PCD2.M127
-
Central processing units (obsolete, replaced by PCD2.M157)
Documentation
Starter Manual xx7
Manual | 26-835 | Starter Manual xx7 |
Hardware xx7 PCD1 and PCD2
Manual | 26-757 | Hardware xx7 PCD1 and PCD2 |
Ethernet TCP/IP for the serie xx7
Reference Guide xx7 (instruction set)
Manual | 26-758 | Reference Guide xx7 (instruction set) |
xx7 System Functions (PCD1 and PCD2)
Manual | 26-797 | xx7 System Functions (PCD1 and PCD2) |
xx7 Modem library
Serial communication with xx7
Hardware configuration including PCD2.W3 and .W6
Preliminary version of the documentation regarding FDL Master-Master communication with xx7
Flyer | Preliminary version of the documentation regarding FDL Master-Master communication with xx7 |
DE | 0.11 MB | Download |
Software
I/O-Builder version 2.4.0
Xx7 only: LON network configurator SNET xx7 version
SFC library
Firmware
PCD2
- What is stored on the micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102068)
- How can the micro SD memory card on the circuit board of a PCD controller be replaced? (FAQ #102067)
- Are devices or software developed from Saia-Burgess Controls affected by the Domain Name System (DNS) vulnerabilities, published with the report name NAME:WRECK? (FAQ #102046)
- Are devices or software developed from Saia-Burgess Controls affected by AMNESIA:33 or SUNBURST? (FAQ #102042)
- Are SBC devices affected by the zero-day vulnerabilities ‘Ripple20’, related to the low-level TCP/IP software library developed by Treck, Inc.? (FAQ #102036)
- Is it possible to use a 16 DI/O module on the base addresse 240? (FAQ #101671)
- Why does the BACnet "Upload/Merge" not work on very busy IP networks? (FAQ #101417)
- Does a PCD automatically generate "gratuitous ARP" telegrams? (FAQ #101045)
- Why can't I connect a PCD2.M480 (with firmware 039) over the serial PGU port? (FAQ #100738)
- The error LED is on and the history contains the message XOB 20 / 25 missing (FAQ #100690)
- I forgot the password for my PCD/PCS! How can I access it again? (FAQ #100639)
- Which extension memory chips are recommended / supported (FAQ #100507)
- Is the XOB 5 "No response from I/O module (I/O Quit Failure)" supported by the PCD3? (FAQ #100501)
- Can the S-Net MPI-Port on the PCD3.M5xx0 and on the PCD2.M5xx0 be used as standard RS-485 Port (FAQ #100500)
- Why can't I connect a PCD over Ethernet after replacing its Ethernet module? (FAQ #100156)
- Can input/output modules be changed under tension (hot-plug)? (FAQ #100111)
PCD1 / _Firmware xx7
xx7 Series
xx7 Series / General
- Why does an EPROM made with GALEP not work on a xx7? (FAQ #100489)
- Firmware downgrade with new Flash Eproms (FAQ #100324)
- Are training courses offered? (FAQ #100032)
- Is there a helpline for technical problems? When can I contact it? (FAQ #100031)
- Are manuals available in English? (FAQ #100030)
- What distinguishes the Saia PCD® xx7 series from other Step®7 programmable controllers on the market? (FAQ #100029)
- Which customers will not find their needs best served by Saia-Burgess Controls AG? (FAQ #100028)
- Which customers will find their needs best served by the Saia PCD® xx7 series? (FAQ #100027)
- What price benefit do I have compared with an original Siemens controller? (FAQ #100026)
xx7 Series / Programming
- It’s possible to use the interrupt Inputs on xx7 CPU’s as normal inputs? (FAQ #101061)
- Why are the LED's RUN HALT and ERROR flashing when going online? (FAQ #100665)
- Is programming over IP supported? (FAQ #100615)
- Which Siemens FC's and FB's can be used on a Saia PCD® xx7-Series? (FAQ #100592)
- Why doesn't the "RAM to ROM" function work on PCD1.M137? (FAQ #100455)
- Does the xx7 have a standard HEAVAC library, like the PG5? (FAQ #100049)
- Can a PC/MPI adapter that does not come from Siemens (e.g. Helmholtz) be used for programming? (FAQ #100047)
- Does programming require any other software than Simatic-Manager? (FAQ #100045)
- Which CPU versions are supported by the xx7 series? (FAQ #100044)
- With which Siemens CPU can an xx7 CPU be compared? (FAQ #100043)
