Modbus are automatically installed with PG5 2.0 but need to be licensed. For older PCD systems (such as the PCD2.M170 or the PCD1.M1x5) a pure FBox solution from the company Engiby exists [...] over Ethernet between a Saia PCD and a Siemens S7-314C-2 does not work correctly? (FAQ #101973) Situation: The PCD [...] Modbus on Saia PCD® Introduction Modbus is communications protocol based on a master/slave or client
applications created with the Saia PG5® Web Editor5/Web Editor8 and stored on a Saia PCD® Device. The web-/IT interfaces are integrated in the basic system of all Saia PCD® controllers The integrated station [...] . In addition, also third party applications (via internal container) can be started from the MB app. If a URL Jump is made to a page which does not contain PCD Web-application (e.g. PDF document), a [...] 138.2: Modifications: - PCD Symbols containing offsets doesn’t work - FileViewer doesn’t work - Trouble when SBC MB App is used on PC’s with two screens
applications created with the Saia PG5® Web Editor5/Web Editor8 and stored on a Saia PCD® Device. The web-/IT interfaces are integrated in the basic system of all Saia PCD® controllers The integrated station [...] . In addition, also third party applications (via internal container) can be started from the MB app. If a URL Jump is made to a page which does not contain PCD Web-application (e.g. PDF document), a [...] 138.2: Modifications: - PCD Symbols containing offsets doesn’t work - FileViewer doesn’t work - Trouble when SBC MB App is used on PC’s with two screens
A MPI-communication can be done over a serial RS 232 port of each PCD2.Mxx7
The PCD2.M480, PCD2.M5xxx and PCD3.M5xxx can be used as an MPI server (Profi-S-Net port). As the mentioned PCD's only reply to MPI requests, this functionality can be used to connect for instance an intelligent terminal that supports MPI (an OP for instance), but other MPI functions like global data exchange or event driven communication are not supported.
minimal system requirements are: PG5 2.0.200 PCD Firmware 1.16.48 Modules supporting a firmware update: PCD2.F26xx PCD2.F27xx PCD3.F26x PCD [...] minimal system requirements are: PG5 2.0.200 PCD Firmware 1.16.48 Modules supporting a firmware update: PCD2.F26xx PCD2.F27xx PCD3.F26x PCD [...] to a bus and simplify the cable work significantly for HeaVAC applications.With PCD2.F2810 (for PCD1.M2xx0 and PCD2.M5) and PCD3.F281 modules (for PCD3 systems) a PCD system can be connected to the MP
a version of PG5 2.0 more recent than 2.0.200 or copy the attached file "pcd3compactfamily.saiaxml" into the folder: c:\Program Files\SAIA-Burgess\PG5_20\DeviceTemplates\ and restart PG5 2 [...] Due to an error in the PG5 device template file of PG5 2.0.200 it’s not possible to switch on/off the relay outputs of the PCD3.WAC CPUs. (PCD3.M2230A4T5, PCD3.M2330A4T1, PCD3.M2330A4T3, PCD3.M2330A4T5) Problem Due to an error in the PG5 device template file of PG5 2.0.200 it isn't possible to switch on/off the relay outputs of the PCD3.WAC CPUs (PCD3.M2230A4T5, PCD3.M2330A4T1, PCD3.M2330A4T3, PCD3.M2330A
a version of PG5 2.0 more recent than 2.0.200 or copy the attached file "pcd3compactfamily.saiaxml" into the folder: c:\Program Files\SAIA-Burgess\PG5_20\DeviceTemplates\ and restart PG5 2 [...] Due to an error in the PG5 device template file of PG5 2.0.200 it’s not possible to switch on/off the relay outputs of the PCD3.WAC CPUs. (PCD3.M2230A4T5, PCD3.M2330A4T1, PCD3.M2330A4T3, PCD3.M2330A4T5) Problem Due to an error in the PG5 device template file of PG5 2.0.200 it isn't possible to switch on/off the relay outputs of the PCD3.WAC CPUs (PCD3.M2230A4T5, PCD3.M2330A4T1, PCD3.M2330A4T3, PCD3.M2330A
(since booter version 1.24.11) See FAQ 101948 The differences between firmware version 1.16.42 and 1.16.69 are listed in FAQ 101624 . For configuring a PCD3.Mxx60 PG5 2.0.200 (SP2 [...] a version of PG5 2.0 more recent than 2.0.200 or copy the attached file "pcd3compactfamily.saiaxml" into the folder: c:\Program Files\SAIA-Burgess\PG5_20\DeviceTemplates\ and restart PG5 2 [...] Due to an error in the PG5 device template file of PG5 2.0.200 it’s not possible to switch on/off the relay outputs of the PCD3.WAC CPUs. (PCD3.M2230A4T5, PCD3.M2330A4T1, PCD3.M2330A4T3, PCD3.M2330A