Documentation download area (Building Automation)
Catalogue and market information
System Catalogue 2022/2023
Catalogue | 26-215 | System Catalogue 2022/2023 |
Field Devices Honeywell
Flyer
Sensors Product Overview
Flyer | PP31-033 | Sensors Product Overview |
PCD1.P1001-J30
Flyer | PP31-043 | PCD1.P1001-J30 |
E-Line-Room-Control
Flyer | PP31-026 | E-Line-Room-Control |
Remote E-Line IOs L-Series
Flyer | PP31-018 | Remote E-Line IOs L-Series |
Flyer SBC E-Line
Flyer | PP26-578 | Flyer SBC E-Line |
Datasheets
Saia PCD® Supervisor
Datasheet | 34-001 | Saia PCD® Supervisor |
Saia PCD® Supervisor,
is a building monitoring and management solution built upon the powerful Niagara platform.
It is capable of integrating Saia PCD® controllers, third party devices and internet protocols into a centralised software platform that is designed to manage buildings at an enterprise level.
ENG07 | 1.02 MB | Download | |||
FRA07 | 1.05 MB | Download | |||
GER07 | 1.05 MB | Download | |||
ITA07 | 1.04 MB | Download |
Saia PCD® Supervisor EM
Datasheet | PP34-002 | Saia PCD® Supervisor EM |
PCD1.M2220-C15: E-Line CPU with Ethernet, 512 kB
Datasheet | 31-100 | PCD1.M2220-C15: E-Line CPU with Ethernet, 512 kB |
Features
- 4 digital inputs
- 2 analogue inputs, individually configurable via software
- 1 Watchdog relay/changeover contact
- Electrical isolation between supply, bus and I/Os
- Pluggable terminal blocks protected by flaps
- Status LEDs on the front
- Ethernet switch, 2× RS-485, USB and NFC interface
- Large onboard memory for data (up to 128 MByte file system)
- Automation server for integration in web+IT systems
- Freely programmable with Saia PG5®
ENG06 | 1.22 MB | Download | |||
FRA06 | 1.22 MB | Download | |||
GER06 | 1.22 MB | Download | |||
ITA06 | 1.22 MB | Download | |||
SPA06 | Download |
PCD1.F2611-C15 E-Line DALI module and RS-485
Datasheet | PP31-112 | PCD1.F2611-C15 E-Line DALI module and RS-485 |
E-Line DALI module and auxillary RS-485.
The freely programmable module with a housing width of 35 mm (2 HP) can be controlled via RS-485 and enable the direct control of 64 DALI subscribers.
ENG04 | 1.33 MB | Download | |||
FRA04 | 1.33 MB | Download | |||
GER04 | 1.34 MB | Download | |||
ITA04 | 1.33 MB | Download |
PCD1.G1100-C15 E-Line Licht & Beschattungsmodul
Datasheet | 31-111 | PCD1.G1100-C15 E-Line Licht & Beschattungsmodul |
PCD1.G360x-C15 E-Line room control module
Datasheet | PP31-110 | PCD1.G360x-C15 E-Line room control module |
PCD1.W5300-C15 E-Line analogue module
Datasheet | PP31-113 | PCD1.W5300-C15 E-Line analogue module |
The module has a housing width of 35 mm (2 HP) that is compatible with electrical control cabinets, is controlled via RS-485 and enables the recording of analogue measurement signals and the control of actuators with analogue control variables.
ENG03 | 1.11 MB | Download | |||
FRA03 | 1.13 MB | Download | |||
GER03 | 0.97 MB | Download | |||
ITA03 | 1.11 MB | Download |
PCD1.A1000-A20 E-Line S-Series RIO 10DO
Datasheet | PP31-146 | PCD1.A1000-A20 E-Line S-Series RIO 10DO |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG11 | 1.70 MB | Download | |||
FRA11 | 1.73 MB | Download | |||
GER11 | 1.72 MB | Download | |||
ITA11 | 1.71 MB | Download |
PCD1.A2000-A20 E-Line S-Series RIO 6Rel
Datasheet | PP31-147 | PCD1.A2000-A20 E-Line S-Series RIO 6Rel |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG13 | 1.89 MB | Download | |||
FRA13 | 1.92 MB | Download | |||
GER13 | 1.92 MB | Download | |||
ITA13 | 1.90 MB | Download |
PCD1.B1000-A20 L-Series RIO 4DI, 10Rel
Datasheet | 31-143 | PCD1.B1000-A20 L-Series RIO 4DI, 10Rel |
The E-Line RIO modules are controlled via RS-485 and enable decentralised automation using industrial quality components. The data point mix is specifically designed for applications in the HVAC sector.
