PCD1.G2000-A20
-
E-Line RIO 6DI/AI, 2DO, 2AO
-
E-Line combined input/output module
Manual priority operating level for all outputs
Status LED for input and outputs
Supply 24 VDC
6 universal digital/analogue inputs
- digital inputs 24 VDC
- analogue inputs 12 Bit for
- 0...10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
- 0...2500 Ohm, 0...7500 Ohm, 0...300 kOhm
2 analog outputs 10 bits, 0...10 V
2 Triac outputs 24 VAC/1A or 230 VAC/1A
1 interface RS-485 (S-Bus and Modbus)
Bridge connectors for power supply and communication to connect to next RIO module
-
PCD1.G2100-A10
-
E-Line RIO 8 DI/AI
-
E-Line input module
Status LED for inputs
Supply 24 VDC
8 universal digital/analogue inputs
- digital inputs 24 VDC
- analogue inputs 12 Bit for
- 0...10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
- 0...2500 Ohm, 0...300 kOhm
1 interface RS-485 (S-Bus and Modbus)
Bridge connectors for power supply and communication to connect to next RIO module
-
PCD1.G2200-A20
-
E-Line RIO 8DI/AI, 4AO
-
E-Line combined input/output module
Manual priority operating level for all outputs
Status LED for input and outputs
Supply 24 VDC
8 universal digital/analogue inputs
- digital inputs 24 VDC
- analogue inputs 12 Bit for
- 0...10 V, Pt/Ni 1000, Ni 1000 L&S, NTC,
- 0...2500 Ohm, 0...7500 Ohm, 0...300 kOhm
4 analog outputs 10 bits, 0...10 V
1 interface RS-485 (S-Bus and Modbus)
Bridge connectors for power supply and communication to connect to next RIO module
-
PCD1.G5000-A20
-
E-Line RIO 16DI, 8Rel, 8AI, 4AO
-
E-Line combined input/output module
Manual priority operating level for all outputs
Status LED for input and outputs
Supply 24 VDC
16 digital inputs 24 VDC (Source operating)
4 relay normally open 230 VAC / 30 VDC, 4 A (resistive load)
4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load)
8 analog inputs 12 bits, 0...10 V,
Pt/Ni 1000, NI1000 L&S, NTC,
0...2500 Ohm, 0...7500 Ohm, 0...300 kOhm
4 analog outputs 10 bits, 0...10 V (10 mA max.)
1 interface RS-485 for S-Bus and Modbus, Modbus support since FW 1.08.04
-
PCD1.G5010-A20
-
E-Line RIO 12DI, 4Rel, 12AI, 8AO
-
E-Line combined input/output module
Manual priority operating level for all outputs
Status LED for input and outputs
Supply 24 VDC
12 digital inputs 24 VDC (Source operating)
4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load)
12 analog inputs 12 bits, 0...10 V,
Pt/Ni 1000, NI1000 L&S, NTC,
0...2500 Ohm, 0...7500 Ohm, 0...300 kOhm
8 analog outputs 10 bits, 0...10 V (10 mA max.)
1 interface RS-485 for S-Bus and Modbus, Modbus support since FW 1.08.04
-
PCD1.G5020-A20
-
E-Line RIO 8DI, 4Rel, 16AI, 4AO
-
E-Line combined input/output module
Manual priority operating level for all outputs
Status LED for inputs and outputs
Supply 24 VDC
8 digital inputs 24 VDC (Source operating)
4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load)
16 analog inputs 12 bits, 0...10 V,
Pt/Ni 1000, NI1000 L&S, NTC,
0...2500 Ohm, 0...7500 Ohm, 0...300 kOhm
4 analog outputs 10 bits, 0...10 V (10 mA max.)
