CONTRÔLEUR POUR VENTILO-CONVECTEUR Modules K.DDC.L755 and K.DDC.L757 avec protocole S-Bus
8.K100 (for PCD8.P100) and .K110 (for PC's) are obsolete and replaced by PCD8.K101 and .K111 respectively. The new cables support as well the S-Bus protocol and are required to program PCD1.Mxxx, PCD2.M150, PCD [...] be detected. In this case, the only possibility for going online in PGU mode is using the USB cable (or using an S-Bus PGU port which had been configured in the hardware settings previously [...] ! PCD7.D761 / D763 loses communication on Profi S-Bus! (FAQ #100477) On a Profi S-Bus network when PCD7.D76_ terminals
communication errors when connecting a PCD/PCS in "Secure S-Bus Data Mode"? (FAQ #101180) In case a "non Saia PCD® COSinus" PCD or PCS1 system is connected with "Secure S-Bus Data mode" (e.g. over a serial cable or over modem) from time to time a telegram is not answered correctly. Symptom A PCD or a PCS connected with another system (e.g. PC or another PCD system) using the "Secure S-Bus Data mode" does not answer a telegram from time to time. This can e.g. be seen by a red LED on transmit or receive FBoxes
communication errors when connecting a PCD/PCS in "Secure S-Bus Data Mode"? (FAQ #101180) In case a "non Saia PCD® COSinus" PCD or PCS1 system is connected with "Secure S-Bus Data mode" (e.g. over a serial cable or over modem) from time to time a telegram is not answered correctly. Symptom A PCD or a PCS connected with another system (e.g. PC or another PCD system) using the "Secure S-Bus Data mode" does not answer a telegram from time to time. This can e.g. be seen by a red LED on transmit or receive FBoxes
Product Category Remote I/O PCD7.Lxxx S-Bus RIO L1xx: Digital input RIO [...] PCD7.L1xx S-Bus remote I/O's Documentation [...] later) firmware version the register 17 can be used to define a lamella running time after stop position, see FAQ 101415 . Be careful if you place a lot of L1xx or L3xx S-Bus input modules
PCD7.L1xx S-Bus remote I/O's Documentation [...] later) firmware version the register 17 can be used to define a lamella running time after stop position, see FAQ 101415 . Be careful if you place a lot of L1xx or L3xx S-Bus input modules [...] -100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room
Product Category Remote I/O PCD7.Lxxx S-Bus RIO L2xx: Digital output RIO [...] PCD7.L2xx S-Bus remote I/O's, couplers [...] -100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room
PCD7.L2xx S-Bus remote I/O's, couplers [...] -100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room [...] with use of the PCD7.L60x S-Bus room controllers (not LON
Product Category Remote I/O PCD7.Lxxx S-Bus RIO L3xx: Analogue input RIO [...] PCD7.L3xx S-Bus remote I/O's Documentation These leaflets are more up to date than the manual and TI, please first refer to the leaflet. Good to know Be careful if you place a lot of L1xx or L3xx S-Bus input modules on
PCD7.L3xx S-Bus remote I/O's Documentation These leaflets are more up to date than the manual and TI, please first refer to the leaflet. Good to know Be careful if you place a lot of L1xx or L3xx S-Bus input modules on [...] -100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room