work on port 2 on PCD3.M3x60 & PCD3.M5360. PCD3.M6860: Ping request from over rooter from different sub net is not respond. PCD3.M6860/M880: Profibus/S-IO/Profi-SBus does not work stable. PCD3.M [...] 2220-C15 Support of PCD2.M4x60 Support of PCD3.M3160/PCD3.M3360/PCD3.M5360 Support of PCD3.M6880, PCD3.T668 Standby-CPU-System Improvements PCD2.M4x6x, support Interrupt when reaching the [...] the firmware. Please update to version 0F1. Please note that PCD7.R400 modules delivered after April 2010 require the PCD2.M170 firmware version 0F0 or later. PCD3 LIO and PCD2.M17x: to use
work on port 2 on PCD3.M3x60 & PCD3.M5360. PCD3.M6860: Ping request from over rooter from different sub net is not respond. PCD3.M6860/M880: Profibus/S-IO/Profi-SBus does not work stable. PCD3.M [...] 2220-C15 Support of PCD2.M4x60 Support of PCD3.M3160/PCD3.M3360/PCD3.M5360 Support of PCD3.M6880, PCD3.T668 Standby-CPU-System Improvements PCD2.M4x6x, support Interrupt when reaching the [...] COSinus FW 1.28.37 was released as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1
work on port 2 on PCD3.M3x60 & PCD3.M5360. PCD3.M6860: Ping request from over rooter from different sub net is not respond. PCD3.M6860/M880: Profibus/S-IO/Profi-SBus does not work stable. PCD3.M [...] 2220-C15 Support of PCD2.M4x60 Support of PCD3.M3160/PCD3.M3360/PCD3.M5360 Support of PCD3.M6880, PCD3.T668 Standby-CPU-System Improvements PCD2.M4x6x, support Interrupt when reaching the [...] as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1.28.16 was introduced into
PCD3 Overview PCD3.M PCD3 Plus (fast CPU) Overview PCD3.M Compact and extendable PCD3 Compact Overview PCD3.M
Yes, a new set of instructions for calculation with IEEE floating point values (single and double) has been added to the firmware of PCD2.M480, PCD2.M5xx0 and PCD3.
Yes, this is possible with firmware version 1.10.15 and later.
Up to firmware version 1.14.23 the maximal amount of COBs (Cyclic Organization Blocks) has been 16. In firmware 1.14.23 the amoung of COBs has been increased to 32. Thus on PCD2.M5 and PCD3 and newer systems up to 32 COBs can be used (COB to 31).
For "reading" a value from a PCD text (e.g. copying "1234" from a PCD text with content "The next number is: 1234" into a Register) a new System Function has been added for PCD3 and PCD2.M5xx0.
In the system catalogue there is a schematic of a PCD connected to a BACnet/IP network which could lead to a missinterpretation. Although BACnet is supported by a PCD3 or a PCD2.M5xx0 and LON on IP will be suppored in future, it won't be possible to run both stacks on the same PCD at the same time.
No. This is a PG5 restriction. The ethernet configuration can only be loaded to CPU 0. It is not possible to configure the PCD6.M3 with ethernet-module as an other CPU than CPU 0.