1 interface RS-485 for S-Bus and Modbus, Modbus support since FW 1.08.04
Documentation
System Catalogue : E-Line
Extract | 26-215_A0160 | System Catalogue : E-Line |
Remote E-Line IOs L-Series
Flyer | PP31-018 | Remote E-Line IOs L-Series |
Remote E-Line IOs S-Series
Flyer | PP31-055 | Remote E-Line IOs S-Series |
PCD1.G2000-A20 E-Line S-Series RIO 6UI, 2AO, 2TR
Datasheet | 31-150 | PCD1.G2000-A20 E-Line S-Series RIO 6UI, 2AO, 2TR |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG13 | 1.77 MB | Download | |||
FRA13 | 1.80 MB | Download | |||
GER13 | 1.78 MB | Download | |||
ITA13 | 1.78 MB | Download |
PCD1.G2100-A10 E-Line S-Sries RIO 8UI
Datasheet | PP31-154 | PCD1.G2100-A10 E-Line S-Sries RIO 8UI |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG03 | 1.87 MB | Download | |||
FRA03 | 1.90 MB | Download | |||
GER03 | 1.89 MB | Download | |||
ITA03 | 1.88 MB | Download |
PCD1.G2200-A20 E-Line S-Series RIO 8UI, 4AO
Datasheet | PP31-151 | PCD1.G2200-A20 E-Line S-Series RIO 8UI, 4AO |
The E-Line S-Series RIO modules are controlled via RS-485 from a S-Bus or Modbus master and enable decentralised automation using industrial quality components.
The data point mix is specifically designed for applications in the HVAC sector.
ENG11 | 1.58 MB | Download | |||
FRA11 | 1.61 MB | Download | |||
GER11 | 1.60 MB | Download | |||
ITA11 | 1.59 MB | Download |
PCD1.G5000-A20 L-Series RIO 16DI, 8Rel, 8AI, 4AO
Datasheet | 31-140 | PCD1.G5000-A20 L-Series RIO 16DI, 8Rel, 8AI, 4AO |
The E-Line RIO modules are controlled via RS-485 and enable decentralised automation using industrial quality components. The data point mix is specifically designed for applications in the HVAC sector.
ENG13 | 2.85 MB | Download | |||
FRA13 | 2.87 MB | Download | |||
GER13 | 2.88 MB | Download | |||
ITA13 | 2.86 MB | Download |
PCD1.G5010-A20 L-Series RIO 12DI, 4Rel, 12AI, 8AO
Datasheet | 31-141 | PCD1.G5010-A20 L-Series RIO 12DI, 4Rel, 12AI, 8AO |
The E-Line RIO modules are controlled via RS-485 and enable decentralised automation using industrial quality components. The data point mix is specifically designed for applications in the HVAC sector.
ENG11 | 2.03 MB | Download | |||
FRA11 | 2.06 MB | Download | |||
GER11 | 2.06 MB | Download | |||
ITA11 | 2.04 MB | Download |
PCD1.G5020-A20 L-Series RIO 8DI, 4Rel, 16AI, 4AO
Datasheet | 31-142 | PCD1.G5020-A20 L-Series RIO 8DI, 4Rel, 16AI, 4AO |
The E-Line RIO modules are controlled via RS-485 and enable decentralised automation using industrial quality components. The data point mix is specifically designed for applications in the HVAC sector.
ENG12 | 1.87 MB | Download | |||
FRA12 | 1.88 MB | Download | |||
GER12 | 1.90 MB | Download | |||
ITA12 | 1.87 MB | Download |
Template for labels for the E-Line RIO coverset
Presentation | E-Line RIO coverset | Template for labels for the E-Line RIO coverset |
.pptx | 0.40 MB | Download |
Pictures - PCD1.G2000-A20
Info | 800 × 800 pixel | Pictures - PCD1.G2000-A20 |
Pictures - PCD1.G2100-A10
Info | 800 × 800 pixel | Pictures - PCD1.G2100-A10 |
Pictures - PCD1.G2200-A20
Info | 800 × 800 pixel | Pictures - PCD1.G2200-A20 |
Pictures - PCD1.G5000-A20
Info | 800 × 800 pixel | Pictures - PCD1.G5000-A20 |
Pictures - PCD1.G5010-A20
Info | 800 × 800 pixel | Pictures - PCD1.G5010-A20 |
Pictures - PCD1.G5020-A20
Info | 800 × 800 pixel | Pictures - PCD1.G5020-A20 |
Pictures - PCD1.K0206-005
Info | 800 × 800 pixel | Pictures - PCD1.K0206-005 |
Pictures - PCD1.K0206-025
Info | 800 × 800 pixel | Pictures - PCD1.K0206-025 |
Pictures - bridge connector
Info | 800 × 800 pixel | Pictures - bridge connector |
Web-templates for Web-Editor8
Web-8 Templates for E-Line RIO Modules
Software | Web-8 Templates for E-Line RIO Modules |
Web-Editor 8 templates for PG5 2.1 for the following modules:
- PCD1.B1000
- PCD1.B1010
- PCD1.B1020
- PCD1.G5000
- PCD1.G5010
- PCD1.G5020
To import the files in to the Web-Editor8, do open the Web-Editor8 and do click with the right mouse key to the "Librarires" window of the the Web-Edior8 and select the point "Import" and browse to the location where you have stored the zip files.
