correctly. The EnOcean FBox library version 2.6.147 contains modifications listed in FAQ 101765 . The Modbus FBox library version 2.6.220 can be addressed with the S-Bus address, see FAQ [...] -protocols are disabled by default on the deivce configurator of new PG5 projects: - S-Bus over TCP/IP - FTP - HTTP (Web-Server) PG5 projects made with precedent version of PG5 2.1 are upward compatible [...] default on the deivce configurator of new PG5 projects: - S-Bus over TCP/IP - FTP - HTTP (Web-Server) - The user has to turn on the appropriate IP protocols deliberately in the Device
correctly. The EnOcean FBox library version 2.6.147 contains modifications listed in FAQ 101765 . The Modbus FBox library version 2.6.220 can be addressed with the S-Bus address, see FAQ [...] transfer from the S-Bus driver to the Ether-S-Bus driver. See the description below Procedure for the conversion of a PCD8.D81W project Open the project and move the SBC S-Bus driver from ASP to MSP. Convert the panel from Vxxx rev 4 to VTxxx ETH. Drag and drop the driver "SBC Ethernet S-Bus" to the Ethernet port. Open the
firmware. Solution At the moment the dynamic space has to be defined >=1000 and Timeout -> TS-Delay -> TN-Delay -> Break length ) If you want to disable the "Secure S-Bus Data mode" If you [...] ) Why does the FBox "SASI S-Bus Extended" not work (for assigning a gateway master port)? (FAQ #101399) There are several reasons to use the FBox "SASI S-Bus Extended" (see FAQ 101400). But there is a limitation that it is not possible to use this FBox for re-assigning a port as Gateway master port on Saia PCD® COSinus systems
correctly. The EnOcean FBox library version 2.6.147 contains modifications listed in FAQ 101765 . The Modbus FBox library version 2.6.220 can be addressed with the S-Bus address, see FAQ [...] transfer from the S-Bus driver to the Ether-S-Bus driver. See the description below Procedure for the conversion of a PCD8.D81W project Open the project and move the SBC S-Bus driver from ASP to MSP. Convert the panel from Vxxx rev 4 to VTxxx ETH. Drag and drop the driver "SBC Ethernet S-Bus" to the Ethernet port. Open the
firmware. Solution At the moment the dynamic space has to be defined >=1000 and Timeout -> TS-Delay -> TN-Delay -> Break length ) If you want to disable the "Secure S-Bus Data mode" If you [...] ) Why does the FBox "SASI S-Bus Extended" not work (for assigning a gateway master port)? (FAQ #101399) There are several reasons to use the FBox "SASI S-Bus Extended" (see FAQ 101400). But there is a limitation that it is not possible to use this FBox for re-assigning a port as Gateway master port on Saia PCD® COSinus systems
2? 29.01.2019 #102029 - Why can the PCD7.LRxx-P5 IRM room controller as S-Bus master, not read/write datas (inputs and outputs) from S-Bus slave devices via S-Bus [...] ? 16.11.2018 #102026 - Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used [...] ? 29.11.2017 #102008 - PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or
. Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026) It’s possible that the some of the S-Bus telegrams transferred from the PCD S-Bus master to the S-Bus slaves over RS485 are malformed, and the S-Bus slave does reject the request from the master. This could lead to the situation that for example the PCD S-Bus master don’t receive actual values from E-Line RIO’s or that the program download of a PCD program from the PC to a Slave PCD which is
01 0271 0022 fexible cable Note: If the bautrates isn't greater than 187,5 bautes (for ex. Profi S-Bus with PCD3.M3xx / PCD7.D7xx) you can use other more advantegeous cable, especially [...] and connector as the communication speed goes up to 12 Mbautes! Those cable and connectors are used in Profibus DP, FMS, Profis S-Bus, Profi S-IO and MPI! Wiring and Network [...] for the port 3 of the PCD3.M5540 as Serial-S-Bus RS485 connection (Serial-S-Bus) between PCD3.M5540 port 3 (S-Net D-Sub used as RS485 Serial-S-Bus) and PCD2.M5540 port 2 (connector block X
Ether-S-Bus communication or Ethernet communication in general, we recommend using the free software Wireshark ( www.wireshark.org ). This is an open source analyzer (including matching log file creator WinPcap). The Wireshark analyzer is able to dissect Ether-S-Bus from version 1.1 on. For more information please refer to the according FAQ #100569 . Good to know In June 2006 the new
. Why does my RS-232 S-Bus communication not work with the PCD2.F2xx0 and PCD3.F2xx module? (FAQ #101775) The RS-232 S-Bus [...] V020) it may be, that the S-Bus communication over converters (like modem or optical converters) to other devices does not work. The S-Bus communication works fine, if no converters are used in between. Also other communications protocols then S-Bus like "Mode C, Modbus" works fine on the PCD2.F2xx0 and PCD3.F2xx module (with and without converters in between). On the print screen below