Het spijt ons. Uw verzoek kon niet worden verwerkt.

Product Category Remote I/O PCD3.T66x Smart Ethernet RIO

  • PCD3.T665 | PCD3.T666

  • Smart Ethernet RIOs

Documentation

System Catalogue : PCD3

Extract 26-215_A0120 System Catalogue : PCD3

Chapter:
Automation Stations - PCD3

ENG18c .pdf 4.66 MB Download
FRA18c .pdf 4.67 MB Download
GER18c .pdf 4.69 MB Download
ITA18c .pdf 4.67 MB Download

Smart-RIO PCD3.T665/T666

Manual 26-892 Smart-RIO PCD3.T665/T666

  

ENG06 .pdf 6.83 MB Download
FRA06 .pdf 6.88 MB Download
GER06 .pdf 6.83 MB Download
ITA06 .pdf 6.87 MB Download

PCD3 Hardware

Manual 26-789 PCD3 Hardware

ENG21 .pdf 16.34 MB Download
FRA21 .pdf 15.65 MB Download
GER21 .pdf 17.97 MB Download
ITA21 .pdf 15.28 MB Download

IO-Modules

Manual 27-600 IO-Modules

I/O modules for the series PCD1 | PCD2 and PCD3

ENG11 .pdf 20.93 MB Download
FRA11 .pdf 19.39 MB Download
GER11 .pdf 21.94 MB Download
ITA11 .pdf 21.09 MB Download

TCP/IP - Ethernet for the Saia PCD® Serie

Manual 26-776 TCP/IP - Ethernet for the Saia PCD® Serie

ENG13 .pdf 21.09 MB Download
FRA13 .pdf 20.91 MB Download
GER13 .pdf 10.50 MB Download
IT03 Archive .pdf 4.43 MB Download

TCP/IP-Enhancements

Manual 26-867 TCP/IP-Enhancements

ENG05 .pdf 3.55 MB Download
FRA05 .pdf 3.47 MB Download
GER05 .pdf 3.51 MB Download

Leaflet: PCD3.T66x

Readme 35-017 Leaflet: PCD3.T66x

Base Station Remote I/O Saia PCD3.T665 and PCD3.T666, both with Ethernet

ENG06 .pdf 0.10 MB Download

Firmware used in production

The actual COSinus FW 1.22.xx is available from the COSinus firmware page.

Software / Tools

For the power calculation of the I/O modules the Device Configurator from PG5 2.0. SP2 is to be used. PG5 2.0 Device Configurator does also feature a label creator for the I/Os on the RIO.

Good to know

FW 1.20.36 or newer is needed to feature the integration of L&S NI1000 temperature sensors on different W-Modules. This Firmware also supports the use of 16k Registers / Flags. Therefore you also need the PG5 2.1.100.100.

FW 1.16.52 or newer is needed to use the PCD3.F27x (except PCD3.F270) module on the PCD3.T766.
There is an example from the Smart Ethernet RIOs available in the Getting Started section.

PG5 2.0.200 does not correctly map the "ManagerNotPresent" diagnostic flag, see FAQ 101652.

The RIO firmware 1.16.42 does not update the diagnostic flags if started without manager, see FAQ 101653. Minimal firmware version for the Manager is 1.16.42 (PCD1.M2) and 1.16.45 (PCD2.M5 and PCD3), see FAQ 101640.

Minimal version of PG5 for configuring a PCD3.T665|T666 is PG5 2.0 SP2 (PG5 2.0.200).

When replacing a PCD3.T660 by a PCD3.T665 the user program needs to be adapted accordingly.

I/O modules:
The I/O modules are delivered per default with a spring clamp terminal block.
Screw terminal blocks have to be ordered separately.

Communication / Ether-S-I/O

  • Are SBC devices affected by the zero-day vulnerabilities ‘Ripple20’, related to the low-level TCP/IP software library developed by Treck, Inc.? (FAQ #102036)
  • It's possible that the same master PCD is able to handle PCD3.T665/T666 and PCD3.T660? (FAQ #101842)
  • Why can't I copy an Ethernet RIO within the Saia PG5® RIO Network Configurator? (FAQ #101678)
  • Why can't I detect that the RIO manager is missing during the start of the RIO? (FAQ #101653)
  • Why is the diagnostic flag "ManagerNotPresent" on the RIO not set? (FAQ #101652)

PG5 2.0 / Library Manager

  • Shall I use PG5 2.3, PG5 2.2, 2.1, 2.0 or PG5 1.4 for my next project? (FAQ #102018)

PCD3 / T665 | T666

  • For the PCD3.T665/T666/T668 it’s possible to define on the PG5 device configurator own FTP users, service key or the web-server password? (FAQ #102038)
  • Why is the diagnostic flag of the PCD3.T665 / T666 partially not automatically reset on the Ethernet Smart-RIO manager after Ethernet network interruption? (FAQ #101995)
  • Why appears the following S-RIO internal error message? (FAQ #101940)
  • Can I use DALI on the PCD3.T666? (FAQ #101902)
  • On PG5 2.1 the 'fatal error 2004' is shown after building a project where a smart RIO PCD3.T665/T666 is used. (FAQ #101871)
  • The data exchange to smart RIO does not work with certain FW version! (FAQ #101860)
  • It's possible that the same master PCD is able to handle PCD3.T665/T666 and PCD3.T660? (FAQ #101842)
  • What are the differences between firmware 1.16.69 and COSinus FW 1.22.61? (FAQ #101820)
  • SWeb Alarming is not supported on Smart-RIO PCD3.T665 / PCD3.T666 (FAQ #101803)
  • Why the exchange of ‘data transfer array’ between the PCD3.T66x smart RIO’s and the smart automation manager does no more work after installing the patch 1 of PG5 2.0.220? (FAQ #101785)
  • What is the signification of the history entry "ESIO CFG FAIL nn"? (FAQ #101778)
  • Can I "stop" the programm execution of a Smart Ethernet RIO (PCD3.T665 or PCD3.T666)? (FAQ #101768)
  • Diagnostic flag from SMART RIO is high for a short time after a program download (FAQ #101752)
  • Why can't I detect that the RIO manager is missing during the start of the RIO? (FAQ #101653)
  • Why is the diagnostic flag "ManagerNotPresent" on the RIO not set? (FAQ #101652)
  • Why does the data exchange to the RIO not work after the program has been restored? (FAQ #101640)
  • What are the differences between firmware 1.14.23 and 1.16.69? (FAQ #101624)
  • Which special modules can I plug on the PCD3.T666? (FAQ #101603)

The requested software / document is no longer marketed by Saia-Burgess Controls AG and without technical support. It is an older software version which can be operated only on certain now no longer commercially available products.

Download