After the import the templates are available in the menu "E-Line, RIO"
1.0.17 | .zip | 0.14 MB | Download |
E-Line configuration App
The E-Line App does allow to configure the communication protocol on the RS485 of the E-Line RIO’s (S-Bus or Modbus) the baudrate and the parity and stop bit as the station number of the E-Line RIO device.
The E-Line App does run on PC’s with Windows 7 and Windows 10 operation systems.
USB connection to the PCD1 E-Line RIO’s is required.
E-Line RIO configuration App
Software | PG5 2.3.195 | E-Line RIO configuration App |
The E-Line App does allow to configure the communication protocol on the RS485 of the E-Line RIO’s (S-Bus or Modbus) the baudrate and the parity and stop bit as the station number of the E-Line RIO device.
The E-Line App does run on PC’s with Windows 7, Windows 10 and Windows 11 (32/64 - Bit) operation systems.
USB connection to the PCD1 E-Line RIO’s is required.
PG5 2.3.195 | .zip | 24.44 MB | Download |
FBox Library for communication with the E-Line devices
- ELine V1.3.120.saiazipThis version is required, if the following newer devices are used: PCD1.B1100-A20, PCD1.B1120-A20, PCD1.G2000-A20, PCD1.G2100-A20, PCD1.G2200-A20. The basic version V1.3.100 is provided on the updatemanager.
Minimal Firmware configuration
The minimum Firmware for the head station is 1.24.25
PCD1 E-Line firmware used in production
Firmware used in production PCD1.E-Line programmable modules and RIO I/O modules
Firmware Package | 1.04.24/1.08.06/1.08.13 | Firmware used in production PCD1.E-Line programmable modules and RIO I/O modules |
This firmware is used in the PCD production and the PCD1 E-Line programmable modules and RIO I/O modules L-Series and S-Seires are shipped with this firmware.
The programmable I/O modules:
FW 1.04.24
PCD1.G1100-C15
PCD1.G360x-C15
PCD1.F2611-C15
PCD1.W5300-C15
The RIO modules L-Series:
FW 1.08.06
PCD1.B1000-A20
PCD1.B1010-A20
PCD1.B1020-A20
PCD1.G5000-A20
PCD1.G5010-A20
PCD1.G5020-A20
The RIO modules S-Series:
FW 1.08.13
PCD1.A1000-A20
PCD1.A2000-A20
PCD1.B5000-A20
PCD1.B5010-A20
PCD1.E1000-A20
PCD1.G2000-A20
PCD1.G2100-A20
PCD1.G2200-A20
PCD1.W5200-A20
1.04.24/1.08.06/1.08.13 | .zip | 0.57 MB | Download |
Good to know
The differences between firmware version 1.04.07 and 1.08.06 are listed in FAQ 101990
Good to know
PG5 2.1.410 or later is to be used for working with the PCD1 E-Line
PCD1 / E-Line
- How to copy csv-Files and Webeditorproject files which are stored on the Intflash of a PCD, if you are replacing an internal micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102069)
- What is stored on the micro-SD memory card which is used on the circuit board of the PCD? (FAQ #102068)
- New firmware 1.08.16 for PCD1 E-Line Rio's (FAQ #102061)
- Is it possible to know the firmware version of the Top Print of the PCD1 E-Line RIOs? (FAQ #102059)
- What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102058)
- Why the RS-485 S-Bus communication between the PCD master and the slave does fail sometime, if FW 1.28.20…1.28.33 is used? (FAQ #102026)
- What are the differences between the COSinus firmwares FW 1.28.11 and FW 1.28.51? (FAQ #102010)
- PG5 2.1 and 2.2 with E-Line S-Bus communication library < 1.2.110, why the S-Bus communication on the master PCD stops either after a certain time? (FAQ #102009)
- PG5 2.1 and PG5 2.2 with S-Bus communication library 2.7.370, why the S-Bus communication on the master PCD stops either after a certain time or after the download of the program? (FAQ #102008)
- No Refresh from State of I/O's from E-Line Rio- Moduls after Fbox Update (FAQ #102001)
- What is the meaning of E-Line RIO – Leds & status specifications (FAQ #101998)
- What are the differences between E-Line firmwares FW 1.04.07 and 1.08.06? (FAQ #101990)