corrections All PCD’s: On S-Bus data mode, if S-Bus CRC contains a S-Bus DLE as last character then S-Bus telegram is incorrect and not accepted from S-Bus recipient. (Since FW 1.28.20) All PCD’s: Not [...] implemented correctly. All PCD’s: When S-Bus IP Nodelist is used it’s possible that the communication using nodes does no more work after execute a download in run All PCD’s: XOB parameter as Registers [...] Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026)
1.M2110R1. Smart Rio Manager and Profibus RIO functions are not supported! Limitation of remote RIO's (a maximum of 10 S-Bus and 10 Modbus station units is allowed per PCD1.M2110R1). On the slot 1, a [...] . PCD1 / _Firmware Classic Why the RS-485 S-Bus [...] possible that the some of the S-Bus telegrams transferred from the PCD S-Bus master to the S-Bus slaves over RS485 are malformed, and the S-Bus slave does reject the request from the master. This could
corrections All PCD’s: On S-Bus data mode, if S-Bus CRC contains a S-Bus DLE as last character then S-Bus telegram is incorrect and not accepted from S-Bus recipient. (Since FW 1.28.20) All PCD’s: Not [...] implemented correctly. All PCD’s: When S-Bus IP Nodelist is used it’s possible that the communication using nodes does no more work after execute a download in run All PCD’s: XOB parameter as Registers [...] Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026)
: Set the Triac Output 0 to PWM . PWM Time Triac0 should be set between 30s - 600s. In this example it is set to 40s . It is the time for one PWM cycle. Download the [...] the Battery increased short the time duration. Summary of working principle with the Lithium Battery System with passive battery supervision applied on the following PCD’s: PCD [...] 2001 applied on the following PCD’s: PCD1.M2xxx, PCD2.M170, PCD2.M480, PCD2.M5xxx, and PCD3.Mxxxx If the 24VDC power is switched on, then the voltage of the battery is measured during short time all
). However, it is important to know that only one S-Bus client can access the S-Web Server over Ether-S-Bus at the same time! Problem By desing the S-Web Server of a PCD can only be accessed by one S-Bus connection per physical port (Serial-S-Bus, Profi-S-Bus, Ether-S-Bus). As result it is possible to access the S-Web Server over Serial-S-Bus and in parallel over Ether-S-Bus, but it is [...] . PCD1 / _Firmware Classic Why the RS-485 S-Bus
). However, it is important to know that only one S-Bus client can access the S-Web Server over Ether-S-Bus at the same time! Problem By desing the S-Web Server of a PCD can only be accessed by one S-Bus connection per physical port (Serial-S-Bus, Profi-S-Bus, Ether-S-Bus). As result it is possible to access the S-Web Server over Serial-S-Bus and in parallel over Ether-S-Bus, but it is [...] . PCD1 / _Firmware Classic Why the RS-485 S-Bus
). However, it is important to know that only one S-Bus client can access the S-Web Server over Ether-S-Bus at the same time! Problem By desing the S-Web Server of a PCD can only be accessed by one S-Bus connection per physical port (Serial-S-Bus, Profi-S-Bus, Ether-S-Bus). As result it is possible to access the S-Web Server over Serial-S-Bus and in parallel over Ether-S-Bus, but it is [...] . PCD1 / _Firmware Classic Why the RS-485 S-Bus
). However, it is important to know that only one S-Bus client can access the S-Web Server over Ether-S-Bus at the same time! Problem By desing the S-Web Server of a PCD can only be accessed by one S-Bus connection per physical port (Serial-S-Bus, Profi-S-Bus, Ether-S-Bus). As result it is possible to access the S-Web Server over Serial-S-Bus and in parallel over Ether-S-Bus, but it is [...] . PCD1 / _Firmware Classic Why the RS-485 S-Bus
). However, it is important to know that only one S-Bus client can access the S-Web Server over Ether-S-Bus at the same time! Problem By desing the S-Web Server of a PCD can only be accessed by one S-Bus connection per physical port (Serial-S-Bus, Profi-S-Bus, Ether-S-Bus). As result it is possible to access the S-Web Server over Serial-S-Bus and in parallel over Ether-S-Bus, but it is [...] . PCD1 / _Firmware Classic Why the RS-485 S-Bus
the electrical systems (Saia PCD1.M0160E0) is a Function PCD that can be used immediately in the default setting without any programming. Energy meters connected via S-Bus and H104SE gateway modules for [...] PCD1 / _Firmware Classic Why the RS-485 S-Bus [...] possible that the some of the S-Bus telegrams transferred from the PCD S-Bus master to the S-Bus slaves over RS485 are malformed, and the S-Bus slave does reject the request from the master. This could