ENG10 | 1.95 MB | Download | |||
FRA10 | 1.98 MB | Download | |||
GER10 | 1.98 MB | Download | |||
ITA10 | 1.97 MB | Download |
PCD1.B1010-A20 L-Series RIO 24DI, 10Rel
Datasheet | 31-144 | PCD1.B1010-A20 L-Series RIO 24DI, 10Rel |
The E-Line RIO modules are controlled via RS-485 and enable decentralised automation using industrial quality components. The data point mix is specifically designed for applications in the HVAC sector.
ENG13 | 1.80 MB | Download | |||
FRA13 | 1.83 MB | Download | |||
GER13 | 1.83 MB | Download | |||
ITA13 | 1.81 MB | Download |
PCD1.B1020-A20 L-Series RIO 16DI, 4Rel
Datasheet | 31-145 | PCD1.B1020-A20 L-Series RIO 16DI, 4Rel |
The E-Line RIO modules are controlled via RS-485 and enable decentralised automation using industrial quality components. The data point mix is specifically designed for applications in the HVAC sector.
ENG09 | 1.76 MB | Download | |||
FRA09 | 1.78 MB | Download | |||
GER09 | 1.78 MB | Download | |||
ITA09 | 1.77 MB | Download |
PCD1.B1100-A20 E-Line S-Series RIO 4DI, 10Rel
Datasheet | PP31-155 | PCD1.B1100-A20 E-Line S-Series RIO 4DI, 10Rel |
E-Line S-Serie Digital input/output module
- manual override operating level for all outputs
- status LED for inputs and outputs
- supply 24 VDC
- 4 digital inputs; 24 VDC (source operation)
- 10 relay (6 normally open/ 4 changeover) 250 VAC / 30 VDC, 5 A (DC1)
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface
- Bridge connectors for power supply and communication to connect to next RIO module
ENG03 | 1.94 MB | Download | |||
FRA03 | 1.96 MB | Download | |||
GER03 | 1.96 MB | Download | |||
ITA03 | 1.95 MB | Download |
PCD1.B1120-A20 E-Line S-Series RIO 16DI, 4Rel
Datasheet | PP31-156 | PCD1.B1120-A20 E-Line S-Series RIO 16DI, 4Rel |
E-Line S-Serie Digital input/output module
- manual override operating level for all outputs
- status LED for inputs and outputs
- supply 24 VDC
- 16 digital inputs; 24 VDC (source operation)
- 4 relay changeover 250 VAC / 30 VDC, 5 A (DC1)
- 1 interface RS-485 (S-Bus and Modbus)
- 1 USB Service interface
- Bridge connectors for power supply and communication to connect to next RIO module
ENG03 | 2.78 MB | Download | |||
FRA03 | 2.00 MB | Download | |||
GER03 | 2.00 MB | Download | |||
ITA03 | 1.99 MB | Download |
PCD1.B5000-A20 E-Line S-Serie RIO 6DI 230V, 3Rel
Datasheet | PP31-148 | PCD1.B5000-A20 E-Line S-Serie RIO 6DI 230V, 3Rel |
The E-Line S-Serie RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG12 | 2.26 MB | Download | |||
FRA12 | 2.28 MB | Download | |||
GER12 | 2.28 MB | Download | |||
ITA12 | 2.26 MB | Download |
PCD1.B5010-A20 E-Line S-Serie RIO 6DI 24V, 3Rel
Datasheet | PP31-153 | PCD1.B5010-A20 E-Line S-Serie RIO 6DI 24V, 3Rel |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG04 | 1.93 MB | Download | |||
FRA04 | 1.95 MB | Download | |||
GER04 | 1.95 MB | Download | |||
ITA04 | 1.93 MB | Download |
PCD1.E1000-A10 E-Lines S-Serie RIO 12DI
Datasheet | PP31-149 | PCD1.E1000-A10 E-Lines S-Serie RIO 12DI |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG08 | 1.25 MB | Download | |||
FRA08 | 1.28 MB | Download | |||
GER08 | 1.27 MB | Download | |||
ITA08 | 1.26 MB | Download |
PCD1.G2000-A20 E-Line S-Series RIO 6UI, 2AO, 2TR
Datasheet | 31-150 | PCD1.G2000-A20 E-Line S-Series RIO 6UI, 2AO, 2TR |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG13 | 1.77 MB | Download | |||
FRA13 | 1.80 MB | Download | |||
GER13 | 1.78 MB | Download | |||
ITA13 | 1.78 MB | Download |
PCD1.G5000-A20 L-Series RIO 16DI, 8Rel, 8AI, 4AO
Datasheet | 31-140 | PCD1.G5000-A20 L-Series RIO 16DI, 8Rel, 8AI, 4AO |
The E-Line RIO modules are controlled via RS-485 and enable decentralised automation using industrial quality components. The data point mix is specifically designed for applications in the HVAC sector.
