SBC Web HMI
Web-Panel with Micro-Browser, with Saia PCD® COSinus operating system
-
-
The SBC Micro-Browser panels (MB Panels) are based on the Saia PCD® COSinus operating system. The web pages displayed on these panels are created in the S-Web Editor which is part of the Saia PG5® Controls Suite.
-
-
WQVGA (480x272), TFT
-
-
WVGA (800x480), TFT
-
-
QVGA (320x240), STN
VGA (640x480), TFT
-
-
WVGA (800x480), TFT
-
-
VGA (640x480), TFT
-
-
SVGA (800x600), TFT
pWeb-Panel with Micro-Browser, with integrated programmable logic controller based on Saia PCD® COSinus operating system
-
-
On the pWeb Panels, in addition to the functions of the standard MB panel, a programmable logic controller is integrated.
Based on the COSinus operating system of the Saia PCD®, specific, complex control logic and local data processing logic can be implemented in one device. The priority here are the operating and visualisation functions that enable small control systems to be implemented. The control functions have a lower priority.
-
-
WQVGA (480x272), TFT
-
-
VGA (640x480), TFT
-
-
SVGA (800x600), TFT
-
-
VGA (640x480), TFT
Cyber secure touch Web-Panel with Linux operating system
-
-
The cyber secure touch Web-Panel with Linux operating system are delivered with an HTML5 Chromium Browser to access PCD Web-Server or any other HTML5 web-server. The HTML5 web pages displayed on these panels could be created with the S-Web Editor8 which is part of the PG5 Controls Suite and the QronoX ECS or with the Saia PCD Supervisor.
-
-
PCD7.D543RF
Resistive touchscreen -
4.3” TFT 15:9 - 64K, 480 × 272,
Linux 3.12, ARM Cortex-A8 - 1 GHz
-
-
PCD7.D570RF
Resistive touchscreenPCD7.D570CF
Capacitive touchscreen -
PCD7.D570RF: 7” TFT 15:9 - 64K, 800 × 480, WVGA,
Linux RT, ARM Cortex-A9 dual core - 800 MHzPCD7.D570CF: 7” TFT 15:9 - 16M, 800 × 480, WVGA,
Linux RT, ARM Cortex-A9 dual core - 800 MHz
-
-
PCD7.D510CF
Capacitive touchscreen -
10.1” TFT 16:10 - 16M, 1280 × 800, WXGA,
Linux RT, ARM Cortex-A9 dual core - 800 MHz
-
-
PCD7.D515CF
Capacitive touchscreen -
15.6” TFT - 16M, 1366 × 768, HD,
Linux RT, ARM Cortex-A9 quad core - 800 MHz
-
-
PCD7.D521CF
Capacitive touchscreen -
21.5” TFT - 16M, 1920 × 1080, full HD,
Linux RT, ARM Cortex-A9 quad core - 800 MHz
Web-Panel with Windows® operating system
-
-
The Web-Panel with Windows® operating system are delivered with an image including the SBC.Net WebConnect, a MicroBrowser (CE versions only) and additional useful tools. The web pages displayed on these panels are created in the S-Web Editor which is part of the PG5 Controls Suite.
