version 005 can be found on the PCD4.M1x0 pages. PCD4.M340 (obsolete): CPU0 has got the same firmware as a PCD4.M1x0, the latest version 005 can be found on the PCD4.M1x0 pages. CPU1 with LAN2 has the [...] (or in case a PC is used, by interpreting the tracewin files). This phenomenon can be observed on PCD1.M1x5, PCD2.M150, PCD2/4.M170 and PCS1 systems (with firmware which are supporting the "Secure S [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the
4.M340 (obsolete): CPU0 has got the same firmware as a PCD4.M1x0, the latest version 005 can be found on the PCD4.M1x0 pages. CPU1 with LAN2 has the same firmware as a PCD6.T1xx, last version 005, only available on [...] (or in case a PC is used, by interpreting the tracewin files). This phenomenon can be observed on PCD1.M1x5, PCD2.M150, PCD2/4.M170 and PCS1 systems (with firmware which are supporting the "Secure S [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the
correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively. [...] PCD3 / W6x5 Why do the output of the PCD2 [...] the W6x5 module is plugged in, it’s possible that the analog output signal supplied from the W6x5 is not stable and is oscillating. Symptom The outputs of the PCD2/3.W6x5 do not deliver stable
correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively. [...] PCD3 / W6x5 Why do the output of the PCD2 [...] the W6x5 module is plugged in, it’s possible that the analog output signal supplied from the W6x5 is not stable and is oscillating. Symptom The outputs of the PCD2/3.W6x5 do not deliver stable
correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively [...] value of the analogue outputs of the PCD2.W605/W615/W625 card, if the PCD2.W6x5 card is plugged in a PCD2.C1000 or PCD2.C2000 extension? (FAQ #102030) [...] analogue output value of the PCD2.W6x5 module with the application program, if the PCD2.W6x5 card is plugged in to a PCD2.C1000/C2000 extension Concerned products: PCD2.W6x5 cards
correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively [...] value of the analogue outputs of the PCD2.W605/W615/W625 card, if the PCD2.W6x5 card is plugged in a PCD2.C1000 or PCD2.C2000 extension? (FAQ #102030) [...] analogue output value of the PCD2.W6x5 module with the application program, if the PCD2.W6x5 card is plugged in to a PCD2.C1000/C2000 extension Concerned products: PCD2.W6x5 cards
MC5 mode on F2xxx module All PCD’s: RS485 driver keep holding bus after a while All PCD’s: Http request ‘is modified’ is not handled correctly on the PCD Web-Server which lead to the effect that [...] (CVE-2017-9628) All PCD's: The Modbus CSF CloseSRPort does not free the port then a open/SASI call give an error and the port does not work. PCD1.M2xx0 PCD1.M22x0 PCD2.M4x60: PCD can crash while power down [...] PG5 2.1 and 2.2 with E-Line S-Bus communication library < 1.2.110, why the S-Bus communication on the master PCD stops either after a certain time? (FAQ #102009)
PCD3 / Wxxx On a PCD2.M4560 or PCD3.W5560, why [...] If the PCD2/3.W220Z18 card is plugged in to a ‘Power PCD‘ and if all 8 analog inputs channels of the PCD2/3.W220Z18 module are connected to 8 PT100 sensors then the measured PT100 temperature values of [...] issue, use and connect only up to 7 PT100 sensors to the PCD2/3.W220Z18 or do use a PCD2/3.W350 module, if all 8 PT100 are needed. On the ‘old’ PCD’s like PCD2.M170 or PCD3.M5540 the PCD internal
PCD3 / Wxxx On a PCD2.M4560 or PCD3.W5560, why [...] If the PCD2/3.W220Z18 card is plugged in to a ‘Power PCD‘ and if all 8 analog inputs channels of the PCD2/3.W220Z18 module are connected to 8 PT100 sensors then the measured PT100 temperature values of [...] issue, use and connect only up to 7 PT100 sensors to the PCD2/3.W220Z18 or do use a PCD2/3.W350 module, if all 8 PT100 are needed. On the ‘old’ PCD’s like PCD2.M170 or PCD3.M5540 the PCD internal
inputs of a module PCD2/3.W525 could perturbate an other input of the same module Module PCD2/3.W525 are not designed as other analog input modules (as PCD2/3.W340 or W200 for example). Particularities [...] correctly. Solution This problem is solved with hardware version A or C and newer of the PCD2.W6x5 or PCD3.W6x5 respectively. What is the signification of the I/O words of a PCD2/3.W525 module? (FAQ #101552) When configuring a W525 module using