firmware. Solution At the moment the dynamic space has to be defined >=1000 and Timeout -> TS-Delay -> TN-Delay -> Break length ) If you want to disable the "Secure S-Bus Data mode" If you [...] ) Why does the FBox "SASI S-Bus Extended" not work (for assigning a gateway master port)? (FAQ #101399) There are several reasons to use the FBox "SASI S-Bus Extended" (see FAQ 101400). But there is a limitation that it is not possible to use this FBox for re-assigning a port as Gateway master port on Saia PCD® COSinus systems
PLC with 128 KBytes of user memory Backup with internal Flash memory, USB port for PG5 max. 64 digital I/Os (not expandable), 2 interrupts, Web-Server, RS-485 for Profi-S-Net or S-Bus, Ethernet TCP/IP
E-Line S-Serie Digital input module status LED for inputs supply 24 VDC - 12 Digital inputs 24 VDC (source operation) - 1 interface RS-485 (S-Bus and Modbus) - 1 USB service interface
PLC with 512 KBytes of user memory, Backup with internal Flash memory, USB port for PG5 max. 64 digital I/Os (not expandable), 2 interrupts, Web-Server, RS-485 for Profi-S-Net or S-Bus, Ethernet TCP/IP
Yes, it is possible to use the S-Net MPI port on the PCD3.M5xxx as free RS 485 port (S-Bus or Mode C per example).
transfer from the S-Bus driver to the Ether-S-Bus driver. See the description below Procedure for the conversion of a PCD8.D81W project Open the project and move the SBC S-Bus driver from ASP to MSP. Convert the panel from Vxxx rev 4 to VTxxx ETH. Drag and drop the driver "SBC Ethernet S-Bus" to the Ethernet port. Open the [...] D763 loses communication on Profi S-Bus! (FAQ #100477) On a Profi S-Bus network when PCD7.D76_ terminals are
transfer from the S-Bus driver to the Ether-S-Bus driver. See the description below Procedure for the conversion of a PCD8.D81W project Open the project and move the SBC S-Bus driver from ASP to MSP. Convert the panel from Vxxx rev 4 to VTxxx ETH. Drag and drop the driver "SBC Ethernet S-Bus" to the Ethernet port. Open the [...] D763 loses communication on Profi S-Bus! (FAQ #100477) On a Profi S-Bus network when PCD7.D76_ terminals are
230 VAC / 30 VDC, 4 A (resistive load) 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) 1 interface RS-485 for S-Bus and Modbus, Modbus support since FW 1 [...] open 230 VAC / 30 VDC, 4 A (resistive load) 4 relay changeover 230 VAC / 30 VDC, 4 A (resistive load) 1 interface RS-485 for S-Bus and Modbus, Modbus support since FW 1 [...] 230 VAC / 30 VDC, 4 A (resistive load) 1 interface RS-485 for S-Bus and Modbus, Modbus support since FW 1.08.04 PCD
...300 kOhm 4 analog outputs 10 bits, 0...10 V (10 mA max.) 1 interface RS-485 for S-Bus and Modbus, Modbus support since FW 1.08.04 PCD [...] ...10 V, Pt/Ni 1000, NI1000 L&S, NTC, 0...2500 Ohm, 0...7500 Ohm, 0...300 kOhm 8 analog outputs 10 bits, 0...10 V (10 mA max.) 1 interface RS-485 for S-Bus and Modbus, Modbus support since FW 1 [...] interface RS-485 for S-Bus and Modbus, Modbus support since FW 1.08.04 Documentation Web-templates for Web-Editor8 E-Line configuration App The E-Line App does allow to
Combinable room control system with serial S-Bus interface for fan-coil and air quality control applications Room controller 230 VAC with_ - 2 triac outputs, - 2 outputs 0…10 V, - incl. 24 VAC (7 W) supply, - 1 relay for electrical heating, - 3-stage or variable fan speed control, - with additional air quality control - and light & sunblind functionality