saia-pcd.com
213
1
SBC software
3
SBC S-Web technology
2
Communication &
Interaction
Communication & Interaction
4
Room automation
Compact modular
Compact
PCD3
compact
PCD3.WACWide Area
Controller
PCD1 E-Line programmable
RIO
7)
I/O data points
PCD3.M2030V6
PCD3.M2130V6
PCD3.M2330A4T1
PCD3.M2330A4T3
PCD3.M2330A4T5
PCD3.M2230A4T3
PCD1.G1100-C15
PCD1.G3600-C15
PCD1.G3601-C15
PCD1.F2611-C15
PCD1.W5300-C15
Onboard (data points)
38 38 14 14 14 14
8 24 24
4
8
Optional I/O slots via expansion modules PCD3.Cxxx
1)
4
4
4
4
4
4
–
–
–
–
–
Maximum number of I/Os
1)
102 102 78 78 78 78
8 24 24
4
8
Maximum number of interfaces (incl. PGU)
3
4
5
5
5
4
3
3
4
4
3
Onboard interfaces
RS-232, PGU up to 115 kBit/s (Port #0)
–
–
–
–
–
–
–
–
–
–
–
RS-485, S-Bus, PGU up to 115 kBit/s (Port #0)
–
–
–
–
–
–
● ● ● ● ●
USB 1.1 device, PGU
● ● ● ● ● ● ● ● ● ● ●
NFC
–
–
–
–
–
–
● ● ● ● ●
Ethernet TCP/IP 10/100 MBit
Fullduplex, autosensing
–
1
1
1
1
–
–
–
–
–
–
RS-485 up to 115 kBit/s (Port #2) or Profi S-Net up to 187.5
kBit/s (Port #2)
●
●
●
●
●
●
●
●
●
●
●
●
–
–
–
–
●
8)
–
●
8)
–
–
–
L
on
W
orks
® FTT10
–
–
–
–
–
–
–
–
–
–
–
Modem P=PSTN, I=ISDN,
PCD: G=GSM/GPRS
–
–
P
I
G G –
–
–
–
–
Optional interfaces
Modbus RTU serial or IP
● ● ● ● ● ●
–
–
–
–
–
Slot for PCD7.F1xxS (A1)
1
1
1
1
1
1
–
–
–
–
–
Uses an external modem via RS-232 interfaces
● ●
–
–
–
–
–
–
–
–
–
1)
I/O slots can be fitted with I/O modules as required (see pages
29/30 and 48/49). The number of data points processed by a PLC
depends on the number of I/O data points per module. A max. 16
data points per module are possible. A PCD can therefore process
a maximum number of data points of 64 I/O slots × 16 data points/
slot = 1024 I/O data points.
2)
A PCDx.R56x memory module is always required to use BACnet®.
Controllers with no Ethernet support BACnet MS/TP using optional
PCD2.F2150 or PCD3.F215 communication modules.
Controller
Memory
module
max. free I/O
slots
PCD3.M3xx0 PCD3.R56x
3
PCD3.M5xx0 PCD7.R56x
4
PCD2.M5xx0 PCD7.R56x
4
PCD1.M2xx0 PCD7.R56x
2
PCD1.M0xx0 PCD7.R56x
---
PCD1.Room PCD7.R56x
1
3)
It is only possible to operate BACnet®-IP and L
on
® IP in parallel
on the PCD3.M5560, PCD3.M6560 and PCD3.M6860 controllers.
4)
The PCD2.F2400 and PCD3.F240 L
on
FTT10 modules are only
available on the following controllers: PCD1.M2020, PCD1.M2120,
PCD1.M2160, PCD1.M2110R1, PCD3.M5560, PCD3.M6560,
PCD3.M6860, PCD2.M5540 from hardware version D, PCD3.M3x40,
PCD3.M5x30, PCD3.M6xx0 from hardware version H
5)
Electrically connected
6)
Electrically isolated
7)
Programmable E-Line modules are optimised for your applica-
tion and therefore do not have all the functions of a Saia PCD
system available with the COSinus operating system. For speci-
fications on the program memory and available PLC media
(flags, registers, etc.), see data sheet.
8)
The onboard RS-485 interface supports "Mode C" with no inter-
preted text for EnOcean, for example