Service Pack 2 (SP 2) for PG5 2.3 (PG5 2.3.175)
- This version include a complete installation package of PG5 2.3.175
- This version is installed in parallel with the precedent version of Saia PG5® 2.2.2xx or Saia PG5® 2.2.1xx
- Projects done with the version PG5 2.2.1xx/2.2.2xx/2.3.1xx will be fully compatible with this new version.
- Existing projects from PG5 2.2.1xx/2.2.2xx needs to be imported in to PG5 2.3.1xx
The default location for projects in PG5 2.3.1xx is:
c:\Users\<user name>\SBC\PG5 V2.3.1xx\Projects\
Default location for PG5 2.2.1xx/2.2.2xx projects was:
c:\Users\Public\SBC\PG5 V2.2.1xx\Projects\ or c:\Users\Public\SBC\PG5 V2.2.2xx\Projects\ - Dedicated F-Box libraries used in PG5 2.2.1xx/PG5 2.2.2xx needs to be installed again in PG5 2.3.1xx
- Installation:
Before installing PG5 2.3.175 it's necessary to uninstall manually older versions of PG5 2.3 (PG5 2.3.113/PG5 2.3.119/PG5 2.3.165)
For the installation, just start the setup. - It is also possible to install this version on computers which do not have the PG5 2.3.113/2.3.119/PG5 2.3.165 installed
- The user.key file used in PG5 2.2.1xx/2.2.2xx can't be used on PG5 2.3.1xx
- The user registration – ‘REGISTRATION.KEY’ from version 2.2 or previous versions is still valid and can be used for the user registration of this version
Fupla
- Type changes in .sy5 file are not applied in Fupla connectors
- Turn off FBox IDs in print preview
- Replacing a FBox in Fupla Editor with same group name does not work
- Imported Favorite FBox list is lost after Fupla restart
- Multiline descriptions are lost
- S_Ajust Tag in FUPLA FBoxes is also set if the parameter is a Timer
- Floating point with negative exponent is not accepted when decimal separator is comma.
- R Float symbol in Fupla is seen as R (integer) in Symbol Editor "All Publics" tab.
- Create FBox from Fupla page fails
SPM
- ProProject backups with S-Net files
- Incomplete import of PG5 1.4 projects
- Added files into the documentation file folder disappear when a device is restored
- Online debug information missing
- PG5, Project online command does not work correctly
- S_Adjust Tagginf for Backup/Restore not working in PG5 2.3.165.
BACnet
- PG5, BACnet Configurator, Upload/merge not possible and generate disassemble failed error message.
- Online error message in DDC Suite / BACnet project
·
Graftec
- SEdit Stays in processes and not closed after Going Online With Graftec/IL
- Not possible to compile Graftec file developed in PG5 2.2 Device Configurator
Device Conifgurator
- Not possible to put the PCD7.D443WT5R in RUN after a download of Device Configurator
- Configuration not consistent PCD7.LRL4-P5
Symbol Editor
- Symbols with accentuated characters no longer working
- PG5 AccessDatabaseEngine_2007.exe is not installed during setup
- Indexed symbols are not refreshed on parent symbol update
- Not possible to delete unused symbols from PG5 symbol editor P
- PG5 V2.3 is not able to read *.rxp file from VisiPlus.
Assembler
- Incorrect address resolution by array if the syntax "ArrayName[ElementN°]" is used.
- Build error from version PG5 V2.0
- Symbol _ArraySize_.myArray no more available
Easy Update
- Restoring *.SPRG clear all media (easyupdate & HTTP download)
- Easy Update does not download Users also when chosen in wizard, if there are some users already in the PCL they are not overwritten or deleated.
- Now in the source dialog, the checkbox "Device Program" is checked and disabled
Installer
- The installer of PG5 V2.3.175 do install .Net 4.6.2
- Web Editor 8 cannot be opened:The error ‘libgtk-win32-2.0-0.dll module cannot be found.
S-Web Editor 8.3.8.1185
- Copy and Paste issues from Objects between different pages or projects
- Web-Editor Bar Graph is not working in HMTL5
- Historic Data Logging in DBs (RAM logging) can't be displayed in HTML5 using WE8 Makro
- Web-Editor, Tacho scaling are always visible in HTML5
- Web-Editor in HTML5, not possible to write special char like éèüöä to PCD texts
- Float2DEC.2 and DEC.1 ... does not work on HTML5
- Offset of the decimal point on integer numbers on HTML 5.
- BACnet Web scheduler/calendar templates do not work for HTML5
- When in buttons Text alignment set to "Top" or "Bottom" the Text are shifted upwards or downwards.
- Required format for read and write different values not written or updated on view
- Configured "Display Time" not used in HTML5 TrendLog Macro
- S-Monitoring FW variable are not functional because of : character is cut from PCD medias
- Using a Condition in a Condition does not work in HTML5
- Settings rights to a layer they are ignored in HTML5
- HTML5 Date/Time format is not captured to min/max values
- Small polygon position shifts in HTML5
- Empty CSV tags are not handled identically on HTML5 and TEQ runtime
- Webserver not generated / Build error in TEQ.
- PCD Variables are 2 times added in the tcr file, the file grow by 2
- WE8 crashes when you create a new target (build menu)
- Condition Sequence cannot be changed Webeditor
- In case of resolving groups below a template instace a wrong typ id is generated
---------------------------------------------------------------------------------------------------------------------------
Service Pack 1 (SP 1) for PG5 2.3 (PG5 2.3.165)
- This version include a complete installation package of PG5 2.3.165
- This version is installed in parallel with the precedent version of Saia PG5® 2.2.2xx or Saia PG5® 2.2.1xx
- Projects done with the version PG5 2.2.1xx/2.2.2xx/2.3.1xx will be fully compatible with this new version.
