3-phasige Energiezähler mit M-Bus Schnittstelle
Dokumentation
System Catalogue : S-Monitoring (Energy Meters)
Extract | 26-215_A0400 | System Catalogue : S-Monitoring (Energy Meters) |
ALE3D5FM10CxA00 - 3-ph. e-meter direct, M-Bus
Datasheet | PP26-520 | ALE3D5FM10CxA00 - 3-ph. e-meter direct, M-Bus |
Main Features:
- 3-phase energy meter, 3 × 230/400 VAC 50 Hz
- Direct measuring up to 65 A
- Display of energy, power, voltage and current
- Display of the total active power
- M-Bus interface to retrieve the data
- Reactive power per phase or total, available via M-Bus interface
- Up to 250 meters can be addressed trough primary addresses
- 7-character display
- Can be sealed with sealing cap (optional)
- Accuracy class B according to EN50470-3, Accuracy class 1 according to IEC62053-21
ENG08 | 2.98 MB | Download | |||
FRA08 | 2.99 MB | Download | |||
GER08 | 2.99 MB | Download | |||
ITA08 | 2.99 MB | Download |
ALE3B5FM00C3A00 - 3-ph. e-meter direct, M-Bus - bidi
Datasheet | PP31-024 | ALE3B5FM00C3A00 - 3-ph. e-meter direct, M-Bus - bidi |
3-phase energy meter ALE3 with M-Bus (bidirectional)
Order number
MID version: ALE3B5FM00C3A00
Sealing cap: 4 104 7485 0
Specifications
- 3-phase energy meter, 3 × 230 / 400 VAC 50 Hz
- Direct metering to 65 A in both directions of current
- Display of the active power, voltage and current per phase
- Display of the total active power
- M-Bus interface used to query data
- Idle power per phase or total available via the interface
- Up to 254 energy meters can be connected to a single M-Bus interface.
- 7-digit LCD display for energy supply and feeding back
- Can be sealed and is provided with a sealing cap as an accessory
- Accuracy class B in accordance with EN50470-3, Accuracy class 1 in accordance with IEC62053-21
ENG05 | 3.63 MB | Download | |||
FRA05 | 3.64 MB | Download | |||
GER05 | 3.64 MB | Download | |||
ITA05 | 3.64 MB | Download |
AWD3D5WM00C3A00 - 3-ph. e-meter indirect, M-Bus
Datasheet | PP26-521 | AWD3D5WM00C3A00 - 3-ph. e-meter indirect, M-Bus |
Main Features:
- 3-phase energy meter, 3 × 230/400 VAC 50 Hz
- Measurement through a current transformer up to 1500 A
- Display of energy, instantaneous power, voltage and current
- Display of the total active power
- M-Bus interface to retrieve the data
- Reactive power per phase or total, available via M-Bus interface
- Up to 250 meters can be addressed trough primary addresses
- 7-character display
- Can be sealed with sealing cap (optional)
- Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21
ENG07 | 3.00 MB | Download | |||
FRA07 | 2.99 MB | Download | |||
GER07 | 2.98 MB | Download | |||
ITA07 | 2.98 MB | Download |
Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with M-Bus
Tutorial | 4 319 5104 0K | Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with M-Bus |
Three-phase energy meters with integral M-Bus interface for direct measurement, 3x 230/400 VAC - 50 Hz
Three-phase energy meter with LCD display M-Bus interface, Imax = 65 A, 2 tariffs display of active power, voltage and current according to MID directive
GER-ENG-FRA-ITA | 1.63 MB | Download | |||
GER-ENG-FRA-ITA - sheets | 1.68 MB | Download |
Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with M-Bus (bidirectional)
Tutorial | 32303824-001 - Index E | Mounting Instructions & Users Guide: 3-phase energy meter ALE3 with M-Bus (bidirectional) |
Three-phase energy meters with integral M-Bus interface for direct measurement, 3x 230/400 VAC - 50 Hz
Three-phase two-way energy meter with LCD display M-Bus interface, Imax = 65 A display of active power, voltage and current according to MID directive
GER-ENG-ITA-FRA | 1.98 MB | Download | |||
GER-ENG-ITA-FRA - sheets | 2.03 MB | Download |
Mounting Instructions & Users Guide: 3-phase energy meter AWD3 with M-Bus
Tutorial | 4 319 5105 0K | Mounting Instructions & Users Guide: 3-phase energy meter AWD3 with M-Bus |
Three-phase energy meters with integral M-Bus interface for current transformer (CT) measurement, 3x 230/400 VAC - 50 Hz
Three-phase energy meter with LCD display M-Bus interface, 5…1'500 A, 1 tariff display of active power, voltage and current according to MID directive
GER-ENG-ITA-FRA | 1.81 MB | Download | |||
GER-ENG-ITA-FRA - sheets | 1.86 MB | Download |
EPLAN Produktmakros, DWG und DXF Dateien können hier heruntergeladen werden.
FBoxen zum Auslesen der Energiezähler mit Fulpa (MBus Treiber)
FBoxen für PG5 1.4 kann hier heruntergeladen werden
FBoxen für PG5 2.0 kann hier heruntergeladen werden
Good to know
Falls Sie die M-Bus FBox library von Engiby verwenden: installieren Sie obenstehende SBC M-Bus Libary nicht parallel, sondern aktualisieren Sie die M-Bus Library von Engiby (welche die SBC M-Bus Energiezähler unterstützt).
Der M-Bus Treiber für SBC Energiezähler ALD/ALE/AWD mit M-Bus 2.6.113 zeigt nun auch das Total aktiver und reaktiver Strom, siehe FAQ 101604.
Der M-Bus Treiber für SBC Energiezähler ALE/AWD mit M-Bus (version 2.6.104)
enthält eine Korrektur, erklärt in FAQ 101604.