• PCD1.A1000-A20

     

     

  • E-Line RIO 10DO

E-Line digital output module
Manual priority operating level for all outputs
Status LED for outputs
Supply 24 VDC
10 digital outputs 24 VDC (12...32VDC/0.5A)
1 interface RS-485 (S-Bus and Modbus)
Bridge connectors for power supply and communication to connect to next RIO module

  • PCD1.A2000-A20

     

     

  • E-Line RIO 6Rel

E-Line digital output module
Manual priority operating level for all outputs
Status LED for outputs
Supply 24 VDC
6 relais outputs (normally open) 230 VAC / 30 VDC, 16A (resistive load)
1 interface RS-485 (S-Bus and Modbus)
Bridge connectors for power supply and communication to connect to next RIO module

 

 

Documentation

System Catalogue : E-Line

Extract 26-215_A0160 System Catalogue : E-Line

Automation Stations - PCD1 E-Line

ENG18a .pdf 5.05 MB Download
FRA18a .pdf 5.06 MB Download
GER18a .pdf 5.07 MB Download
ITA18a .pdf 5.06 MB Download

Remote E-Line IOs L-Series

Flyer PP31-018 Remote E-Line IOs L-Series

ENG08 .pdf 0.95 MB Download
FRA08 .pdf 0.96 MB Download
GER08 .pdf 0.97 MB Download
ITA04 .pdf 0.95 MB Download

Remote E-Line IOs S-Series

Flyer PP31-055 Remote E-Line IOs S-Series

ENG03 .pdf 0.74 MB Download
FRA03 .pdf 0.75 MB Download
GER03 .pdf 0.75 MB Download
ITA03 .pdf 0.74 MB Download

PCD1.A1000-A20 E-Line S-Series RIO 10DO

Datasheet PP31-146 PCD1.A1000-A20 E-Line S-Series RIO 10DO

The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.

ENG11 .pdf 1.70 MB Download
FRA11 .pdf 1.73 MB Download
GER11 .pdf 1.72 MB Download
ITA11 .pdf 1.71 MB Download

PCD1.A2000-A20 E-Line S-Series RIO 6Rel

Datasheet PP31-147 PCD1.A2000-A20 E-Line S-Series RIO 6Rel

The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.

ENG13 .pdf 1.89 MB Download
FRA13 .pdf 1.92 MB Download
GER13 .pdf 1.92 MB Download
ITA13 .pdf 1.90 MB Download

Template for labels for the E-Line RIO coverset

Presentation E-Line RIO coverset Template for labels for the E-Line RIO coverset

.pptx 0.40 MB Download

Pictures - PCD1.A1000-A20

Info 800 × 800 pixel Pictures - PCD1.A1000-A20

    

S-Serie

front view .png 0.42 MB Download
front view - LEDs active .png 0.42 MB Download
isometrical view .png 0.34 MB Download
isometrical view - LEDs active .png 0.34 MB Download

Pictures - PCD1.A2000-A20

Info 800 × 800 pixel Pictures - PCD1.A2000-A20

       

S-Serie

front view .png 0.40 MB Download
front view - LEDs active .png 0.40 MB Download
isometrical view .png 0.34 MB Download
isometrical view - LEDs active .png 0.34 MB Download

Pictures - PCD1.K0206-005

Info 800 × 800 pixel Pictures - PCD1.K0206-005

S-Serie & L-Serie

frontal view .png 0.22 MB Download
.png 0.15 MB Download

Pictures - PCD1.K0206-025

Info 800 × 800 pixel Pictures - PCD1.K0206-025

S-Serie & L-Serie

front view .png 0.26 MB Download
isometrical view .png 0.16 MB Download

Pictures - bridge connector

Info 800 × 800 pixel Pictures - bridge connector

      

Bridge connector for S-Serie

front view .png 0.63 MB Download
isometrical view .png 0.57 MB Download

Web-templates for Web-Editor8

Web-8 Templates for E-Line RIO Modules

Software Web-8 Templates for E-Line RIO Modules

Web-Editor 8 templates for PG5 2.1 for the following modules:

