PCD7.L60x-1
-
Serial-S-Net room controller with air quality control as well as light & blind functions
-
Documentation
System Catalogue : Dedicated Room Controllers
Extract | 26-215_A0330 | System Catalogue : Dedicated Room Controllers |
PCD7.T161 & PCD7.T162 - Terminator-Box
Datasheet | PP26-538 | PCD7.T161 & PCD7.T162 - Terminator-Box |
PCD7.L60x-1 room controller up to FW SV2.12
Manual | 27-608 | PCD7.L60x-1 room controller up to FW SV2.12 |
PCD7.L60x-1 Room controller from FW SV2.13
Manual | 27-628 | PCD7.L60x-1 Room controller from FW SV2.13 |
Replacement procedure of PCD7.L60x with PCD7.L60x-1
Tutorial | 26-019 | Replacement procedure of PCD7.L60x with PCD7.L60x-1 |
PCD7.L6xx room operation device
Manual | 26-859 | PCD7.L6xx room operation device |
PCD7.L645B/W Touch screen room operator unit
Manual | 27-605 | PCD7.L645B/W Touch screen room operator unit |
Software
FBox library for Room Controller PCD7.L60x-1 (supporting from firmware SV2.11) PG5 2.0/2.1/2.2
Software | FBox library for Room Controller PCD7.L60x-1 (supporting from firmware SV2.11) PG5 2.0/2.1/2.2 |
New FBoxes for "variable fan speed" function, which can only be used with PCD7.L60x-1 controllers from FW SV3.00.
Corrections/modifications:
Since V2.6.810:
- Minimum value for max. Fan limited to step 1 in 'Fan Configuration' and 'Fan Room 3', that no problem with deactivation of the cooling or heating output can be created anymore. (If fan max speed will be set to 0, then a safety function will be activated and the heating output will be deactivated)
- Bugfix for M/S-Mode in 'HVC Room' FBox
-------------------------------------------------
2.6.810 | .saiazip | 0.28 MB | Download |
FBox library for Room Controller PCD7.L60x-1 (supporting up to firmware SV2.12) PG5 1.4.300
Software | FBox library for Room Controller PCD7.L60x-1 (supporting up to firmware SV2.12) PG5 1.4.300 |
2.6.511 | .exe | 4.32 MB | Download |
Getting Started for Room Controller PCD7.L60x-1 with S-Web Demoproject for PG5 2.1
Software | Getting Started for Room Controller PCD7.L60x-1 with S-Web Demoproject for PG5 2.1 |
EN04 | .zip | 4.49 MB | Download |
Good to know
Procedure description for device replacement: PCD7.L60x with PCD7.L60x-1 room controller
Flyer | Procedure description for device replacement: PCD7.L60x with PCD7.L60x-1 room controller |
Connector information for PCD7.L62x light & sunblind extension modules
Flyer | Connector information for PCD7.L62x light & sunblind extension modules |
EN | 0.07 MB | Download |
Connector information for PCD7L62xN light & sunblind extension modules
Tutorial | 26-035 | Connector information for PCD7L62xN light & sunblind extension modules |
ENG03 | 0.48 MB | Download |
Variable fan speed function (from FW Version SV3.00)
Light & sunblind functions in combination with extension module PCD7.L62xN (from FW Version SV2.13)
Tutorial | Light & sunblind functions in combination with extension module PCD7.L62xN (from FW Version SV2.13) |
0.90 MB | Download |
The FBox library version 2.6.200 for the PCD7.L60x can be "grouped by function" in the FBox selector window of PG5 2.0.200.
The PCD7.L643 has been replaced by the PCD7.L644 in 2010 (repair service until end of 2015).
