In case a "non Saia PCD® COSinus" PCD or PCS1 system is connected with "Secure S-Bus Data mode" (e.g. over a serial cable or over modem) from time to time a telegram is not answered correctly.
The S-Bus OPC-Server does run on 32 bit and 64 bit Computers: Windows Vista Windows Server 2008 (also R2) Windows 7 Windows 8 Windows 8.1 Windows 10 Windows 11
Due of an error of PG5 2.0 and PG5 2.1 it’s not possible to configure on the device configurator correctly the Profi-S-Bus of the PCD1.M2xx0. The device configurator uses the port 2 for Profi-S-Bus, instead to use the port 0. The error is fixed on PG5 2.1 version PG5 $2.1.047
3-phase bidirectional energy meter with transformer connection and serial S-bus interface Specifications: - 3-phase energy meter, 3 × 230 / 400 VAC 50 Hz - Converter metering to 1500 A in both directions of current - Display of the active power, voltage and current per phase - Display of the total active power - S-bus interface used to query data - Idle power per phase or total available via the interface - Up to 254 energy meters can be connected to a single S-bus interface. - 7-digit LCD display for energy supply and feeding back - Can be sealed and is provided
Compact room controller with serial S-Bus interface Compact room controller 24 VAC with 2 triac outputs for 2 thermal valves (PWM) or 1 valve 3-point (open/close), 2x 0…10 V outputs, 2 digital inputs, integrated temperature sensor and analogue user interface for setpoint adjustment and presence
Compact room controller with serial S-Bus interface Compact room controller 24 VAC with 2 triac outputs for 2 thermal valves (PWM) or 1 valve 3-point (open/close), 2 digital inputs, integrated temperature sensor and analogue user interface for setpoint adjustment and presence
Due of an error on PG5 2.1.420, a download of the application program to the PCS1 does delete the S-Bus configuration which was loaded previously with the PG5 device configurator The error is fixed in PG5 2.1.430.
There are several reasons to use the FBox "SASI S-Bus Extended" (see FAQ 101400). But there is a limitation that it is not possible to use this FBox for re-assigning a port as Gateway master port on Saia PCD® COSinus systems.
Since the version 2.02.16.06 of the S-Bus OPC-Server there is the possibility to set a new parameter “delay” on the station settings page. This parameter defines the waiting time between two connections, if the preceding connection was not finished correctly.
Order Number Standard Version: ALD1D5FS00A2A00 MID Version: ALD1D5FS00A3A00 Sealing caps: 4 104 7420 0 Main features - Single-phase energy meter, 230 VAC 50 Hz - Direct measurement up to 32 A - Display of active power, voltage and current - S-Bus Interface to query the data - Reactive power and cos PHI available through interface - Up to 254 meter can be connected to the S-Bus Interface - 7-digit display - Lead seal possible with cap as accessory - Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21