8.K100 (for PCD8.P100) and .K110 (for PC's) are obsolete and replaced by PCD8.K101 and .K111 respectively. The new cables support as well the S-Bus protocol and are required to program PCD1.Mxxx, PCD2.M150, PCD [...] be detected. In this case, the only possibility for going online in PGU mode is using the USB cable (or using an S-Bus PGU port which had been configured in the hardware settings previously [...] ! PCD7.D761 / D763 loses communication on Profi S-Bus! (FAQ #100477) On a Profi S-Bus network when PCD7.D76_ terminals
2? 29.01.2019 #102029 - Why can the PCD7.LRxx-P5 IRM room controller as S-Bus master, not read/write datas (inputs and outputs) from S-Bus slave devices via S-Bus [...] ? 16.11.2018 #102026 - Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used [...] ? 29.11.2017 #102008 - PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or
2? 29.01.2019 #102029 - Why can the PCD7.LRxx-P5 IRM room controller as S-Bus master, not read/write datas (inputs and outputs) from S-Bus slave devices via S-Bus [...] ? 16.11.2018 #102026 - Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used [...] ? 29.11.2017 #102008 - PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or
E-Line S-Serie combined input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC - 8 universal digital/analogue inputs - digital inputs 24 VDC - analoque inputs 12 bits 0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm - 1 interface RS-485 (S-Bus and Modbus) - 1 USB Service interface
On the PG5 device configuratior it’s possible to activate/deactivate the RS485/RS422 Bus termination of the port 3 (D-Sub #2 connector; RS485/RS422) of the PCD3.M5340.
With the web-panels mentioned below it's not possible to connect PCD's with S-Bus over RS485 to the web-panel and to display the web-pages stored on the PCD. The only possible connection type to display web-pages from PCD's is HTTPDirect (Ethernet connection). The following web-panels don't have an RS485 interface: - PCD7.D450WTPF - PCD7.D470WTPF - PCD7.D412DTPF The PCD7.D412DT5F has an integrated RS485 port. It's also possible to add a second serial port by means of a module PCD7.F1xxS but the serial ports can only be used from the PLC program, which is embedded in the device and not from
! PCD7.D761 / D763 loses communication on Profi S-Bus! (FAQ #100477) On a Profi S-Bus network when PCD7.D76_ terminals [...] ! How to convert variables from S-Bus to Ether S-Bus driver when changing terminal type? (FAQ #100461) It is possible to convert all the variable from a S-Bus driver to Ether S-Bus driver if an existing project has to be used on another terminal type (e.g. PCD7.D786 convert to PCD7.D786ET)! Hereby the procedure to
01 0271 0022 fexible cable Note: If the bautrates isn't greater than 187,5 bautes (for ex. Profi S-Bus with PCD3.M3xx / PCD7.D7xx) you can use other more advantegeous cable, especially [...] 38,4 kBaud On the port 1 it’s not possible to use the S-Bus party Master mode. Mode D is not supported. Profibus Supported baudrates Supported [...] and connector as the communication speed goes up to 12 Mbautes! Those cable and connectors are used in Profibus DP, FMS, Profis S-Bus, Profi S-IO and MPI! Wiring and Network
01 0271 0022 fexible cable Note: If the bautrates isn't greater than 187,5 bautes (for ex. Profi S-Bus with PCD3.M3xx / PCD7.D7xx) you can use other more advantegeous cable, especially [...] 38,4 kBaud On the port 1 it’s not possible to use the S-Bus party Master mode. Mode D is not supported. Profibus Supported baudrates Supported [...] and connector as the communication speed goes up to 12 Mbautes! Those cable and connectors are used in Profibus DP, FMS, Profis S-Bus, Profi S-IO and MPI! Wiring and Network
). However, it is important to know that only one S-Bus client can access the S-Web Server over Ether-S-Bus at the same time! Problem By desing the S-Web Server of a PCD can only be accessed by one S-Bus connection per physical port (Serial-S-Bus, Profi-S-Bus, Ether-S-Bus). As result it is possible to access the S-Web Server over Serial-S-Bus and in parallel over Ether-S-Bus, but it is [...] ) How many web-clients can be connected at the same time to the S-Web Server over Ether-S-Bus? (FAQ #101431) The first