SBC S-Bus available? (FAQ #100179) Yes, the product Saia PCD® COSinus (PCD8.DNET-SUITE) does also contain the SBC S-Bus libraries (S-Bus Master and/or S-Bus Slave) based on the Microsoft .Net framework. How is the Saia PCD® COSinus structured? The Saia PCD® COSinus contains different components (S-Bus Master, S-Bus [...] of PG5 does store the modified TAPI settings in the registry of Windows under the key name: HKEY_LOCAL_MACHINE\SOFTWARE\SAIA-Burgess\PG5\x.y\Channels\S-Bus Modem\ Tapi
SBC S-Bus available? (FAQ #100179) Yes, the product Saia PCD® COSinus (PCD8.DNET-SUITE) does also contain the SBC S-Bus libraries (S-Bus Master and/or S-Bus Slave) based on the Microsoft .Net framework. How is the Saia PCD® COSinus structured? The Saia PCD® COSinus contains different components (S-Bus Master, S-Bus [...] of PG5 does store the modified TAPI settings in the registry of Windows under the key name: HKEY_LOCAL_MACHINE\SOFTWARE\SAIA-Burgess\PG5\x.y\Channels\S-Bus Modem\ Tapi
unless the PCD is connected over a VPN connection only (because even with the password protection of S-Bus will still allow everyone to modify media values as e.g. Register Values [...] of PG5 does store the modified TAPI settings in the registry of Windows under the key name: HKEY_LOCAL_MACHINE\SOFTWARE\SAIA-Burgess\PG5\x.y\Channels\S-Bus Modem\ Tapi [...] ). How to provide the IP address of a PCD as URL? Instead of the IP address, also a URL can be entered: This notation can be used for Ether-S-Bus connections and for http connections
unless the PCD is connected over a VPN connection only (because even with the password protection of S-Bus will still allow everyone to modify media values as e.g. Register Values [...] of PG5 does store the modified TAPI settings in the registry of Windows under the key name: HKEY_LOCAL_MACHINE\SOFTWARE\SAIA-Burgess\PG5\x.y\Channels\S-Bus Modem\ Tapi [...] ). How to provide the IP address of a PCD as URL? Instead of the IP address, also a URL can be entered: This notation can be used for Ether-S-Bus connections and for http connections
The default Timeout on Profi-S-Bus is baudrate related: Baudrate 9'600 Baud: 500 ms 93,75 kBaud: 500 ms 187,5 kBaud: 250 ms 500 kBaud: 250 ms 1,5 MBaud: 100 ms
On Profibus Network it is important to use the right cable and connector as the communication speed goes up to 12 Mbautes! Those cable and connectors are used in Profibus DP, FMS, Profis S-Bus, Profi S-IO and MPI!
This error message can have two reasons; one caused by a TCP connection which has been closed by the server, of if the S-Bus connection is not working correctly.
If the PG5 (or the S-Bus driver SCommDdll) is already running and one doubleclicks a PG5 program file (such as *.src or *.fup), it is possible that the file is not opened but a window named SCommCom with the message "Try to load another SCommCom.dll..." is shown.
The "secure S-Bus Data Mode" has been introduced in order to clearly identify a Serial-S-Bus response telegram as answer to a certain request telegram (by introducing a sequence number). This FAQ explains the difference between the "standard S-Bus Data Mode" and the "secure S-Bus Data Mode".
By default the S-Energy manager (PCD7.D4xxE) does have the S-Bus address 2 as written in the manual.