three-phase energy meters with S-Bus, M-Bus or Modbus communication. Note also that the format of the serial number has changed for the S-Bus and Modbus (is now ASCII) and due of this it's necessary to [...] Comm. interface Prod.date =1322 S-Bus Register 13 12, 13 Modbus Register 16, 17 16, 17, 18 M-Bus Byte 8, 9, 10, 11 8, 9, 10, 11 [...] . Why is it not possible to communicate over S-Bus with the S-Energy meter (ALD1/ALE3/AWD3)? (FAQ #101591) Due to a
Product Category Programmable controller PLC Accessories SO to S-Bus Interface PCD7.H104S [...] PCD7.H104xx S0 converter Documentation Software / Drivers The Fupla libraries installed by default in PG5 1.4.300 and later include the FBoxes for the PCD7.H104S
. PCD1 / E-Line Why the RS-485 S-Bus communication [...] the some of the S-Bus telegrams transferred from the PCD S-Bus master to the S-Bus slaves over RS485 are malformed, and the S-Bus slave does reject the request from the master. This could lead to the situation that for example the PCD S-Bus master don’t receive actual values from E-Line RIO’s or that the program download of a PCD program from the PC to a Slave PCD which is located behind a
over serial PGU or S-Bus to the PCD, error message ‘Error 99: Can’t open port comx’ is shown in the PG5 debugger? (FAQ #101977) We have received the information that on an application it was not possible to access with PG5 version 2.1.420 over serial line (RS232) in PGU or S-Bus mode to the PCD and the message: Error 99: Can [...] : Why the S-Bus communication over TCP/IP between PCD’s doesn’t work anymore? (FAQ #101679) If the S-Bus communication
The Ether-S-Bus plugin allows filtering the captured telegrams based on one or several properties of the telegram such as the command code contained in the telegram and/or the value of a transmitted media etc.
When a PCD7.D7xx display visualizes the resources from several PCD stations (more than 3) over Ether S-Bus, some stations don't respond or respond with the ressources from other stations!
accessed using serial links (Serial-S-Bus), Profibus (Profi-S-Bus) or Ethernet TCP/IP Networks (Ether-S-Bus) and allows to display predefined and user-defined web pages. Web Editor to create interactive pages easily (in preparation), Web.Builder software to convert the user defined webpages in a format that can be stored in the PCD's, Web-Connect software running on a PC to convert the S-Bus [...] Services Getting started Introduction Product selection guide per topic SBC S
The E-Line App does allow to configure the communication protocol on the RS485 of the E-Line RIO’s (S-Bus or Modbus) the baudrate and the parity and stop bit as the station number of the E-Line RIO device. The E-Line App does run on PC’s with Windows 7, Windows 10 and Windows 11 (32/64 - Bit) operation systems. USB connection to the PCD1 E-Line RIO’s is required.
. Why does my RS-232 S-Bus communication not work with the PCD2.F2xx0 and PCD3.F2xx module? (FAQ #101775) The RS-232 S-Bus [...] V020) it may be, that the S-Bus communication over converters (like modem or optical converters) to other devices does not work. The S-Bus communication works fine, if no converters are used in between. Also other communications protocols then S-Bus like "Mode C, Modbus" works fine on the PCD2.F2xx0 and PCD3.F2xx module (with and without converters in between). On the print screen below
. Why does my RS-232 S-Bus communication not work with the PCD2.F2xx0 and PCD3.F2xx module? (FAQ #101775) The RS-232 S-Bus [...] V020) it may be, that the S-Bus communication over converters (like modem or optical converters) to other devices does not work. The S-Bus communication works fine, if no converters are used in between. Also other communications protocols then S-Bus like "Mode C, Modbus" works fine on the PCD2.F2xx0 and PCD3.F2xx module (with and without converters in between). On the print screen below