E-Line digital input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC - 16 digital inputs 24 VDC (source operation) - 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) - 1 interface RS-485 (S-Bus and Modbus)
E-Line digital input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC - 24 digital inputs 24 VDC (source operation) - 6 relay normally open 230 VAC / 30 VDC, 4 A (resistive load) - 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) - 1 interface RS-485 (S-Bus and Modbus)
E-Line digital input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC - 4 digital inputs 24 VDC (source operation) - 6 relay normally open 230 VAC / 30 VDC, 4 A (resistive load) - 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) - 1 interface RS-485 (S-Bus and Modbus)
E-Line S-Serie digital output module manual override operating level for all outputs status LED for outputs supply 24 VDC - 6 relay normally open 230 VAC / 30 VDC, 16 A (resistive load) - 1 interface RS-485 (S-Bus and Modbus) - 1 USB Service interface
E-Line S-Serie digital output module Manual override operating level for all outputs Status LED for outputs Supply 24 VDC - 10 digital outputs 24 VDC (12…32 VDC/0.5 A) - 1 interface RS-485 (S-Bus and Modbus) - 1 USB service interface
Single-phase energy meters with integral serial S-Bus interface for direct measurement, 230 VAC - 50 Hz Main features: Single-phase energy meter with LCD display - S0 pulse output = 1'000 pulses/kWh - Imax = 32 A, - 1 tariff
Programmable E-Line input/output module for room automation supply 24 VAC/VDC - 8 digital inputs 24 VAC/VDC - 3 relay changeover 230 VAC / 30 VDC, 6 A, max. inrush current 15 A - 1 relay changeover 230 VAC / 30 VDC, 10 A, max. inrush current 65 A - 4 triac outputs 24 VCA/1A or 230 VAC/1 A - 4 analogue inputs 12 bits 0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm - 4 analogue outputs 12 bits, 0…10 V (3 mA max.) - 3 interfaces: RS-485 (S-Bus), USB & NFC (service)
Programmable E-Line input/output module for room automation with auxiliary RS-485 interface supply 24 VAC/VDC - 8 digital inputs 24 VAC/VDC - 3 relay changeover 230 VAC / 30 VDC, 6 A, max. inrush current 15 A - 1 relay changeover 230 VAC / 30 VDC, 10 A, max. inrush current 65 A - 4 triac outputs 24 VCA/1A or 230 VAC/1 A - 4 analogue inputs 12 bits 0…10 V, ±10 V, 0(4)…20 mA, Pt/Ni 1000, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm - 4 analogue outputs 12 bits, 0…10 V (3 mA max.) - 4 interfaces: RS-485 (S-Bus), auxiliary RS-485, USB & NFC (service)
Combinable room control system with serial S-Bus interface for fan-coil and air quality control applications Double room controller 230 VAC for radiator/cooling ceiling combinations and VAV applications with: - 4 triac outputs, - 2 outputs 0…10 V, - 2 relays for electrical heating and autonomous interfaces for digital room control units
Digital room control unit with S-Bus or Modbus interface Digital room operating device for multi-room applications and low installation cost trough 2 Pluggable RJ9 connectors for daisy chain up to 6 wall units, Integrated Room temperature sensor 0…40°C and Set point offset control ± 3°C in steps of 0.5°C, 7 LED for signalization of set point offset, RS-485 interface for S-Bus or Modbus communication PEHA Dialog Aluminium design