- How long are execution times for instructions? (FAQ #100042)
- How long are execution times for instructions? (FAQ #100041)
- Do function blocks/functions work from the Siemens Standard Library? (FAQ #100039)
- Are the xx7 series controllers really fully compatible? (FAQ #100038)
- Can a Step®7 project edited for Saia PCD® xx7 series run again on an S7? (FAQ #100037)
- Can Step®7 programs from an S7-300/400 run directly on a Saia PCD®, or does anything have to be adapted? (FAQ #100035)
xx7 Series / Hardware configuration
- It’s possible to use the interrupt Inputs on xx7 CPU’s as normal inputs? (FAQ #101061)
- The PCD3.W745 can not be selected in the IO-Builder (FAQ #100520)
- My new hardware configuration for I/Os was not taken over by the xx7. (FAQ #100145)
- How many rows for a PCD2 Slave can I define in the DP slave configuration of a XX7? (FAQ #100131)
- How can local SBC hardware be projected in Simatic-Manager? (FAQ #100053)
- Does programming require any other software than Simatic-Manager? (FAQ #100052)
- Are the xx7 series controllers really fully compatible? (FAQ #100051)
- How do I configure an xx7 system? (FAQ #100050)
xx7 Series / CPU and operating system
- Why it’s no more possible to set the PCD3.Mxx6x in the firmware download mode with the help of the run/stop switch? (FAQ #101948)
- Why the MPI adapter doesn’t work on the MPI port of the PCD3.M5547, PCD3.M5567, PCD3.M5540, PCD3.M5440 or PCD3.5560? (FAQ #101814)
- What are the port numbers which have to be used on Step7 depending of the communication modules? (FAQ #101704)
- The modem library xx7 indicates an error -104 (FAQ #101324)
- It’s possible to use the interrupt Inputs on xx7 CPU’s as normal inputs? (FAQ #101061)
- The "SBC format" changed on Saia PCD® COSinus CPU's (FAQ #101048)
- How to use port 2 of a PCD3.M6xx7 as MPI port (FAQ #100872)
- Can I change the operating system from PCD3 xx7 to SBC standard operation system ? (FAQ #100748)
- Why does the CPU crash when reading the diagnostic buffer? (FAQ #100705)
- Program from PCD7.R400 is not automatically copied into the PCD’s memory (FAQ #100357)
- Firmware downgrade with new Flash Eproms (FAQ #100324)
- What ambient temperature range is the xx7 series approved for? (FAQ #100073)
- What approvals do the xx7 series PCD controllers have? (FAQ #100071)
- What standards are met by the xx7 series regarding EMC guidelines? (FAQ #100070)
- Are run-time meters supported? (FAQ #100069)
- Can access to a xx7 CPU be protected with a password? (FAQ #100068)
- Does the xx7 series have a watchdog relay? How is it activated? (FAQ #100067)
- Are there any modules with interrupt capabilities? (FAQ #100065)
- Are interrupt inputs and fast counter inputs available? (FAQ #100063)
- Does an xx7 series PCD have the same system resources as an original Siemens CPU? (FAQ #100062)
- Does an xx7 series PCD have a buffer battery and integral clock? (FAQ #100060)
- Can the xx7 operating system be updated (FW update)? (FAQ #100059)
- Which system functions are available? (FAQ #100056)
- How long are execution times for instructions? (FAQ #100055)
- Are the xx7 series controllers really fully compatible? (FAQ #100051)
- Which CPU versions are supported by the xx7 series? (FAQ #100044)
- With which Siemens CPU can an xx7 CPU be compared? (FAQ #100043)
xx7 Series / Communication
- What are the port numbers which have to be used on Step7 depending of the communication modules? (FAQ #101704)
- The modem library xx7 indicates an error -104 (FAQ #101324)
- Which Profibus address do I have to choose if the PCD3.M5547 is used as Profi S-IO master or the PCD3.M6547 is used as DP Slave and Master? (FAQ #101178)
- What kind of DP profile do I have to choose when using the PCD3.M6547 as Master and Slave? (FAQ #101177)
- If the PCD3.Mxx7 or PCD2.M5547 has a Profibus configuration it goes often in Stop after startup (FAQ #101176)
- Is it possible to use two different TCP/IP addresses for the two TCP/IP connectors of the PCD2.M5 CPU? (FAQ #101097)
- What is the TCP/IP port number if you want to access the PCD3.Mxxx7 from Step7 over an ADSL router? (FAQ #100796)
