Produkt Index PCD7 Lxxx: RIOs und Room Controller LRxx-P5: PG5 programmierbarer Raumregler

  • PCD7.LRxx-P5

  • Mit PG5 frei programmierbarer Raumregler

Dokumentation

System Catalogue : PG5 programmable Room Controllers

Extract PP26-215_A0310 System Catalogue : PG5 programmable Room Controllers

System Catalgue: Book A Chapter 3.1

PG5 freely programmable S-Bus/Modbus room controllers for flexible and individual room solutions

ENG16 .pdf 1.26 MB Download
FRA16 .pdf 1.26 MB Download
GER16 .pdf 1.26 MB Download
ITA16 .pdf 1.26 MB Download

PCD7.LRxx-P5 Room Controller - PG5 programmable

Datasheet PP31-405 PCD7.LRxx-P5 Room Controller - PG5 programmable

ENG02 .pdf 1.45 MB Download
FRA02 .pdf 1.46 MB Download
GER02 .pdf 1.44 MB Download
ITA02 .pdf 1.46 MB Download

PCD7.LRxx-P5 Saia PG5® Programmable Room Controller

Technical Info 0643GE51_MU1B PCD7.LRxx-P5 Saia PG5® Programmable Room Controller

R0418C .pdf 1.58 MB Download
R0418C - sheets .pdf 1.65 MB Download

PCD7.LRxx-P5 Room controller - PG5 programmable

Manual 27-653 PCD7.LRxx-P5 Room controller - PG5 programmable

- Freely programmable using Saia PG5.

- Mains or 24 VAC supply voltage.

- Flexible use of relays and Triacs (24 VAC or 230 VAC).

- 24 VAC supply for field devices.

- Support of Honeywell Sylk™ wall modules.

- Smart engineering and commissioning tools reduce the total installation costs.

ENG07 .pdf 12.61 MB Download
FRA07 .pdf 12.55 MB Download
GER07 .pdf 12.58 MB Download
ITA07 .pdf 12.55 MB Download

Raumbedieneinheit

PCD7.D1000 - Wall Unit

Datasheet PP31-308 PCD7.D1000 - Wall Unit

Wall unit for room temperature measurement, set point offset control.

The design is in line with the PEHA Dialog Aluminium wall switch portfolio.

ENG04 .pdf 0.47 MB Download
FRA04 .pdf 0.48 MB Download
GER04 .pdf 0.48 MB Download
ITA04 .pdf 0.48 MB Download

PCD7.LR-TR40 and PCD7.LR-TR42 LCD and non-LCD Wall Modules

Datasheet PP31-409 PCD7.LR-TR40 and PCD7.LR-TR42 LCD and non-LCD Wall Modules

Part number Description Sensors Communication

- PCD7.LR-TR40 Wall Module, Temp only, Sylk Temperature Sylk

- PCD7.LR-TR40-H Wall Module, Temp and Humidity, Sylk Temp, Humidity Sylk

- PCD7.LR-TR40-CO2 Wall Module, Temp and CO2, Sylk Temp, CO2 Sylk

- PCD7.LR-TR40-H-CO2 Wall Module, Temp, Humdity, CO2, Sylk Temp, Hum, CO2 Sylk

- PCD7.LR-TR42 LCD Wall Module, Temp only, Sylk Temperature Sylk

- PCD7.LR-TR42-H LCD Wall Module, Temp and Humidity, Sylk Temp, Humidity Sylk

- PCD7.LR-TR42-CO2 LCD Wall Module, Temp and CO2, Sylk Temp, CO2 Sylk

- PCD7.LR-TR42-H-CO2 LCD Wall Module, Temp, Humidity, CO2, Sylk Temp, Hum, CO2 Sylk

ENG01 .pdf 0.18 MB Download
FRA01 .pdf 0.19 MB Download
GER01 .pdf 0.19 MB Download
ITA01 .pdf 0.19 MB Download
SPA01 .pdf 0.19 MB Download

PCD7.LR-TR40 and PCD7.LR-TR42 LCD and non-LCD Wall Modules

Technical Info PP31-408 PCD7.LR-TR40 and PCD7.LR-TR42 LCD and non-LCD Wall Modules

