referred to as "custom meters" and captured via FBoxes in the Fupla program)
– Meter groups
Maximum number of meters
128 Saia PCD
® S-Bus meters* / 256 custom meters* / 32 groups**in total max. 256
Data storage time
4 years max.
saved data
max. 4 meter values with 4 tariffs per meter are saved once a day (at midnight)
1)
Daily view only available if memory extension is plugged in
In the PG5 application for the e-Controller and e-Monitor
products supplied ready for use on delivery from the factory,
additional "Advanced" functions are programmed in PG5.
These cannot therefore be used without the program.
S-Monitoring is also supported by pWeb Panel PCD7.DxxxxT5F,
PCD1.M2160 and PCD3.Mxx60
Complete overview of the basic application
Basic functions of the S-Monitoring application
A...,131,132,133,134,135,136,137,138,139,140 142,143,144,145,146,147,148,149,150,151,...Z