Documentation download area (Counter | Energy Meter)
System Informations (SI's)
Technical Informations (TI's)
PCD7.H104S S0 to S-Bus module
Technical Info | PP26-457 | PCD7.H104S S0 to S-Bus module |
Single-phase energy meter ALD1 with S0-interface
Datasheet | PP26-502 | Single-phase energy meter ALD1 with S0-interface |
Main features
- Single-phase energy meter, 230 VAC 50 Hz
- Direct measurement up to 32 A
- Display of active power, voltage and current
- 7-digit LC-Display with backlight
- Lead seal possible with cap as accessory
- Precision class B according to EN50470-3
- Precision class 1 according to IEC62053-21
- S0 output
ENG07 | 0.80 MB | Download | |||
FRA07 | 0.80 MB | Download | |||
GER07 | 0.79 MB | Download | |||
ITA06 | 0.80 MB | Download |
3-phase energy meter ALE3 with S0-interface
Datasheet | PP26-491 | 3-phase energy meter ALE3 with S0-interface |
3-phase energy meter AWD3 with S0-interface
Datasheet | PP26-496 | 3-phase energy meter AWD3 with S0-interface |
ALD1D5FS00A3A00 - 1-ph. e-meter direct, S-Bus
Datasheet | PP26-523 | ALD1D5FS00A3A00 - 1-ph. e-meter direct, S-Bus |
Order Number
Standard Version: ALD1D5FS00A2A00
MID Version: ALD1D5FS00A3A00
Sealing caps: 4 104 7420 0
Main features
- Single-phase energy meter, 230 VAC 50 Hz
- Direct measurement up to 32 A
- Display of active power, voltage and current
- S-Bus Interface to query the data
- Reactive power and cos PHI available through interface
- Up to 254 meter can be connected to the S-Bus Interface
- 7-digit display
- Lead seal possible with cap as accessory
- Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
ENG07 | 1.06 MB | Download | |||
FRA07 | 1.05 MB | Download | |||
GER07 | 1.05 MB | Download | |||
ITA07 | 1.06 MB | Download |
3-phase energy meter ALE3 with SBC S-Bus
Datasheet | PP26-509 | 3-phase energy meter ALE3 with SBC S-Bus |
3-phase energy meter AWD3 with SBC S-Bus
Datasheet | PP26-512 | 3-phase energy meter AWD3 with SBC S-Bus |
ALD1D5FM00A3A00 - 1-ph. e-meter direct, M-Bus
Datasheet | PP26-530 | ALD1D5FM00A3A00 - 1-ph. e-meter direct, M-Bus |
Main features
- Single-phase energy meter, 230 VAC 50 Hz
- Direct measurement up to 32 A
- Display of active power, voltage and current
- M-Bus Interface to query the data
- Reactive power available through interface
- Up to 250 meter can be connected to the M-Bus Interface
- 7-digit display
- Lead seal possible with cap as accessory
- Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
ENG08 | 1.25 MB | Download | |||
FRA08 | 1.25 MB | Download | |||
GER08 | 1.26 MB | Download | |||
ITA08 | 1.25 MB | Download |
ALE3D5FM10CxA00 - 3-ph. e-meter direct, M-Bus
Datasheet | PP26-520 | ALE3D5FM10CxA00 - 3-ph. e-meter direct, M-Bus |
Main Features:
- 3-phase energy meter, 3 × 230/400 VAC 50 Hz
- Direct measuring up to 65 A
- Display of energy, power, voltage and current
- Display of the total active power
- M-Bus interface to retrieve the data
- Reactive power per phase or total, available via M-Bus interface
- Up to 250 meters can be addressed trough primary addresses
- 7-character display
- Can be sealed with sealing cap (optional)
- Accuracy class B according to EN50470-3, Accuracy class 1 according to IEC62053-21
ENG08 | 2.98 MB | Download | |||
FRA08 | 2.99 MB | Download | |||
GER08 | 2.99 MB | Download | |||
ITA08 | 2.99 MB | Download |
AWD3D5WM00C3A00 - 3-ph. e-meter indirect, M-Bus
Datasheet | PP26-521 | AWD3D5WM00C3A00 - 3-ph. e-meter indirect, M-Bus |
Main Features:
- 3-phase energy meter, 3 × 230/400 VAC 50 Hz
- Measurement through a current transformer up to 1500 A
- Display of energy, instantaneous power, voltage and current
- Display of the total active power
- M-Bus interface to retrieve the data
- Reactive power per phase or total, available via M-Bus interface
- Up to 250 meters can be addressed trough primary addresses
- 7-character display
- Can be sealed with sealing cap (optional)
- Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
ENG07 | 3.00 MB | Download | |||
FRA07 | 2.99 MB | Download | |||
GER07 | 2.98 MB | Download | |||
ITA07 | 2.98 MB | Download |
Single-phase energy meter ALD1 with Modbus
Datasheet | PP26-529 | Single-phase energy meter ALD1 with Modbus |
3-phase energy meter ALE3 with Modbus
Datasheet | PP26-527 | 3-phase energy meter ALE3 with Modbus |
3-phase energy meter AWD3 with Modbus
Datasheet | PP26-528 | 3-phase energy meter AWD3 with Modbus |
Mounting Instructions & Installation Guide
AAD1D5F10LRxA00 - 1-ph. e-meter direct, S0