- When do I need SFC 14 and 15 for profibus communication? (FAQ #100628)
- Why is the Profibus / LON Communication not working on a PCD7.F772 or PCD7.F802 (FAQ #100563)
- Why is the serial communication on PCD3.Mxxx7 or PCD2.M5xx7 Port 0 not working properly? (FAQ #100554)
- DP-communication between SBC Master and Siemens CP342-5 Slave (FAQ #100396)
- How many MPI-connections can be handled by a XX7? (FAQ #100267)
- Why the XX7 does not support diagnostic messages for SFC14/15 for Profibus DP Networks? (FAQ #100265)
- MPI-communication over serial RS 232 port (FAQ #100220)
- Can M-Bus be implemented on the xx7 series? (FAQ #100201)
- Rules for configuration of Profibus-FDL (FAQ #100166)
- Is it possible to use DP mode "DPV1" on XX7? (FAQ #100162)
- What are the main error sources when Profibus FMS is configured on xx7 series? (FAQ #100160)
- Is it possible to turn off the hardware flow control (RTS-CTS) for RS 232 on a XX7? (FAQ #100158)
- I am not able to establish a modem connection for serial communication on a xx7. (FAQ #100144)
- How many rows for a PCD2 Slave can I define in the DP slave configuration of a XX7? (FAQ #100131)
- Is it also possible to operate GSM modems with the xx7 series PCD? (FAQ #100098)
- Can SMS messages and e-mails also be sent directly with the xx7 series PCD? (FAQ #100097)
- Can a modem be connected to an xx7 series PCD? (FAQ #100096)
- What are the telemaintenance possibilities offered by the xx7 series? (FAQ #100095)
- What things are needed to operate the interface with LON-Works? (FAQ #100094)
- Do xx7 series controllers also offer an interface for LON-Works? (FAQ #100093)
- Is there an interface module for Interbus-S? (FAQ #100092)
- Does the PCD xx7 series also support Profibus-PA? (FAQ #100091)
- What does one do to make a Profibus-DP slave V1 run on the xx7 master? (FAQ #100090)
- What I/O addressing is possible with Profibus-DP master/slave? (FAQ #100088)
- Can an xx7 series controller be both a Profibus-DP master and a DP slave? (FAQ #100087)
- Is Profibus-DP master-master communication possible? How many stations are supported? (FAQ #100086)
- Which serial communication protocols are supported on xx7 systems? (FAQ #100085)
- What transmission speed does the PCD2.M487's integral MPI/S-Net interface support? (FAQ #100084)
- What transmission speed is supported in an MPI network? (FAQ #100083)
- What are the MPI communications capabilities? (FAQ #100082)
- Is it possible to run a Siemens-OP on the MPI interface? (FAQ #100081)
- Can GeniBus be implemented on the xx7 series? (FAQ #100080)
- Can Modbus be implemented on the xx7 series? (FAQ #100079)
- Can SBC S-Bus be implemented on the xx7 series? (FAQ #100078)
- Is Ethernet also supported? (FAQ #100077)
- What are the specific communications capabilities? (FAQ #100076)
- What is the essential, structural design difference between S7 controllers and Saia PCD®? (FAQ #100075)
- What is special about Profibus with Saia PCD®, compared to Siemens or other suppliers? (FAQ #100074)
xx7 Series / Peripherals
- Which connection techniques are available with which connection cross sections? (FAQ #100113)
- How quickly can spare parts be delivered? (FAQ #100112)
- Can input/output modules be changed under tension (hot-plug)? (FAQ #100111)
- In case of repair, can input/output modules be changed quickly? (FAQ #100110)
- What possibilities does the xx7 offer regarding motion control? (FAQ #100109)
- Are there electrically isolated analogue input modules for thermo elements type J/K? (FAQ #100108)
- Are there electrically isolated analogue input modules for temperature (Pt/Ni100/1000) with 4-wire connection? (FAQ #100107)
- Can solenoid valves be connected directly to digital output modules? (FAQ #100106)
- Are the input/output modules electrically isolated? (FAQ #100105)
- What digital/analogue input/output modules are available? (FAQ #100104)
- What bus systems for remote I/O integration are supported by the xx7 series? (FAQ #100103)
- How many I/Os can I connect to the controller? (FAQ #100100)