-
-
WXGA 1280 x 800, TFT, Win CE, Atom
WXGA 1280 x 800, TFT, Win 7, Atom
-
-
WXGA 1280 x 800, TFT, Win CE, Atom
WXGA 1280 x 800, TFT, Win 7, Atom
WXGA 1280 x 800, TFT, Win 7, Celeron
-
-
WUXGA 1920 x 1080, TFT, Win 7, I7 quadcore
-
-
-
SVGA 800x600, TFT, Win CE, Geode LX
SVGA 800x600, TFT, Win CE, Atom
SVGA 800x600, TFT, Win eXP, Geode LX
SVGA 800x600, TFT, Win eXP, Atom
-
-
SVGA 800x600, TFT, Win CE, Geode LX
SVGA 800x600, TFT, Win XP, Geode LX
-
-
-
XGA 1024x768, TFT, Win CE, Geode LX
XGA 1024x768, TFT, Win CE, Atom
XGA 1024x768, TFT, Win XP, Geode LX
XGA 1024x768, TFT, Win XP, Atom
PCD7 / Dxxx Terminals
- Micro Browser Monochrome Display contrast changes (FAQ #100718)
- On Microbrowser panels with harware version <$C it is not possible to store teq- and gif-files on the panel. (FAQ #100576)
- PCD7.D7__ Ethernet Driver: error in commande function! (FAQ #100337)
- Fkeys don't work on PCD7.D16_ with HMI editor! (FAQ #100175)
S-Web Technology
- On HTML5 Web-Projects, created with Web-Editor8, why it is not possible to transfer the user and password after a url jump as it was possible on Java/MB? (FAQ #102035)
- HDLog in WE8: slow navigation (FAQ #101965)
- What means the error "Out of memory heap 3" (FAQ #101962)
- Why I get Message Window"Do you want to run this application?" by starting a Webproject? (FAQ #101952)
- Why IMaster Java Applet no longer run with Chrome? (FAQ #101951)
- After a „Reload“, the displayed HDLog Trend is not focused on the right, most actual, time (FAQ #101945)
- Web-Editor8, why the content of the Container variable is not displayed on the web-browser or the MB-display? (FAQ #101925)
- Why after a update of the Microbrowser Android app to the version 2.0.0_4 the error message 'file not found' is shown? (FAQ #101918)
- Why the error message ‘no such component found’ is shown on the web page? (FAQ #101917)
- After the update of Java to Java version 7, (update 6 or 7) a Java warning message is shown on my PC browser when accessing a web page stored on the PCD. (FAQ #101793)
- How to change the Favicon of a Web Project (FAQ #101782)
- WebEditor project with HDLog File to flash-memory: macro tries to load a wrong CSV-File (FAQ #101737)
- Why does the Micro Browser stop working with Error "File not found xxxx.teq"? (FAQ #101724)
- File written to the file system by the PCD can’t be accessed with HTTP protocol (FAQ #101686)
- What means the Error-6./alarm.exe?-6&sta failed? (FAQ #101674)
- Why are the Webserver password levels not working with firmware 1.14.xx or later? (FAQ #101613)
- How to disable borders and scrollbars when running the Microsoft Internet Explorer in Kiosk mode? (FAQ #101588)
- Are there known problems when accessing the PCD FTP server with FileZilla? (FAQ #101586)
- Why doesn't the Web Builder from PG5 2.0 find the license? (FAQ #101585)
- What do parameters 'speed' and 'priority' mean which get displayed on the status page of the PCD? (FAQ #101513)
- How long can I record data with the "HDLog to File FBox" (in csv format) using a 1 GB SD Card? (FAQ #101437)
- How many web-clients can be connected at the same time to the S-Web Server over Ether-S-Bus? (FAQ #101431)
- Problem with the FBox HD Log to File if the dynamic space of registers is defined as <1000 or >=10 000 (FAQ #101429)
- Why is the same entry created several times by the "HDLog to File" FBox library? (FAQ #101421)
- Which GIF-file formats are supported by the SBC S-Web technologies and how can I generate such GIFs? (FAQ #101409)
- Why is it not possible to compile the project if I add a curve in the HDLog to file macro? (FAQ #101375)
- Practical settings for the alarming macro in use with DDC Suite (FAQ #101342)
- How many HDLog trend variables can I log into one single CSV-file? (FAQ #101341)
- S-Web Editor recommendations for VGA MicroBrowser Panel projects (FAQ #101340)
- Why does the S-Web Editor warn about deletion of unused HTML tags in csv-file? (FAQ #101338)
- How can I prevent the Java Applet to be re-loaded when displaying my WebEditor created web pages? (FAQ #101288)
- Why do I get an error message "Internal symbols not defined" when building a PG5 project with HDLog file FBoxes? (FAQ #101263)
