software Web Connect is needed and to generate project containing a PCD internal Web server the Web Builder is required. Both tools are part of the Controls Suite. S-Bus as communication protocol The SBC S-Bus is an integral component of the Firmware. Many other protocols are supported through special drivers (e.g. FBoxes). Communication modules do not require additional [...] addresses by its physical location All I/Os are addressed statically on the internal I/O bus. Therefore the addresses of mounted I/O modules is depending on its physical location. Each module has a I
On the CPU PCD2.M480 can be plugged two PCD7.F655 Ethernet cards. This feature allows you to program either Ethernet redundancy by creating an reduced "IP Firewall" or to realise an Ether-S-Bus to Ether-S-Bus gateway.
It is possible capturing the traffic on a Ethernet network and stop this capture based on a specific condition, like e.g. the lack of Ether-S-Bus telegrams from a specific station for a certain time. However, this can't be done within Wireshark itself, but by using its command line tool TShark which is piped to a Perl script.
. How to configure the S-Bus address on a ALE3? (FAQ #101476) The S-Bus address of an ALE3 with Serial-S-Bus interface can be configured by the following procedure. Setting the S-Bus address Navigate to the "Tariff 1 total" (the blue bar must be right below "T1total"; it can be moved with the "arrow
. How to configure the S-Bus address on a ALE3? (FAQ #101476) The S-Bus address of an ALE3 with Serial-S-Bus interface can be configured by the following procedure. Setting the S-Bus address Navigate to the "Tariff 1 total" (the blue bar must be right below "T1total"; it can be moved with the "arrow
now accept AcknowledgeAlarm service requests, which use complete wildcards as timestamps. Main corrections All PCD’s: On S-Bus data mode, if S-Bus CRC contains a S-Bus DLE as last character then S-Bus telegram is incorrect and not accepted from S-Bus recipient. (Since FW 1.28.20) All PCD’s: Not all bytes are transmitted when working with MC4 or MC5 mode on F2xxx module All PCD’s [...] before with SCOB All PCD’s: Profibus communcation using onboard FDL port. The FCS test for SD2 telegram was not implemented correctly. All PCD’s: When S-Bus IP Nodelist is used it’s possible that the
. Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026) It’s possible that the some of the S-Bus telegrams transferred from the PCD S-Bus master to the S-Bus slaves over RS485 are malformed, and the S-Bus slave does reject the request from the master. This could lead to the situation that for example the PCD S-Bus master don’t receive actual values from E-Line RIO’s or that the program download of a PCD program from the PC to a Slave PCD which is
. PCD2 / _Firmware Classic Why the RS-485 S-Bus [...] possible that the some of the S-Bus telegrams transferred from the PCD S-Bus master to the S-Bus slaves over RS485 are malformed, and the S-Bus slave does reject the request from the master. This could lead to the situation that for example the PCD S-Bus master don’t receive actual values from E-Line RIO’s or that the program download of a PCD program from the PC to a Slave PCD which is located behind
. Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026) It’s possible that the some of the S-Bus telegrams transferred from the PCD S-Bus master to the S-Bus slaves over RS485 are malformed, and the S-Bus slave does reject the request from the master. This could lead to the situation that for example the PCD S-Bus master don’t receive actual values from E-Line RIO’s or that the program download of a PCD program from the PC to a Slave PCD which is