PCD7 / Lxxx
- It’s possible to connect a PT1000 temperature sensor to a PCD7.L60x room controller? (FAQ #101955)
- It’s possible to force the fan speed of the room controller PCD7.L60x-1 from the application program? (FAQ #101927)
- It’s possible to set the triac output Y1/Y2 of the PCD7.L60x-1 Room controller as 2 point output? (FAQ #101926)
- What is the accuracy of the temperature sensor which is integrated in the PCD7.L64x? (FAQ #101889)
- PCD7.L60x / PCD7.60x-1 Room controller; cooling or heating outputs Y1..Y4 are set to 0 if the fan is switched off. (FAQ #101861)
- Why on the PCD7.L644 display the set point correction shows 0.5°K steps even as 0.4°K steps has been configured? (FAQ #101838)
- Which inputs values needs the FBox 'Man AO' (L60x-1 Man AO) to control the Y3/Y4/PWMs outputs on a PCD7.L60x-1 controller? (FAQ #101837)
- Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812)
- PCD7.L6xx / PCD7.L79xN when working as Master/Slave with the application "2-pipe,CO" the change-over value of the Slave Room-Fbox is not transferred to the L6xx / L79xN . So the cooling output is not working. (FAQ #101791)
- Warum wird im Master/Slave Betrieben von PCD7.L6xx Raumreglern in der Applikation "2-Rohr Change-over" der change-over Wert der Slave Room-Fbox nicht auf den Regler geschrieben, so dass der Slave den Kühlausgang nicht ansteuern kann? (FAQ #101790)
- Hardware compatibility restrictions to respect when using PCD7.L645 with PCD7.L60x and L61x (FAQ #101740)
- On my PCD7.L645W/B, why are only groups 3 and 4 controlled when I selected all the 4 groups? (FAQ #101739)
- Why is the operation mode (OccMode) changing on a power down or configuration download to "1" (Reduced)? (FAQ #101683)
- How to use the "Dew point" on L60x and L79x room controllers? (FAQ #101657)
- How to link a remote control PCD7.L662 to the wireless receiver PCD7.L666? (FAQ #101635)
- Points to be considered when using the Room controllers L60x in "Stand alone Mode" (FAQ #101514)
- Why does the PCD7.L60x Room controller not work correctly in "Master/Slave" mode? (FAQ #101506)
- Why is the PCD7.L60x occupancy output switching from 1 to 0 when changing a setpoint value? (FAQ #101455)
- Can the PCD7.L12x rotate that lamellas back after the sun blinds moved down? (FAQ #101415)
- Can I use a Ni 1000 L&S sensor in the Device Configurator or with a PCD7.L310? (FAQ #101330)
- Which firmware version does my PCD7.L60x have? (FAQ #101298)
- Why is the output K 1/2 switched off in intervalls even if the commanded output signal is 100%? (FAQ #101265)
- Why can't I control the PCD7.L60x "Fan Speed" output in RIO mode? (FAQ #101264)
- Wrong AC supply wiring can destroy PCD7.L79x (FAQ #101241)
- PCD7.L611 LON support cooling with 0..10V output (FAQ #101233)
- New connecting terminal on the PCD7.L600, L601 and L603 room controller units (FAQ #101228)
- Wrong AC supply wiring can destroy PCD7.L602/3 (FAQ #101225)
- Can I control a Belimo 6-way valve with a PCD7.L6xx? (FAQ #101182)
- How many PCD7.L7xx room controllers can be connected to one PCD? (FAQ #101031)
- There is an error in the help of the PCD7_L60x FBox (FAQ #100984)
- Where from can I get connectors for PCD7.L62x light and sunblind extension modules? (FAQ #100967)
- Why are the internal symbols of the FBoxes for PCD7.L60x not created automatically? (FAQ #100960)
- Why is the heating output not high, even if the lower limit has been reached? The FBox status shows "Frost protection". (FAQ #100959)
- How can I read the production date of the PCD7.L1xx, L2xx, L3xx, L4xx, L5xx modules? (FAQ #100917)
- Problems when reading Input 5 to 8 of the PCD7.L100/L200 (FAQ #100887)
- How can I modify the function presence of a standalone PCD7.L60x modules? (FAQ #100883)
- How long does it take for a PCD7.L1xx or a PCD7.L3xx module to respond to an S-Bus telegram? (FAQ #100869)
- Where from to get FBoxes for the obsolete "RAG-Einzelraumregelung" (FAQ #100820)
- Why do the outputs on the PCD7.L120 RIO module not work? (FAQ #100722)
- Communication errors PCD7.L400 (FAQ #100667)
- Why do I have communication problems with the PCD7.L1xx, 2xx, 3xx, 4xx when using the "S-BUS Station" F-Box? (FAQ #100496)
- How can I get informations (Baud rate, Status...) from the DDC Rail and Save modules? (FAQ #100430)
- Roomcontroler PCD7.L72x (FAQ #100279)
- PCD7.L723 (FAQ #100230)
- PCD7.Lx00 doesn't respond anymore! (FAQ #100208)
- EMC compatibility (FAQ #100161)
- Bad communication on PCD7.Lxxx! (FAQ #100154)