- Existing projects from PG5 2.2.1xx/2.2.2xx needs to be imported in to PG5 2.3.1xx
The default location for projects in PG5 2.3.1xx is:
c:\Users\<user name>\SBC\PG5 V2.3.1xx\Projects\
Default location for PG5 2.2.1xx/2.2.2xx projects was:
c:\Users\Public\SBC\PG5 V2.2.1xx\Projects\ or c:\Users\Public\SBC\PG5 V2.2.2xx\Projects\ - Dedicated F-Box libraries used in PG5 2.2.1xx/PG5 2.2.2xx needs to be installed again in PG5 2.3.1xx
- Installation:
Before installing PG5 2.3.165 it's necessary to uninstall manually older versions of PG5 2.3 (PG5 2.3.113/PG5 2.3.119)
For the installation, just start the setup. - It is also possible to install this version on computers which do not have the PG5 2.3.113/2.3.119 installed
- The user.key file used in PG5 2.2.1xx/2.2.2xx can't be used on PG5 2.3.1xx
- The user registration – ‘REGISTRATION.KEY’ from version 2.2 or previous versions is still valid and can be used for the user registration of this version
Improvements:
Graftec:
On PG5 2.3.165, the Graftec Editor supports now the complete range of functions and it's possible to use Fupla pages on Steps/Transitions.
The Symbol Editor has been removed from the Graftec editor. The Fupla or IL editor now has
exclusive access to the symbols.
Graftec editor is for editing the Graftec state machine, not the program itself, so it does not need the program's symbols. To edit symbols, open a Step or Transition in Fupla or IL.
When symbols are modified, changes are only made to the symbols in other Steps and Transitions when the editor's files are saved.
Saving one ST/TR file will now save ALL the modified ST/TR files which are open for that Graftec module.
Project Generator:
The Project Generator Wizard is now available.
Low performance on iOS devices:
Displaying HTML5 web-pages on iOS devices causes performance issues.
It took a long time to load a new page if you click on a button that has a view jump.
Corrections are implemented and available in the PG5 2.3 Service Pack.
Correction of version 2.3.165
- The following corrections are included in the version 2.3.165
Device Configurator
- Wrong configuration option chosable in Device Configurator
FW Downloader
- Error message is wrong when downloading not supported FW on a PCD3M5340 with version HW G
BACnet
- If the BACnet Compiler took more than 2 minutes, Project Manager terminated the build process due to the long reaction time.
Fupla
- Faster opening of Fupla files
- Delete unused symbols is no more working in Fupla
- Decimal constants inserted in Fupla connectors are not correctly displayed in Online Probes
- If a imported DB contains undefined elements, then the whole DB content was shifted
- Array address not renamed during Fupla template import
- PG5 symbol editor, exporting a selection of symbols in TreeView generates different groups in the exported file
- Symbol Editor. Long texts create error
- Hexadecimal constants are not supported in connectors
- Symbol self-reference prevents to open Fupla
- Find and replace does not work when “Look in” setting is “Search result”
- Typing "." in the block name (COB/PB/FB) from the property window doesn't work
- Symbol arrays having init values are wrongly exported into Fupla templates
- Not possible to write "R y" in a connector if a Ressource with address R yx already exists
- When Fupla is online, adjust parameters based on text arrays are wrongly displayed
- Incomplete handling of template indexed values
- Lines per page option gives a maximal value of 999 but if value is set above 200 there is a build error
- Scaling of toolbar is not good on 4k screen
- Excel format now handles large numbers of symbols correctly.
- Missing description in Adjust window for some FBoxes' Adjust Parameters
- Find and Replace Symbols did not copy the symbol's comment
- Corrected handling of inverter on page output connector
Graftec:
- Crash can happen when opening Graftec files containing symbol duplicates
- Graftec content is lost after upgrade project from PG5 2.2 to PG5 2.3
- Fupla ST/TR symbol editor shows duplicate external symbols
S-Web Editor 8.3.8.1104:
- Static CSV is not added to the HTML 5 base-csv-entries
- Wrong PPOs in template S-Monitoring - Navigation - all templates are implicated
- In Hybrid mode, the translation was not done for csv values on embedded views
- Embedded view not working on foreground
- Play mode in Hybrid does not work in Firefox
- Empty Page is displayed in Runtime for HTML5 platform
- Container MB_InactivityCounter is not set back to 0 in case of pressing buttons
- Export template in a zip file crash the Webeditor
- Web Edior hdf file reload issue
- Disable print-to-file due of crash
- WebEditor 8 + HTML5 property hide if not accessible, handling of user groupes behaves differently in TEQ and HTML5 different
- HTML5 property hidden if not accessible, handling of user groups in TEQ and HTML5 different
- The Rename feature caused problems with links to PCD variables
- Dropdown button image was disabled but still visible
- Variables with a container offset (Haus@CO_Haus@.Floor@...) were not displayed on HTML5
view, even if the variable exists in PG5 - The font of dropdown box was wrong in the Safari browser
- Online Alarm macro doesn't show the texts in HTML5
- Improved performance for HTML5 web pages on iOS devices.
---------------------------------------------------------------------------------------------------------------------------