program PCD1.Mxxx, PCD2.M150/170, PCD4.M170 or PCD6.M300 you need the intermediate firmware version $301 since S-Bus is not supported by earlier versions. Contact your local SAIA sales company to get this
E-Line S-Serie combined input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC - 8 universal digital/analogue inputs - digital inputs 24 VDC - analoque inputs 12 bits 0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm - 4 analogue outputs 10 bits, 0…10 V - 1 interface RS-485 (S-Bus and Modbus) - 1 USB Service interface
E-Line S-Serie combined input/output module manual override operating level for all outputs status LED for inputs and outputs supply 24 VDC - 6 universal digital/analogue inputs - digital inputs 24 VDC - analoque inputs 12 bits 0…10 V, Pt/Ni 1000, Ni 1000 L&S, NTC, 0…2500 Ohm, 0…7500 Ohm, 0…300 kOhm - 2 analogue outputs 10 bits, 0…10 V - 2 triac outputs 24 VAC/1 A or 230 VAC/1 A - 1 interface RS-485 (S-Bus and Modbus) - 1 USB Service interface
01 0271 0022 fexible cable Note: If the bautrates isn't greater than 187,5 bautes (for ex. Profi S-Bus with PCD3.M3xx / PCD7.D7xx) you can use other more advantegeous cable, especially [...] and connector as the communication speed goes up to 12 Mbautes! Those cable and connectors are used in Profibus DP, FMS, Profis S-Bus, Profi S-IO and MPI! Wiring and Network [...] for the port 3 of the PCD3.M5540 as Serial-S-Bus RS485 connection (Serial-S-Bus) between PCD3.M5540 port 3 (S-Net D-Sub used as RS485 Serial-S-Bus) and PCD2.M5540 port 2 (connector block X
01 0271 0022 fexible cable Note: If the bautrates isn't greater than 187,5 bautes (for ex. Profi S-Bus with PCD3.M3xx / PCD7.D7xx) you can use other more advantegeous cable, especially [...] and connector as the communication speed goes up to 12 Mbautes! Those cable and connectors are used in Profibus DP, FMS, Profis S-Bus, Profi S-IO and MPI! Wiring and Network [...] for the port 3 of the PCD3.M5540 as Serial-S-Bus RS485 connection (Serial-S-Bus) between PCD3.M5540 port 3 (S-Net D-Sub used as RS485 Serial-S-Bus) and PCD2.M5540 port 2 (connector block X
product macros, DWG and DXF files can be found here . Analyzer For analyzing Ether-S-Bus communication or Ethernet communication in general, we recommend using the free software Wireshark ( [...] is able to dissect Ether-S-Bus from version 1.1 on. For more information please refer to the according FAQ #100569 .
product macros, DWG and DXF files can be found here . Analyzer For analyzing Ether-S-Bus communication or Ethernet communication in general, we recommend using the free software Wireshark ( [...] is able to dissect Ether-S-Bus from version 1.1 on. For more information please refer to the according FAQ #100569 .
Product Category Remote I/O PCD7.Lxxx S-Bus RIO L5xx: RIO Power supply [...] -100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room [...] with use of the PCD7.L60x S-Bus room controllers (not LON
-100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room [...] with use of the PCD7.L60x S-Bus room controllers (not LON [...] sensor to the input E2 (and select in the config FBox its functionality as dew point): If the dew point has to be set over the S-Bus or in the "Room" FBox, then it has to be used in minimum the
-100.0 Communication on serial S-Bus fails while the AutoConfig Output of the Setup FBox stays '1'! (FAQ #101812) L60x Config, L60x Room [...] with use of the PCD7.L60x S-Bus room controllers (not LON [...] sensor to the input E2 (and select in the config FBox its functionality as dew point): If the dew point has to be set over the S-Bus or in the "Room" FBox, then it has to be used in minimum the