The tool tracewin.exe is a small executable that records the communication between Saia PG5® and the S-Bus communicaiton driver. It is very useful in order to analyze the communication between Saia PG5® and the PCD's. Since it logs the information of the SCommDll, it may also be used for recording S-Bus traffic of the SBC OPC server or any other software using the SBC S-Bus driver.
In a S-Bus network, programmed with FUPLA, when a slave station is disconnected or powered off, the communication can be very slow.
If for example a Scada system communicate over S-Bus slave gateway port or S-Bus PGU port with a slave station via a master gateway port then after a programm download to the gateway PCD (or if the gateway PCD is restarted) the S-Bus slave gateway port or the S-Bus PGU port of the gateway SPS is blocked. In order to communicate again through this ports a system reboot (powerup) of the gateway SPS is needed. This problem could occur on all communication channels between the PC and the PCD (USB, serial, TCP)
If there is only one CPU in the project you are not able to asign a SASI S-BUS Master IP.
The Sasi S-Bus Master F-Box indicates a diagnostic error and is red. The data is transmitted but obviously not properly.
If you want to use the S-Bus OPC-Server and PG5 on the same PC then you have to make attention to use the correct version of the S-Bus OPC-Server which fit with the corresponding version of the scommdll.
Product Category Remote I/O PCD7.Lxxx S-Bus RIO L1xx: Digital input RIO [...] PCD7.L1xx S-Bus remote I/O's Documentation [...] later) firmware version the register 17 can be used to define a lamella running time after stop position, see FAQ 101415 . Be careful if you place a lot of L1xx or L3xx S-Bus input modules
Product Category Remote I/O PCD7.Lxxx S-Bus RIO L3xx: Analogue input RIO [...] PCD7.L3xx S-Bus remote I/O's Documentation These leaflets are more up to date than the manual and TI, please first refer to the leaflet. Good to know Be careful if you place a lot of L1xx or L3xx S-Bus input modules on
PCD7.L1xx S-Bus remote I/O's Documentation [...] later) firmware version the register 17 can be used to define a lamella running time after stop position, see FAQ 101415 . Be careful if you place a lot of L1xx or L3xx S-Bus input modules [...] -100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room
PCD7.L3xx S-Bus remote I/O's Documentation These leaflets are more up to date than the manual and TI, please first refer to the leaflet. Good to know Be careful if you place a lot of L1xx or L3xx S-Bus input modules on [...] -100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room