M-Bus on Saia PCD® PCD2.F27x0 and PCD3.F27x Introduction A PCD1.M2, PCD2.M5 or PCD3 can act as M-Bus Master using the according connection interface module PCD3.F27x or PCD2.F27x0. Module overview There exist 4 different M-Bus module types to be plugged into PCD I/O slot 0..3. The difference between the types is the amount of M-Bus slaves which can be connected per module (on the two ports) Modules for the PCD1.M2 and PCD2.M5 PCD2.F2700 PCD
Download of Bacnet project or Lonip projects fails
M2 for PCD3.M5/M6-, PCD2.M5-, PCD1.M2- and PCD1.M0 controllers. The PCD3.R58x module is available for I/O slots. A “LON communication module” is also required to connect the LON FTT10. This module provides PCD controllers with a LonWorks® interface but without a router function. PCD1.M2 controllers require the PCD2.F2400 module and PCD3 controllers (see supported PCD3 devices in the table belwo [...] of a PCD connected to a BACnet/IP network which could lead to a missinterpretation. Although BACnet is supported by a PCD3 or a PCD2.M5xx0 and LON on IP will be suppored in future, it won't be possible
LonIp FW and coresponding PCD FW for PCD1.M2xx0, PCD2.M4x60, PCD3.Mxx60 Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx or 1.26.xx or newer to a not compatible PCD.
Package does include the FW for the PCD1.M2, PCD2.M5, PCD3.M and the LonIP FW. This firmware does support the modules PCD7.W600 and PCD7.R610 Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD.
LonIp FW and coresponding PCD FW for PCD1.M2xx0, PCD2.M4x60, PCD2.M5xx0, PCD3.Mxxx0, PCD3.Mxx60 Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx or 1.26.xx or newer to a not compatible PCD.
LonIP and PCD FW for PCD1.M2xx0, PCD3.Mxx60, PCD3.Mxxx0, PCD2.M5xx0 which could be used as maintenance firmware for PCD's with 4 MB firmware memory
trace back a crash, a dump of the whole memory (SRAM, DRAM and FLASH) of a PCD can be done. This FAQ does apply to PCD1.M2, PCD2.M480, PCD2.M5xxx, PCD3 (including PCD3.Mxx60) and PCD [...] Tool.exe in the PG5 directory. PCD1.M2 PCD2.M480 PCD2.M5 PCD3 PCD3.Mxx60 (fast CPU) PCD7.D4xxxT5F (programmable MB-panels) Usage of the old stand alone tool SaiaDump.exe: This tool [...] Dump.exe) Download the archive "SaiaDump_V1_3_006.zip" from this FAQ Unpack the *.zip archive on your PC or Laptop In the extracted folder "SaiaDump" you'll find several batch files (e.g. RUN_DUMP_PCD1M
einsetzbar PCD2.M5540 Maximal zwei Romutec HNBE einsetzbar PCD3.M5xxx Maximal zwei Romutec HNBE einsetzbar PCD3.M3xxx Maximal zwei Romutec HNBE einsetzbar Die S-Bus Handnotbedienebene [...] . Speicherabzug einer PCD (mit Saia PG5® COSinus Firmware) erstellen (FAQ #100866) Die History-Einträge einer PCD3, PCD2.M480 oder [...] beziehen Sie sich auf den Originaleintrag! Arbeitsweise Für einen kompletten Speicherabzug ("memory dump") einer PCD3 (oder PCD2.M480 bzw PCD2.M5xxx) stellt Saia-Burgess Controls AG ein kleines