Product Category Remote I/O PCD7.Lxxx S-Bus RIO L2xx: Digital output RIO [...] PCD7.L2xx S-Bus remote I/O's, couplers [...] -100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room
PCD7.L2xx S-Bus remote I/O's, couplers [...] -100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room [...] with use of the PCD7.L60x S-Bus room controllers (not LON
controllers with S-Bus and Modbus Configurable room controller with BACnet MS/TP interface and commissioning tool [...] 7.LRxxx Combinable room control system with serial S-Bus interface for fan-coil and air quality control applications PCD7.L60x-1 Combinable room control system with Lon [...] room conctrol units PCD7.L64x Compact room controller with serial S-Bus interface Saia
about how to plan S-Bus networks can be found in the documentation area. A system partner provides a tool that allows to optmize the S-Bus communication by setting priorities for different telegrams in [...] /UDP. CPU's can be configured as gateway, so they can link several networks. Standard on all Classic CPU's. Details about how to plan S-Bus networks can be found in the documentation area. A system partner provides a tool that allows to optmize the S-Bus communication by setting priorities for different telegrams in form of an Excel sheet. Please refer to www.engiby.ch for more details. All PCD CPU's
E-Mon BLACK PQA - Saia PCD® Power Quality Analyser PQA - Saia PCD® Power Quality Analyser Energy meters with integral serial S-Bus interface [...] power for every phase and for the three phases. SBC S-Bus M-Bus Modbus S0-interface Saia PCD S0 pulse counters Energy controller for electric cabinet Energy controller with S-Monitoring function Accessories for Energy Meters
The PCD7.LRxx-P5 IRM room controller can be operated on the RS485 interface as an S-Bus master. The PCD7.LRxx-P5 IRM room controller supports all S-Bus telegrams except the 2 telegrams: Read Input Write Output This means that it is not possible with the PCD7.LRxx-P5 IRM room controller, to read from the S-Bus Slave devices directly via S-Bus inputs and to write the outputs of the S-Bus Slave devices. If S-Bus Slave devices are used which use the S-Bus telegrams 'Read Input' and 'Write Output', then replace these devices with E-Line RIOs.
Due to an error on the E-Line S-Bus communication library < 1.2.110, the S-Bus communication stops after a certain time, if the communication mode ‘on Event’ or ‘on Sampling time n’ has been selected on the S-Bus communication FBoxes
Due to an error on the communication library 2.7.370, the S-Bus communication stops after a certain time or after the download of the program, if the communication mode ‘on Event’ or ‘on Sampling time n’ has been selected on the S-Bus communication FBoxes
It is possible to convert all the variable from a S-Bus driver to Ether S-Bus driver if an existing project has to be used on another terminal type (e.g. PCD7.D786 convert to PCD7.D786ET)!
SBC OPC Server for SBC S-Bus