  • PCD1.B1000
  • PCD1.B1010
  • PCD1.B1020
  • PCD1.G5000
  • PCD1.G5010
  • PCD1.G5020

To import the files in to the Web-Editor8, do open the Web-Editor8 and do click with the right mouse key to the "Librarires" window of the the Web-Edior8 and select the point "Import" and browse to the location where you have stored the zip files.
After the import the templates are available in the menu "E-Line, RIO"

1.0.17 .zip 0.14 MB Download

Minimal Firmware configuration

The minimum Firmware for the head station is 1.24.25

 

 

E-Line configuration App

The E-Line App does allow to configure the communication protocol on the RS485 of the E-Line RIO’s (S-Bus or Modbus) the baudrate and the parity and stop bit as the station number of the E-Line RIO device.

The E-Line App does run on PC’s with Windows 7 and Windows 10 operation systems.
USB connection to the PCD1 E-Line RIO’s is required.

E-Line RIO configuration App

Software PG5 2.3.195 E-Line RIO configuration App

The E-Line App does allow to configure the communication protocol on the RS485 of the E-Line RIO’s (S-Bus or Modbus) the baudrate and the parity and stop bit as the station number of the E-Line RIO device.

The E-Line App does run on PC’s with Windows 7, Windows 10 and Windows 11 (32/64 - Bit) operation systems.
USB connection to the PCD1 E-Line RIO’s is required.

PG5 2.3.195 .zip 24.44 MB Download

PCD1 E-Line firmware used in production

Firmware used in production PCD1.E-Line programmable modules and RIO I/O modules

Firmware Package 1.04.24/1.08.06/1.08.13 Firmware used in production PCD1.E-Line programmable modules and RIO I/O modules

This firmware is used in the PCD production and the PCD1 E-Line programmable modules and RIO I/O modules L-Series and S-Seires are shipped with this firmware.

The programmable I/O modules:

FW 1.04.24

PCD1.G1100-C15
PCD1.G360x-C15
PCD1.F2611-C15
PCD1.W5300-C15

The RIO modules L-Series:

FW 1.08.06

PCD1.B1000-A20
PCD1.B1010-A20
PCD1.B1020-A20
PCD1.G5000-A20
PCD1.G5010-A20
PCD1.G5020-A20

The RIO modules S-Series:

FW 1.08.13

PCD1.A1000-A20
PCD1.A2000-A20
PCD1.B5000-A20
PCD1.B5010-A20
PCD1.E1000-A20
PCD1.G2000-A20
PCD1.G2100-A20
PCD1.G2200-A20
PCD1.W5200-A20 

1.04.24/1.08.06/1.08.13 .zip 0.57 MB Download

Good to know

PG5 2.1.410 or later is to be used for working with the PCD1 E-Line

PCD1 / E-Line

  • How to copy csv-Files and Webeditorproject files which are stored on the Intflash of a PCD, if you are replacing an internal micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102069)
  • What is stored on the micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102068)
  • New firmware 1.08.16 for PCD1 E-Line Rio's (FAQ #102061)
  • Is it possible to know the firmware version of the Top Print of the PCD1 E-Line RIOs? (FAQ #102059)
  • What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102058)
  • Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026)
  • What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102010)
  • PG5 2.1 and 2.2 with E-Line S-Bus communication library < 1.2.110, why the S-Bus communication on the master PCD stops either after a certain time? (FAQ #102009)
  • PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or after the download of the program? (FAQ #102008)
  • No Refresh from State of I/O's from E-Line Rio- Moduls after Fbox Update (FAQ #102001)
  • What is the meaning of E-Line RIO – Leds & status specifications (FAQ #101998)
  • What are the differences between E-Line firmwares FW 1.04.07 and 1.08.06? (FAQ #101990)

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

Download