212
saia-pcd.com
Communication & Interaction
Fully modular
Compact modular
PCD3
RIO PCD2
PCD1
I/O data points
PCD3.M3120
PCD3.M3230
PCD3.M3330
PCD3.M5340
PCD3.M5440
PCD3.M5540
PCD3.M5560
PCD3.M6560
PCD3.M6860
PCD3.T665
PCD3.T666
PCD2.M5440
PCD2.M5540
PCD1.M2020
PCD1.M2120
PCD1.M2160
PCD1.M0160E0
PCD1.M2110R1
Onboard (data points)
– – – – – – – – – – – – – 18 18 18 18 24
Onboard I/O slots
1)
4 4 4 4 4 4 4 4 4 4 4 8 8 2 2 2 – 1
Optional I/O slots using expansion modules
1)
– 60 60 60 60 60 60 60 60 3 3 56 56 – – – – –
Maximum number of I/Os
1)
64 1023 1023 1023 1023 1023 1023 1023 1023 256 256 1023 1023 50 50 50 18 40
Maximum number of interfaces
(incl. PGU, USB, Ethernet)
11 10 11 13 13 13 13 13 12 2 11 14 15 7 8 8 4 6
Onboard interfaces
RS-232, PGU up to 115 kBit/s (Port #0)
– – –
● ● ● ● ●
– – –
● ●
– – – – –
USB 1.1 device, PGU
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Ethernet TCP/IP 10/100 MBit
Fullduplex, autosensing/crossing
1 – 1 1 – 1 1 1 2 1 1 – 1 – 1 1 1 1
RS-485 up to 115 kBit/s (Port #2) or Profi S-Net up to
187.5 kBit/s (Port #2)
●
●
●
●
●
●
–
●
●
●
–
–
●
●
●
●
●
●
–
–
●
–
–
–
–
–
●
●
●
●
●
●
●
●
–
–
RS-422/485 up to 115 kBit/s (Port #3) or
RS-485 up to 115 kBit/s electrically isolated (Port #3) or
Profi DP slave, Profi S-Net up to 1.5 MBit/s (Port #10)
–
–
–
–
–
–
–
–
–
●
–
–
–
●
●
–
●
●
–
●
●
–
–
–
–
–
–
–
–
–
–
–
–
–
●
●
–
●
●
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Profibus DP master up to 12 MBits/s
– – – – – – –
●
– – – – – – – – – –
Optional interfaces
Slot C, Profibus DP master 12 MBit/s
– – – – – – – – – – –
● ●
– – – – –
BACnet® IP (with PCDx.R56x modules)
2)
●
–
● ●
–
● ● ● ●
– – –
●
–
● ● ● ●
BACnet® MS/TP
3)
(with PCDx.R56x and PCDx.F215x
modules)
● ● ● ● ● ● ● ● ●
– –
● ● ● ● ●
–
●
L
on
® over IP (with PCDx.R58x modules)
3)
●
–
● ●
–
● ● ● ●
– – –
●
–
● ● ● ●
Modbus RTU serial or IP
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Slot for PCD7.F1xxS (A1/A2)
– – – – – – – – – – – 2 2 1 1 1 1 1
I/O slot #0 for PCD3.F1xx
RS-232 (RTS/CTS, DTR/DSR, CD, RI)
5)
PCD3.F121
● ● ● ● ● ● ● ● ●
–
●
– – – – – – –
RS-485/RS-422 elec. connected
5)
PCD3.F110
● ● ● ● ● ● ● ● ●
–
●
– – – – – – –
RS-485/RS-422 elec. isolated
6)
PCD3.F150
● ● ● ● ● ● ● ● ●
–
●
– – – – – – –
Belimo MP Bus
5)
PCD3.F180
● ● ● ● ● ● ● ● ●
–
●
– – – – – – –
I/O slot #0… #3 for PCD3
PCD3.F210 RS-485/422
5)
+ opt. PCD7.F1xxS
4 4 4 4 4 4 4 4 4 – – – – – – – – –
PCD3.F215 BACnet MS/TP...
5)
+ opt. PCD7.F1xxS
4 4 4 4 4 4 4 4 4 – – – – – – – – –
PCD3.F221 RS-232 full
5)
+ opt. PCD7.F1xxS
4 4 4 4 4 4 4 4 4 – – – – – – – – –
PCD3.F240 L
on
FTT10
6)
+ opt. PCD7.F1xxS
4)
– – – 4 4 4 4 4 4 – – – – – – – – –
PCD3.F261 DALI incl. Bus power supply
6)
4 4 4 4 4 4 4 4 4 – 4 – – – – – – –
PCD3.F27x M-Bus Master
5)
4 4 4 4 4 4 4 4 4 – 4 – – – – – – –
PCD3.F281 Belimo MP Bus
+ opt. PCD7.F1xxS
5)
4 4 4 4 4 4 4 4 4 – – – – – – – – –
I/O slot #0… #3 for PCD2 and
slot #0… #1 for PCD1 and
PCD2.F2100 RS-485/422
5)
+ opt. PCD7.F1xxS
– – – – – – – – – – – 4 4 2 2 2 – 1
PCD2.F2150 BACnet MS/TP...
5)
+ opt. PCD7.F1xxS
– – – – – – – – – – – 4 4 2 2 2 – 1
PCD2.F2210 RS-232 full
5)
+ opt. PCD7.F1xxS
– – – – – – – – – – – 4 4 2 2 2 – 1
PCD2.F2400 L
on
FTT10
6)
+ opt. PCD7.F1xxS
4)
– – – – – – – – – – – – 4 2 2 2 – 1
PCD2.F2610 DALI incl. Bus power supply
6)
– – – – – – – – – – – 4 4 2 2 2 – 1
PCD2.F27x0 M-Bus Master
5)
– – – – – – – – – – – 4 4 2 2 2 – 1
PCD2.F2810 Belimo MP Bus
5)
+ opt. PCD7.F1xxS
– – – – – – – – – – – 4 4 2 2 2 – 1
Slots for modem (A1/A2)
– – – – – – – – – – – 2 2 – – – – –
Using an external modem
via RS-232 interfaces
● ● ● ● ● ● ● ● ●
– –
● ● ● ● ● ● ●
2.2
An overview of Saia PCD®communication systems