Yes, it’s possible to connect up to 16 MP-Bus devices per MP-Bus line and the PCD supports the MP-Bus light protocol. Belimo has enhanced the functionality of the MP-Bus in that way that, in some conditions, it’s possible to connect up to 16 devices on the same MP-Bus.
The serial number of the S-Bus, M-Bus or Modbus one-phase and three-phase energy meter is printed on the front of the energy meter and it's also possible to read out the serial number over the communication interface. Until June 2013 the two serial numbers were different one from the other, but each one was unique.
If the SBC S-Bus OPC server was launched by a request of an OPC client located on another machine, the SCommDll (or SCommDrv) is not available for the user working on the PC where the OPC server is running.
the electrical systems (Saia PCD1.M0160E0) is a Function PCD that can be used immediately in the default setting without any programming. Energy meters connected via S-Bus and H104SE gateway modules for [...] PCD1 / _Firmware Classic Why the RS-485 S-Bus [...] possible that the some of the S-Bus telegrams transferred from the PCD S-Bus master to the S-Bus slaves over RS485 are malformed, and the S-Bus slave does reject the request from the master. This could
. PCD1 / E-Line Why the RS-485 S-Bus communication [...] the some of the S-Bus telegrams transferred from the PCD S-Bus master to the S-Bus slaves over RS485 are malformed, and the S-Bus slave does reject the request from the master. This could lead to the situation that for example the PCD S-Bus master don’t receive actual values from E-Line RIO’s or that the program download of a PCD program from the PC to a Slave PCD which is located behind a
The E-Line App does allow to configure the communication protocol on the RS485 of the E-Line RIO’s (S-Bus or Modbus) the baudrate and the parity and stop bit as the station number of the E-Line RIO device. The E-Line App does run on PC’s with Windows 7, Windows 10 and Windows 11 (32/64 - Bit) operation systems. USB connection to the PCD1 E-Line RIO’s is required.
E-Mon BLACK PQA - Saia PCD® Power Quality Analyser PQA - Saia PCD® Power Quality Analyser Energy meters with integral serial S-Bus interface [...] power for every phase and for the three phases. SBC S-Bus M-Bus Modbus S0-interface Saia PCD S0 pulse counters Energy controller for electric cabinet Energy controller with S-Monitoring function Accessories for Energy Meters
communication errors when connecting a PCD/PCS in "Secure S-Bus Data Mode"? (FAQ #101180) In case a "non Saia PCD® COSinus" PCD or PCS1 system is connected with "Secure S-Bus Data mode" (e.g. over a serial cable or over modem) from time to time a telegram is not answered correctly. Symptom A PCD or a PCS connected with another system (e.g. PC or another PCD system) using the "Secure S-Bus Data mode" does not answer a telegram from time to time. This can e.g. be seen by a red LED on transmit or receive FBoxes
communication errors when connecting a PCD/PCS in "Secure S-Bus Data Mode"? (FAQ #101180) In case a "non Saia PCD® COSinus" PCD or PCS1 system is connected with "Secure S-Bus Data mode" (e.g. over a serial cable or over modem) from time to time a telegram is not answered correctly. Symptom A PCD or a PCS connected with another system (e.g. PC or another PCD system) using the "Secure S-Bus Data mode" does not answer a telegram from time to time. This can e.g. be seen by a red LED on transmit or receive FBoxes
HONEYWELL S0 pulse counter with Modbus interface Main features - Up to 99 S0-Modbus Modules on the same bus - 4 S0 pulse inputs (S01+... S04+) per S0-Modbus Module - Up to 396 S0 devices on the same Modbus - The inputs comply with the S0 standard 62053-31 - Integrated RS-485 termination resistor - LED for bus activity indication