be used with terminal kits PCD7.D162 (including a PCD2 [...] MC5 mode on F2xxx module All PCD’s: RS485 driver keep holding bus after a while All PCD’s: Http request ‘is modified’ is not handled correctly on the PCD Web-Server which lead to the effect that [...] (CVE-2017-9628) All PCD's: The Modbus CSF CloseSRPort does not free the port then a open/SASI call give an error and the port does not work. PCD1.M2xx0 PCD1.M22x0 PCD2.M4x60: PCD can crash while power down
MC5 mode on F2xxx module All PCD’s: RS485 driver keep holding bus after a while All PCD’s: Http request ‘is modified’ is not handled correctly on the PCD Web-Server which lead to the effect that [...] (CVE-2017-9628) All PCD's: The Modbus CSF CloseSRPort does not free the port then a open/SASI call give an error and the port does not work. PCD1.M2xx0 PCD1.M22x0 PCD2.M4x60: PCD can crash while power down [...] SRPort does not free the port then a open/SASI call give an error and the port does not work. PCD1.M2xx0 PCD1.M22x0 PCD2.M4x60: PCD can crash while power down when XOB 0 is programmed. PCD1.M2xx0 PCD
minimal system requirements are: PG5 2.0.200 PCD Firmware 1.16.48 Modules supporting a firmware update: PCD2.F26xx PCD2.F27xx PCD3.F26x PCD [...] minimal system requirements are: PG5 2.0.200 PCD Firmware 1.16.48 Modules supporting a firmware update: PCD2.F26xx PCD2.F27xx PCD3.F26x PCD [...] M-Bus on Saia PCD® PCD2.F27x0 and PCD3.F27x Introduction A PCD1.M2, PCD2.M5 or PCD
M2 for PCD3.M5/M6-, PCD2.M5-, PCD1.M2- and PCD1.M0 controllers. The PCD3.R58x module is available for I/O slots. A “LON communication module” is also required to connect the LON FTT10. This module provides PCD controllers with a LonWorks® interface but without a router function. PCD1.M2 controllers require the PCD2.F2400 module and PCD3 controllers (see supported PCD3 devices in the table belwo [...] of the LonWorks interface devices PCD2.F240, PCD3.F2400 and the LonWorks memory device PCD7.R582 was discontinued at the end of 2021 and the devices are no longer available. As a replacement, we
LonIp FW and coresponding PCD FW for PCD1.M2xx0, PCD2.M4x60, PCD3.Mxx60 Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx or 1.26.xx or newer to a not compatible PCD.
Package does include the FW for the PCD1.M2, PCD2.M5, PCD3.M and the LonIP FW. This firmware does support the modules PCD7.W600 and PCD7.R610 Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx to a not compatible PCD.
LonIp FW and coresponding PCD FW for PCD1.M2xx0, PCD2.M4x60, PCD2.M5xx0, PCD3.Mxxx0, PCD3.Mxx60 Do use at least the PG5 firmware downloader version 2.1.311 or newer (included in PG5 patch 2.1.311 or newer) to prevent the loading of the FW 1.24.xx or 1.26.xx or newer to a not compatible PCD.
trace back a crash, a dump of the whole memory (SRAM, DRAM and FLASH) of a PCD can be done. This FAQ does apply to PCD1.M2, PCD2.M480, PCD2.M5xxx, PCD3 (including PCD3.Mxx60) and PCD [...] 5 2.1.210): This tool does open a small window which allow to define the device type and the destination folder where the dump files will be stored. The device field does show the PCD which is [...] : - RUN_DUMP_PCD1M2xx0.bat for PCD1.M2xx0 - RUN_DUMP_PCD3Mxxx0.bat for PCD2.M5xx0 and PCD3 systems - RUN_DUMP_PCD3Mxx6x.bat for PCD3.Mxx60 (fast CPU) systems After a successful dump a new
XX7_5_15_02.jar Datei behoben. PG5 2.1.300 oder höher enthält das überarbeitete Java Applet. Der Austauch des Applet wird im FAQ 101878 beschrieben Als vorläufige Lösung ist die Freigabe der IP- Adresse der PCD [...] In seltenen Fällen ist die Ether-S-Bus Kommunikation bei Programmen die aus PG5 2.0 oder 2.1.200 in die PG5 2.1.210 importiert wurden nach einem Rebuild All und anschließendem Download nicht mehr in [...] störbelasteten Umfeldern können diese Telegramme in den Störungen unter gehen. Abhilfe schafft die kontinuierliche Kommunikationsbibliothek V1.22A. Die Zustände der HNBE werden ständig zwischen der PCD und der
It is correct that the indication of a low battery will appears earlier due to more accurate prediction on a new Saia PCD® COSinus system than before on a PCD2/1.M1xx.