Saia PCD® Energy Meters
Energy meters are available in two compact and robust industrial designs (single phase and 3-phase meters). These two designs are the base for a wide product range.
CC Control Components
- What are the maximum energy consumption values for Energy meters and Energy Managers/ E-controllers? (FAQ #101899)
- Label and schema of PCD7.T162 are incorrect on housings produced before week 22 of 2011 (FAQ #101615)
- How to configure the S-Bus address on a ALE3? (FAQ #101476)
- What are the replacement possibilities for the CXE312 and CXE322? (FAQ #101462)
- Which energy meter of the ALE3 line do have pushbuttons? (FAQ #101387)
- CXG 201: Why is the screen flashing? (FAQ #101160)
- Why can't I start the software "CXControl"? (FAQ #101150)
- CXD(counter/tachometer) operating instructions are not up to date! (FAQ #100921)
CC Control Components / AAE3 / ALE3 / AWD3
- Does the printed serial number on the energy meter match the one read through the communication interface? (FAQ #101835)
- What is new in the SBC M-Bus library 2.7.006? (FAQ #101604)
- Why is it not possible to communicate over S-Bus with the S-Energy meter (ALD1/ALE3/AWD3)? (FAQ #101591)
- Why does the FBox for the AWD3 display a wrong current in case a current transformer is used? (FAQ #101528)
- The cos phi values aren't correct on phase 2 and 3 on AWD3D5WS00CxA00 energy counter! (FAQ #101505)
- How to configure the S-Bus address on a ALE3? (FAQ #101476)
- Why is the "SASI S-Bus Master" FBox red when communicating with S-Energy Meters? (FAQ #101469)
- Why is the "current" format of the FBox for the AWD not identical for all phases? (FAQ #101443)
- Why is the partial counter of tariff 1 not correctly displayed in the FBox for ALE3 Energy meters? (FAQ #101432)
- AWD3/ALE3/ALD1 energy meter with serial interface (for example S-Bus): What happens if the direction of the current is inverted (from Lx output to Lx input)? (FAQ #101406)
- AWD3/ALE3/ALD1 energy counter with serial interface (for example S-Bus): Is it possible to know whether the reactive power is generated from capacitive or inductive load? (FAQ #101405)
- Which energy meter of the ALE3 line do have pushbuttons? (FAQ #101387)
- Manufacturers of current transformers which could be used with AWD3 and AWD1 energy meter (FAQ #101161)
- Can I change the physical variable displayed on a ALE3 or a AWD3? (FAQ #101146)
CC Control Components / AAD1 / AAE1 / ALD1
- Does the printed serial number on the energy meter match the one read through the communication interface? (FAQ #101835)
- How to test the precision of a single phase energy meter with communication as it does not have S0 nor LED output? (FAQ #101771)
- What is new in the SBC M-Bus library 2.7.006? (FAQ #101604)
- Why is it not possible to communicate over S-Bus with the S-Energy meter (ALD1/ALE3/AWD3)? (FAQ #101591)
- AWD3/ALE3/ALD1 energy meter with serial interface (for example S-Bus): What happens if the direction of the current is inverted (from Lx output to Lx input)? (FAQ #101406)
- AWD3/ALE3/ALD1 energy counter with serial interface (for example S-Bus): Is it possible to know whether the reactive power is generated from capacitive or inductive load? (FAQ #101405)