Upgrade kit Saia PCD4.U100
The Saia PCD4.U100 module makes it possible to connect existing Saia PCD4 I/O modules to the latest Saia PCD3
and PCD2.M5 systems. By upgrading to the latest Saia PCD® system, you can increase the availability and reliability
of the system. It is also possible to enhance systems with Automation Server functions and thus prepare them
for the future. Installation is easy: Replace Saia PCD4 CPU with PCD4.U100, install Saia PCD3 or PCD2 CPU, connect
new or existing PCD4 I/Os and you’re ready to go.
Regardless of whether IL or FUPLA programming is used, the user programs can be directly transferred to new CPUs
with small program adjustments in PG5, i.e., with minimum programming effort.
System properties
Supports Saia PCD3.Mxxx0 and
Saia PCD2.M5xx0
Program can be easily transferred
Existing I/Os can still be used
System overview
Technical overview
Supported PCD types
PCD3.Mxxx0 All PCDs with I/O bus connection PCD2.M5xx0 (no extension PCD2.C1000/C2000)
Supported PCD4 I/O modules
All PCD4 I/O modules except PCD4.Hx are supported
Number of PCD4 I/O modules
See technical documentation of the PCD4 systems
Max. number of PCD2/3 I/O modules
8 (only PCD3.C200 module carriers can be used in combination with the PCD3.M system)
Features
Increase system availability with a minimum of effort:
Replace old PCD4 CPUs that are no longer available with the latest Saia PCD®
CPUs. The reliability and availability of an existing system or controller can be increased in a time-saving manner and cost-efficiently
by using a new CPU.
Benefits of the automation server functions:
NewWeb/IT functions can also be made available in existing systems with PCD4
systems. Existing program structures can be copied across with small program adjustments and can still be used.
Expand PCD4 systems with new PCD2/3 I/O modules. Up to 8 additional PCD2/3 I/O modules can be integrated into existing
systems by replacing the CPUs.
Retaining the wiring:
The system can be upgraded without costly rewiring of the I/Os.
Short upgrade period:
The CPU is replaced quickly and the system is available again in a very short period of time.
This way the wiring effort can be delayed to a later point in time.
Order details
Type
Description
PCD4.U100
PCD4 upgrade kit basic module (without I/O bus cable)
PCD3.K106
I/O bus extension cable for Saia PCD3
PCD2.K106
I/O bus extension cable for Saia PCD2