saia-pcd.com
Communication et interaction
Entièrement modulaires
Compacts
modulaires
pWeb
Panel
PCD3
RIO PCD2
PCD1
PCD7
Points de données E/S
PCD3.M3120/M3160
PCD3.M3330/M3360
PCD3.M5340/M5360
PCD3.M5540/M5560
PCD3.M6560
PCD3.M6860/M6880
PCD3.T665
PCD3.T666/T668
PCD2.M4160
PCD2.M4560
PCD2.M5540
PCD1.M2120/M2160
PCD1.M0160E0
PCD1.M2110R1
PCD1.M2220-C15
PCD7.D457VT5F
PCD7.D410VT5F
PCD7.D412DT5F
Embarquée (points de données)
– – – – – – – – 4 4 – 18 18 24 7 – – –
Emplacements d’E/S embarqués
1)
4 4 4 4 4 4 4 4 4 4 8 2 – 1 2 – – –
Emplacements d’E/S en option via des modules d'extension
1)
– 60 60 60 60 60 3 3 – 60 56 – – – – – – –
Nombre maximal d'E/S
1)
64 10231023102310231023 256 256 64 10231023 50 18 40 50 – – –
Nombre maximal d'interfaces
(y compris PGU, USB, Ethernet)
11 11 13 13 13 12 2 11 6 10 15 8 4 6 8 4 4 4
Interfaces embarquées
RS-232, PGU à 115 kbps (Port 0)
– –
● ● ●
– – –
● ● ●
– – – – – – –
USB 1.1 Device, PGU
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Ethernet TCP/IP10/100 Mbits
Full-Duplex, détection/croisement automatique
1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1
Profi-S-Net jusqu'à 187.5 kbps ou
● ●
– –
● ●
–
●
– – –
● ● ● ● ● ● ●
Profi-S-Net jusqu'à 187.5 kbps
● ● ●
–
● ●
– – – – –
● ● ● ●
– – –
RS-422/485 jusqu'à 115 kbps (Port 3) ou
– –
●
– – – – – – – – – – – – – – –
RS-485 jusqu'à 115 kbps avec Isolation galvanique (Port 3) ou
– – –
●
– – – –
● ● ●
– – – – – – –
Esclave Profi-DP, Profi-S-Net jusqu'à 1.5 Mbps (Port 10)
– – –
●
– – – –
● ● ●
– – – – – – –
Maître Profibus DP jusqu’à 12 Mbps
– – – –
●
– – – – – – – – – – – – –
Interfaces en option
Emplacement C, maître DP 12 Mbps
– – – – – – – – –
● ●
– – – – – – –
BACnet® IP (avec modules PCDx.R56x)
2)
● ● ● ● ● ●
– –
● ● ● ● ● ● ● ● ● ●
BACnet® MS/TP
3)
(avec modules PCDx.R56x et modules PCDx.F215x)
● ● ● ● ● ●
– –
● ● ● ●
–
● ●
– – –
L
on
® (avec modules PCDx.R58x)
3)
● ● ● ● ● ●
– –
● ● ● ● ● ● ●
– – –
Modbus RTU série ou IP
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Emplacement pour PCD7.F1xxS (A1/A2)
– – – – – – – – 1 1 2 1 1 1 – 1 1 1
Emplacement d’E/S 0 pour PCD3.F1xx
RS-232 (RTS/CTS, DTR/DSR, CD, RI)
5)
PCD3.F121
● ● ● ● ● ●
–
●
– – – – – – – – – –
RS-485/RS-422 sans isolation galvanique
5)
PCD3.F110
● ● ● ● ● ●
–
●
– – – – – – – – – –
RS-485/RS-422 à isolation galvanique
6)
PCD3.F150
● ● ● ● ● ●
–
●
– – – – – – – – – –
Bus MP de Belimo
5)
PCD3.F180
● ● ● ● ● ●
–
●
– – – – – – – – – –
Emplacement d’E/S 0...à 3 pour PCD3
PCD3.F210 RS-485/422
5)
+ en opt. PCD7.F1xxS
4 4 4 4 4 4 – – – – – – – – – – – –
PCD3.F215 BACnet MS/TP...
5)
+ en opt. PCD7.F1xxS
)
4 4 4 4 4 4 – – – – – – – – – – – –
PCD3.F221 RS-232 full
5)
+ opt. PCD7.F1xxS
4 4 4 4 4 4 – – – – – – – – – – – –
PCD3.F240 L
on
FTT10
6)
+ opt. PCD7.F1xxS
4)
– – 4 4 4 4 – – – – – – – – – – – –
PCD3.F261 DALI y compris alimentation du bus
6)
4 4 4 4 4 4 – 4 – – – – – – – – – –
PCD3.F27x Maître M-Bus
5)
4 4 4 4 4 4 – 4 – – – – – – – – – –
PCD3.F281 Bus MP de Belimo
+ opt. PCD7.F1xxS
5)
4 4 4 4 4 4 – – – – – – – – – – – –
Emplacement E/A 0 à 3 pour PCD2 et
emplacement 0 à 1 pour PCD1 et
PCD2.F2100 RS-485/422
5)
+ en opt. PCD7.F1xxS
– – – – – – – – 4 4 4 2 – 1 2 – – –
PCD2.F2150 BACnet MS/TP...
5)
+ en opt. PCD7.F1xxS – – – – – – – – 4 4 4 2 – 1 2 – – –
PCD2.F2210 RS-232 full
5)
+ en opt. PCD7.F1xxS
– – – – – – – – 4 4 4 2 – 1 2 – – –
PCD2.F2400 L
on
FTT10
6)
+ en opt. PCD7.F1xxS
4)
– – – – – – – – 4 4 4 2 – 1 2 – – –
PCD2.F2610 DALI y compris alimentation du bus
6)
– – – – – – – – 4 4 4 2 – 1 2 – – –
PCD2.F27x0 M-Bus maître
5)
– – – – – – – – 4 4 4 2 – 1 2 – – –
PCD2.F2810 Bus MP de Belimo
5)
+ en opt. PCD7.F1xxS – – – – – – – – 4 4 4 2 – 1 2 – – –
Emplacements pour modem (A1/A2)
– – – – – – – – – – 2 – – – – – – –
Utilisation d'un modem externe par les interfaces RS-232
● ● ● ● ● ●
– –
● ● ● ● ● ● ● ● ● ●
2.2