- Why is it not possible to compile a PG5 project containing a Web-Builder file on a PC with Chinese Windows? (FAQ #101250)
- Why is the webpage not displayed? Class not found exception (FAQ #101230)
- It’s possible to protect my web pages stored on the PCD, so that they can’t be copied? (FAQ #101229)
- How to load a web application from a PCD/PCS (without Ethernet port) to a remote PC with the use of a CE web-panel? (FAQ #101215)
- Why is the webpage not displayed? Class not found exception. Strange characters are displayed on top of the webpage. (FAQ #101200)
- What is the "WebServer2" on Saia PCD® COSinus systems? (FAQ #101191)
- Has the Web Server Time Allocation any influence? (FAQ #101179)
- How to hide the address bar on the IE7 or to put IE7 in to full screen mode? (FAQ #101148)
- Why the webpage is not displayed on the web-browser of the PC? Error message "Class not found" is displayed (but working fine on MB-webpanel) (FAQ #101142)
- Why my Web-Application is no more reacting after clicking on "Save Logs to file" button? (FAQ #101035)
- Why do the values on an eXP Web Panel freeze? (FAQ #100975)
- Why is the message: "Failed to get data on alarm.exe" displayed on the alarming page? (FAQ #100963)
- Why are the alarm texts not displayed? (FAQ #100934)
- Is it possible to store the web pages on a Web Panel? (FAQ #100931)
- Can I store files locally on a MB Panel (in order to increase communication performance)? (FAQ #100924)
- Does the Web-Editor allow to access array variables of PG5 symbolic names? (FAQ #100915)
- Is it possible to use symbolic names of PG5 resources on the Web-Editor if container offset is used? (FAQ #100914)
- How to use registers with addresses > 9999 on a web project? (FAQ #100913)
- Is it possible to know on the PCD if the Web-Application on a Web-Panel is running? (FAQ #100909)
- Why is the web-Server on the PCD is accessible over two different socket ports? (FAQ #100900)
- How to set the index of the Alarmlist FBox? (FAQ #100876)
- How to uninstall the Webserver password page? (FAQ #100873)
- Negative values with decimal point are not displayed correctly on the CE panel (FAQ #100842)
- S-Web Editor 5.13.00 dependencies (FAQ #100810)
- Why are the Webpages not always displayed? How to adjust the timeout of the WebServer? (FAQ #100808)
- Is it possible to run another application (Internet Explorer) from the Microbrowser on a CE panel? (FAQ #100768)
- Installed F-Boxes are not available (FAQ #100723)
- Applet malfunction after installing Sun Java Platform Edition 6 (Version 1.6) (FAQ #100708)
- Internet Explorer 7 does not support FTP connection (FAQ #100703)
- Alarming: When OnLine in fupla, FBox 10 Alarm displays xxxx instead of the values! (FAQ #100694)
- The PCD goes in HALT with a BUS ERROR if many accesses to the WebServer are executed (FAQ #100658)
- Why is the Internet Browser frozen after a few hours (FAQ #100648)
- Why is the message "syntax error" / "syntax error in tag" displayed instead of a value (FAQ #100632)
- Why are negativ values not displayed correctly? (FAQ #100630)
- URL Jump doesn't work with Microbrowser CE Terminal (FAQ #100617)
- What file names are allowed in the Web-Editor (FAQ #100552)
- Why is the message: "cannot create page content yet" appears from time to time (FAQ #100527)
- If I want to display Web pages on a PCD Web Panel CE, what is the difference between the use of Internet Explorer and the Micro Browser? (FAQ #100506)
- How to use the display of the MicroBrowser on the PCD Web Panel CE in full screen mode? (FAQ #100505)
- How to store a web page content which was uploaded from the PCD in to a Excel sheet? (FAQ #100476)
- Why does the error message "Can't generate ...web.itq length is 0" appers when generating a file with the Webbuilder? (FAQ #100429)
- PCD2.M170 or PCS1: WEB Server works only if a WEB project is downloaded in the PCD! (FAQ #100380)
- Why does the web page show "No component selected" instead of the media value? (FAQ #100379)
- What tools/technology should be used to create pages for the SBC-S-Web concept? (FAQ #100020)