Combinable room control system with serial S-Bus interface for fan-coil and air quality control applications Room controller 230 VAC with: - 2 triac outputs, - 2 outputs 0…10 V, - 1 relay for electrical heating, - 3-stage or variable fan speed control, - with additional air quality control - and light & sunblind functionality
Combinable room control system with serial S-Bus interface for fan-coil and air quality control applications Room controller 24 VAC with: - 2 triac outputs, - 2 outputs 0…10 V, - 1 relay for electrical heating, - 3-stage (230 VAC) - or variable fan speed control, - with additional air quality control - and light & sunblind functionality
Combinable room control system with serial S-Bus interface for fan-coil and air quality control applications Double room controller 230 VAC for radiator/cooling ceiling combinations and VAV applications with: - 4 triac outputs, - 2 outputs 0…10 V, - 2 relays for electrical heating and autonomous interfaces for digital room control units
If the PG5 (or the S-Bus driver SCommDdll) is already running and one doubleclicks a PG5 program file (such as *.src or *.fup), it is possible that the file is not opened but a window named SCommCom with the message "Try to load another SCommCom.dll..." is shown.
A PCD7.D7xx Terminal can access several PCD's in an S-Bus network, it is as well possible to have one gateway station in the network and access PCD's that are located in a subnet. The response timeout has to be adapted accordingly.
If the SBC S-Bus OPC server was launched by a request of an OPC client located on another machine, the SCommDll (or SCommDrv) is not available for the user working on the PC where the OPC server is running.
The modem doesn't send any SMS and Modem 14 Fbox indicates: NO Modem In order to be on line on a PCS1 with a modem, it is necessary to assigne another port (for example Port 1 + RS 232) as S-Bus PGU port.
HONEYWELL S0 pulse counter with Modbus interface Main features - Up to 99 S0-Modbus Modules on the same bus - 4 S0 pulse inputs (S01+... S04+) per S0-Modbus Module - Up to 396 S0 devices on the same Modbus - The inputs comply with the S0 standard 62053-31 - Integrated RS-485 termination resistor - LED for bus activity indication
protected, hidden or that the creation date of the files has been newer than the one contained in the patch. Solution In order to solve this issue, please install the S-Bus Communication library 2.6.150 or later (this will install the library again including all the files in the language dependant sub folders). The S-Bus communication library can be downloaded from the support page in the section [...] Guidelines for programming S-Bus communication (FAQ #100537) In order to achieve a high and constant data throughput with S-Bus
protected, hidden or that the creation date of the files has been newer than the one contained in the patch. Solution In order to solve this issue, please install the S-Bus Communication library 2.6.150 or later (this will install the library again including all the files in the language dependant sub folders). The S-Bus communication library can be downloaded from the support page in the section [...] Guidelines for programming S-Bus communication (FAQ #100537) In order to achieve a high and constant data throughput with S-Bus