Tutorial | 4 319 5042 0E | AAD1D5F10LRxA00 - 1-ph. e-meter direct, S0 |
Main features
- Single-phase energy meter, 230 VAC 50 Hz
- Direct measurement up to 32 A
- Electromechanical display
- S0 interface
- 7-digit display
- Lead seal possible with cap as accessory
- Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
DE-EN-FR-IT | 0.98 MB | Download | |||
DE-EN-FR-IT - sheets | 0.96 MB | Download |
AAE1D5F10KR3A00 - 1-ph.e-meter direct S0
Tutorial | 4 319 5043 0E | AAE1D5F10KR3A00 - 1-ph.e-meter direct S0 |
Main features
- Single-phase energy meter, 230 VAC 50 Hz
- Direct measurement up to 65 A
- Electromechanical display
- S0 interface
- 7-digit display
- Lead seal possible with cap as accessory
- Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
DE-EN-FR-IT | 0.89 MB | Download | |||
DE-EN-FR-IT - sheets | 0.87 MB | Download |
Mounting Instructions & Users Guide: Single-phase energy meter ALD1 with S0-interface
Tutorial | 4 319 5078 0F | Mounting Instructions & Users Guide: Single-phase energy meter ALD1 with S0-interface |
Mounting Instructions & Users Guide: Single-phase energy meter ALD1 with S-Bus
Tutorial | 4 319 5111 0F | Mounting Instructions & Users Guide: Single-phase energy meter ALD1 with S-Bus |
Mounting Instructions & Users Guide: Single-phase energy meter ALD1 with M-Bus
Tutorial | 4 319 5112 0H | Mounting Instructions & Users Guide: Single-phase energy meter ALD1 with M-Bus |
Single-phase energy meters with integral M-Bus interface for direct measurement, 230 VAC - 50 Hz
Single-phase energy meter with LCD display M-Bus interface, Imax = 32 A, 1 tariff display of active power, voltage and current according to MID directive
GER-ENG-ITA-FRA | 1.01 MB | Download | |||
GER-ENG-ITA-FRA - spreads | 1.05 MB | Download |
Mounting Instructions & Users Guide: Single-phase energy meter ALD1 with Modbus - Unidirectional/Bidirecitional
Tutorial | 4 319 5115 0K | Mounting Instructions & Users Guide: Single-phase energy meter ALD1 with Modbus - Unidirectional/Bidirecitional |
AAE3D5F1xPR3A00 - 3-ph. e-meter direct S0
Tutorial | 4 319 5044 0F | AAE3D5F1xPR3A00 - 3-ph. e-meter direct S0 |
Main features
- 3-phase energy meter, 3 × 230/400 50 Hz
- Direct measurement up to 65 A per phase
- Electromechanical display
- S0 interface
- 7-digit display
- Lead seal possible with cap as accessory
- Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
DE-EN-FR-IT | 0.91 MB | Download | |||
DE-EN-FR-IT - sheets | 0.90 MB | Download |
3-phase energy meter ALE3 with Modbus
Datasheet | PP26-527 | 3-phase energy meter ALE3 with Modbus |
Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with S-Bus
Tutorial | 4 319 5109 0E | Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with S-Bus |
Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with M-Bus
Tutorial | 4 319 5104 0K | Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with M-Bus |
Three-phase energy meters with integral M-Bus interface for direct measurement, 3x 230/400 VAC - 50 Hz
Three-phase energy meter with LCD display M-Bus interface, Imax = 65 A, 2 tariffs display of active power, voltage and current according to MID directive
GER-ENG-FRA-ITA | 1.63 MB | Download | |||
GER-ENG-FRA-ITA - sheets | 1.68 MB | Download |
Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with Modbus - Unidirectional/Bidirectional
Tutorial | 4 319 5113 0H | Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with Modbus - Unidirectional/Bidirectional |
Mounting Instructions & Users Guide: 3-phase energy meter AWD3 with S0-interface
Tutorial | 4 319 5075 0F | Mounting Instructions & Users Guide: 3-phase energy meter AWD3 with S0-interface |
Mounting Instructions & Users Guide: 3-phase energy meter AWD3 with M-Bus
Tutorial | 4 319 5105 0K | Mounting Instructions & Users Guide: 3-phase energy meter AWD3 with M-Bus |
Three-phase energy meters with integral M-Bus interface for current transformer (CT) measurement, 3x 230/400 VAC - 50 Hz
Three-phase energy meter with LCD display M-Bus interface, 5…1'500 A, 1 tariff display of active power, voltage and current according to MID directive
GER-ENG-ITA-FRA | 1.81 MB | Download | |||
GER-ENG-ITA-FRA - sheets | 1.86 MB | Download |
Mounting Instructions & Users Guide: 3-phase energy meter AWD3 with Modbus
Tutorial | 4 319 5114 0G | Mounting Instructions & Users Guide: 3-phase energy meter AWD3 with Modbus |
PCD7.H104S S0 to SBC S-Bus Module
Tutorial | 4 319 5039 0 | PCD7.H104S S0 to SBC S-Bus Module |