Part number Description Sensors Communication

- PCD7.LR-TR40 Wall Module, Temp only, Sylk Temperature Sylk

- PCD7.LR-TR40-H Wall Module, Temp and Humidity, Sylk Temp, Humidity Sylk

- PCD7.LR-TR40-CO2 Wall Module, Temp and CO2, Sylk Temp, CO2 Sylk

- PCD7.LR-TR40-H-CO2 Wall Module, Temp, Humdity, CO2, Sylk Temp, Hum, CO2 Sylk

- PCD7.LR-TR42 LCD Wall Module, Temp only, Sylk Temperature Sylk

- PCD7.LR-TR42-H LCD Wall Module, Temp and Humidity, Sylk Temp, Humidity Sylk

- PCD7.LR-TR42-CO2 LCD Wall Module, Temp and CO2, Sylk Temp, CO2 Sylk

- PCD7.LR-TR42-H-CO2 LCD Wall Module, Temp, Humidity, CO2, Sylk Temp, Hum, CO2 Sylk

ENG01 .pdf 0.80 MB Download
FRA01 .pdf 0.80 MB Download
GER01 .pdf 0.80 MB Download
ITA01 .pdf 0.80 MB Download
SPA01 .pdf 0.80 MB Download

Q.RCU-A-xxxx Analog room control unit, installation instructions

Technical Info 26-605 Q.RCU-A-xxxx Analog room control unit, installation instructions

ENG01 .pdf 0.71 MB Download

Extract Manual PCD7.L63x

Extract 26-237 Extract Manual PCD7.L63x

Extract from the document: 26-859 manual PCD7.L6xx

EN05 .pdf 0.54 MB Download

Room Vorlagen für den PG5 programmierbaren Raumregler PCD7.LRxx-P5

Die folgende Projektvorlage kann mit PG5 2.3 oder neuer, verwendet werden.
Die Installation der Projektvorlage erfolgt in PG5 mittels "Restore project..."

PG5 room template

Manual PG5 room template

The room template covers recently required HVAC room automation demands, like heating, cooling, FanCoil, presence detection. Beside this, the template is designed also to emulate a L60x room controller (partly), so a replacement of a L60x room controller by a freely programmable device can be done quite easy.

The room template is dedicated to being used on PCD7.LRxx-P5 devices, but can be used on any other programmable device. In this case, some features must be removed or disabled, e.g. the SYLK Bus wall module (only available on PCD7.LRxx-P5) or the L60x emulation.

The room template has been created with PG5 2.3.

GER02 .pdf 1.56 MB Download
ENG02 .pdf 1.52 MB Download
FRA02 .pdf 1.61 MB Download

PG5 room template, PG5 2.3 application program

Software PG5 room template, PG5 2.3 application program

.zip 4.27 MB Download

FBox for PCD7.LRxx-P5 programmable IRM

Software FBox for PCD7.LRxx-P5 programmable IRM

FBox library for:

  • PCD7.LRxx-P5
  • Distributed Alarming

 

 

FBox lib for PCD7.LRxx-P5 programmable IRM V 1.0.150 .saiazip 1.35 MB Download
FBox lib for Distributed Alarming V 2.9.220 .saiazip 4.68 MB Download

Firmware für PCD7.LRxx-P5 programmierbarer Raumregler

PCD7.LRxx-P5; firmware used in production

Firmware 1.10.07 PCD7.LRxx-P5; firmware used in production

This firmware is used in the PCD production and the PCD's are shipped with this firmware.
To update the FW use the 'Firmware donwloader' from the 'PG5 project manager' or from the 'S-Online tools'

 

 

1.10.07 .blk 0.26 MB Download

Good to know

Um die PCD7.LRxx-P5 programmierbaren Raumregler zu verwenden müssen die folgenden Versionen verwendet werden:

  • PG5: PG5.2.3.113 oder neuer
  • PCD FW: Firmware 1.10.06 oder neuer

 

Die Unterschiede zwischen Firmware Version 1.10.00 und 1.10.07 werden im FAQ 102024 aufgelistet

PCD7 / Rxx-P5

  • Warum kann der PCD7.LRxx-P5 IRM Raumregler als S-Bus Master, keine Daten (Eingänge und Ausgänge) über S-Bus aus S-Bus Slave Geräten auslesen/schreiben? (FAQ #102029)
  • Für den PCD7. LRxx-P5, was sind die Unterschiede zwischen den Firmwaren FW 1.10.00 und FW 1.10.07? (FAQ #102024)

Die von Ihnen angeforderte Software / Dokument wird von der Saia-Burgess Controls AG nicht mehr vermarktet und technisch unterstützt. Es handelt sich um eine ältere Software-Version, die lediglich auf bestimmten, mittlerweile nicht mehr im Handel erhältlichen Produkten betrieben werden kann.

Download