ENG13 | 2.85 MB | Download | |||
FRA13 | 2.87 MB | Download | |||
GER13 | 2.88 MB | Download | |||
ITA13 | 2.86 MB | Download |
PCD1.G5010-A20 L-Series RIO 12DI, 4Rel, 12AI, 8AO
Datasheet | 31-141 | PCD1.G5010-A20 L-Series RIO 12DI, 4Rel, 12AI, 8AO |
The E-Line RIO modules are controlled via RS-485 and enable decentralised automation using industrial quality components. The data point mix is specifically designed for applications in the HVAC sector.
ENG11 | 2.03 MB | Download | |||
FRA11 | 2.06 MB | Download | |||
GER11 | 2.06 MB | Download | |||
ITA11 | 2.04 MB | Download |
PCD1.G5020-A20 L-Series RIO 8DI, 4Rel, 16AI, 4AO
Datasheet | 31-142 | PCD1.G5020-A20 L-Series RIO 8DI, 4Rel, 16AI, 4AO |
The E-Line RIO modules are controlled via RS-485 and enable decentralised automation using industrial quality components. The data point mix is specifically designed for applications in the HVAC sector.
ENG12 | 1.87 MB | Download | |||
FRA12 | 1.88 MB | Download | |||
GER12 | 1.90 MB | Download | |||
ITA12 | 1.87 MB | Download |
PCD1.G2100-A10 E-Line S-Sries RIO 8UI
Datasheet | PP31-154 | PCD1.G2100-A10 E-Line S-Sries RIO 8UI |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG03 | 1.87 MB | Download | |||
FRA03 | 1.90 MB | Download | |||
GER03 | 1.89 MB | Download | |||
ITA03 | 1.88 MB | Download |
PCD1.G2200-A20 E-Line S-Series RIO 8UI, 4AO
Datasheet | PP31-151 | PCD1.G2200-A20 E-Line S-Series RIO 8UI, 4AO |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG11 | 1.58 MB | Download | |||
FRA11 | 1.61 MB | Download | |||
GER11 | 1.60 MB | Download | |||
ITA11 | 1.59 MB | Download |
PCD1.W5200-A20 E-Line S-Series RIO 8AO
Datasheet | PP31-152 | PCD1.W5200-A20 E-Line S-Series RIO 8AO |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG07 | 1.45 MB | Download | |||
FRA07 | 1.48 MB | Download | |||
GER07 | 1.47 MB | Download | |||
ITA07 | 1.46 MB | Download |
PCD7.D543RF - 4.3" HTML5 Web Panel, resistive touch
Datasheet | 34-013 | PCD7.D543RF - 4.3" HTML5 Web Panel, resistive touch |
PCD7.D570CF - 7" HTML5 Web Panel, capacitive touch
Datasheet | 34-014 | PCD7.D570CF - 7" HTML5 Web Panel, capacitive touch |
PCD7.D570RF - 7" HTML5 Web Panel, resistive touch
Datasheet | 34-015 | PCD7.D570RF - 7" HTML5 Web Panel, resistive touch |
PCD7.D521CF - 21.5" HTML5 Web Panel, cap. touch
Datasheet | 34-019 | PCD7.D521CF - 21.5" HTML5 Web Panel, cap. touch |
PCD7.D515CF - 15.6" HTML5 Web Panel, cap. touch
Datasheet | 34-018 | PCD7.D515CF - 15.6" HTML5 Web Panel, cap. touch |
PCD7.D510CF - 10.1" HTML5 Web Panel, cap. touch
Datasheet | 34-016 | PCD7.D510CF - 10.1" HTML5 Web Panel, cap. touch |
Manuals
PCD2.M4160, PCD2.M4560
Manual | 27-648 | PCD2.M4160, PCD2.M4560 |
PCD1.M2220-C15
Manual | 27-640 | PCD1.M2220-C15 |
Manual : PCD2.M5xxx
Manual | 26-856 | Manual : PCD2.M5xxx |
PCD1.M2xxx
Manual | 26-875 | PCD1.M2xxx |
PCD1.M2110R1 (Room)
Manual | 27-619 | PCD1.M2110R1 (Room) |
PCD1.M0160E0
Manual | 27-622 | PCD1.M0160E0 |
PCD7.LRxx-P5 Room controller - PG5 programmable
Manual | 27-653 | PCD7.LRxx-P5 Room controller - PG5 programmable |
- Freely programmable using Saia PG5.
- Mains or 24 VAC supply voltage.
- Flexible use of relays and Triacs (24 VAC or 230 VAC).
- 24 VAC supply for field devices.
- Support of Honeywell Sylk™ wall modules.
- Smart engineering and commissioning tools reduce the total installation costs.
ENG08 | 12.80 MB | Download | |||
FRA08 | 12.76 MB | Download | |||
GER08 | 12.78 MB | Download | |||
ITA08 | 12.74 MB | Download |
PCD7.LRxx BACnet Room Controller
Manual | 27-663 | PCD7.LRxx BACnet Room Controller |
BACnet Communication with the Saia PCD3 Automation Station