PCD1.M2120, PCD2.M5540 and all PCD3.Mxxxx with Ethernet connection. In PG5 1.4.301.15 the field MAC address remains empty. There is another way to get the MAC address of a PCD with Ethernet connection. Open the Online Debugger and enter D for Display and S for CPU-Status. This works for PCD1.M2120, PCD2.M5540 and all PCD3.Mxxxx with Ethernet connection Remark: There is a more [...] program with PG5 2.0.200 to a PCD1.M2xx0 or PCD3.Mxx60 the error message "Command not accepted: NAK response" can be returned by the downloader. Symptom When downloading a big program with PG
connected to PCD3.Mxxx or PCD2.M480 PLC's over Profi S-Bus, the terminal loses the communication after some time and get even frozen. This problem is corrected in the new boot, FW and driver. The PCD8.D81 V 5.09 is needed , the attached files have to be copied in it (see procedure below). It is also necessary to update the PCD3.Mxxx and PCD2.M480 FW with the version PCD3.Mxxx_023.blk / PCD2.M480_$27 or [...] 01 0271 0022 fexible cable Note: If the bautrates isn't greater than 187,5 bautes (for ex. Profi S-Bus with PCD3.M3xx / PCD7.D7xx) you can use other more advantegeous cable, especially
connected to PCD3.Mxxx or PCD2.M480 PLC's over Profi S-Bus, the terminal loses the communication after some time and get even frozen. This problem is corrected in the new boot, FW and driver. The PCD8.D81 V 5.09 is needed , the attached files have to be copied in it (see procedure below). It is also necessary to update the PCD3.Mxxx and PCD2.M480 FW with the version PCD3.Mxxx_023.blk / PCD2.M480_$27 or [...] 01 0271 0022 fexible cable Note: If the bautrates isn't greater than 187,5 bautes (for ex. Profi S-Bus with PCD3.M3xx / PCD7.D7xx) you can use other more advantegeous cable, especially
connected to PCD3.Mxxx or PCD2.M480 PLC's over Profi S-Bus, the terminal loses the communication after some time and get even frozen. This problem is corrected in the new boot, FW and driver. The PCD8.D81 V 5.09 is needed , the attached files have to be copied in it (see procedure below). It is also necessary to update the PCD3.Mxxx and PCD2.M480 FW with the version PCD3.Mxxx_023.blk / PCD2.M480_$27 or [...] 01 0271 0022 fexible cable Note: If the bautrates isn't greater than 187,5 bautes (for ex. Profi S-Bus with PCD3.M3xx / PCD7.D7xx) you can use other more advantegeous cable, especially
Or "What is the difference between 0-, $- and #-firmware versions?". PCD firmware for non-Saia PCD® COSinus Systems (PCD1, PCD2.M1x0, PCD4, PCD6 and PCS) are named with 3 letters (e.g. 010, B0W or #31). This FAQ explains the meaning of these version and how to figure out which one is more recent.
The IL instruction DSP (display value on PCD7.F530 display) is not supported on Saia PCD® COSinus systems. When downloading it to a Saia PCD® COSinus system, the PCD will not go in RUN and give an error message such as "Invalid instruction" (e.g. a PCD2.M480), "Precompiler error" or "Invalid OPCODE" (on a PCD3.M5xx0 with firmware 1.10.16).
can be used in I/O slots 0 to 3 of PCD2.M5 or I/O slot 0 or 1 on a PCD2.M4 or PCD1.M2 [...] Product Category Programmable controller PCD3: CPUs, cassette design Fxxx: Comm modules F2xx: for I/O slot 0..3 F281: MP Bus [...] PCD2.F2xxx Serial communication modules to be placed in I/O slots 0..3
4x60. PCD2 / M4x60 Why on a PCD3.M5/6xxx or a PCD2.M [...] module and the changes made by the FBox 'PCD3.BAT0' are stored in the battery module and not in the PCD3.M5/6, PCD2.M45xx. As all information concerning the overvoltage limit check are stored in the [...] COSinus FW 1.28.37 was released as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1
4x60. PCD2 / M4x60 Why on a PCD3.M5/6xxx or a PCD2.M [...] module and the changes made by the FBox 'PCD3.BAT0' are stored in the battery module and not in the PCD3.M5/6, PCD2.M45xx. As all information concerning the overvoltage limit check are stored in the [...] COSinus FW 1.28.37 was released as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1
On older PCD’s it was possible to set the PCD3.Mxx6x in to the firmware download mode by switching the run/stop switch (below the M1 memory slot) quickly several times during the start-up of the PCD. On newer PCD’s it’s no more possible to set the PCD in the firmware download mode with this procedure.