Saia PCD3 modular programmable controllers PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupts, RS-232, 2x RS-485 for Profi-S-Net/MPI/S-Bus
PCD3 processor unit with Ethernet TCP/IP
PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 2 MByte user program, 1 MByte SRam extension memory, 128 MByte user Flash memory with file system, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupts, RS-232, 2× RS-485 for Profi-S-Net/MPI/S-Bus
The external MPI adapter which can be connected to the MPI Port of the PCD does need to be supplied with 24VDC. Depending of the hardware version of the PCD, on some FW this 24VDC supply on the MPI doesn’t work.
If the PCD2/3.W220Z18 card is plugged in to a ‘Power PCD‘ or a PCD2.C1000 or PCD2.C2000 and if all 8 analog inputs channels of the PCD2/3.W220Z18 module are connected to 8 PT100 sensors then the measured PT100 temperature values of the 8 channels are not correct. ‘Power PCD’s’ are: PCD1.M2x20, PCD1.M2160, PCD1.M2220-C15 PCD2.M5540, PCD2.M5440, PCD2.M4160, PCD2.M4560 PCD3.Mxx60 To solve the issue, use and connect only up to 7 PT100 sensors to the PCD2/3.W220Z18 or do use a PCD2/3.W350 module, if all 8 PT100 are needed.
for PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD2.M5xx0, PCD3.Mxxx0, PCD3.Mxx60, PCD3.M6860, PCD3.M6880, PCD3.T665, PCD3.T666, PCD3.T668, PCD7.D4xxxT5F, PCD7.D4xxV, PCD7.D4xxD, PCD7.D4xxWTPF, PCD7.D443WTxR and [...] 4x60 PCD2.M5xx0 PCD3.Mxxx0 PCD3.Mxx60 PCD3.M6860 and PCD3.M
for PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD2.M5xx0, PCD3.Mxxx0, PCD3.Mxx60, PCD3.M6860, PCD3.M6880, PCD3.T665, PCD3.T666, PCD3.T668, PCD7.D4xxxT5F, PCD7.D4xxV, PCD7.D4xxD, PCD7.D4xxWTPF, PCD7.D443WTxR and [...] 4x60 PCD2.M5xx0 PCD3.Mxxx0 PCD3.Mxx60 PCD3.M6860 and PCD3.M
5440 FW 1.16.52 FW >= 1.16.69 HW F ok ok HW G1 No 24V on MPI ok PCD3.M5560 FW 1 [...] On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052) [...] Why the MPI adapter doesn’t work on the MPI port of the PCD3.M5547, PCD3.M5567, PCD3.M5540, PCD3.M5440 or PCD3.5560? (FAQ #101814)
5440 FW 1.16.52 FW >= 1.16.69 HW F ok ok HW G1 No 24V on MPI ok PCD3.M5560 FW 1 [...] On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052) [...] Why the MPI adapter doesn’t work on the MPI port of the PCD3.M5547, PCD3.M5567, PCD3.M5540, PCD3.M5440 or PCD3.5560? (FAQ #101814)
5440 FW 1.16.52 FW >= 1.16.69 HW F ok ok HW G1 No 24V on MPI ok PCD3.M5560 FW 1 [...] On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052) [...] Why the MPI adapter doesn’t work on the MPI port of the PCD3.M5547, PCD3.M5567, PCD3.M5540, PCD3.M5440 or PCD3.5560? (FAQ #101814)