) Problem with the FBox HD Log to File if the dynamic space of registers is defined as =10 000 (FAQ #101429) In case the dynamic space of registers is defined below 1000 or above 9999 the FBox HD Log to file cannot create the Logfiles correctly Problem If the dynamic space of registers is defined =10 000 the FBox HD Log to File is not able to create the Logfile correctly. The FBox is using interpreted text with $R commands. Due to a problem in the FBox this won't work for registers below 1000 since they only
shown. How to solve the problem? On the wvar file do click with the right mouse key to the concerned variable and select rename. On the next window put the cursor at the end of the [...] correctly - It’s possible that you have Index Register Overflow message in the PCD history Only the PCS1 is concerned from this problem. See the FAQ 101832 for more information and the solution to fix the problem
shown. How to solve the problem? On the wvar file do click with the right mouse key to the concerned variable and select rename. On the next window put the cursor at the end of the [...] Register Overflow message in the PCD history Only the PCS1 is concerned from this problem. See the FAQ 101832 for more information and the solution to fix the problem [...] variable is copied from the Web-Editor8 help file with copy paste in to the Web-editor8 painter, then it’s possible that not only the name of the variable is copied but also an invisible 'CR''LF' character
not vice versa since libraries for PG5 can contain new functionalities not supported by PG4. PG4 only: The format of the user and system text files used for heavac dialogue has changed between PG4 version 1.4 and version 2.0.xxx, which can cause problems when old applications are edited with version 2.0.xxx. Rename the both hea.. text files in the project folder and copy the standard text files from the fbox folder into the current project folder. If your application is running with the standard texts start to copy/paste the texts of the original files into the new files.
bigger (100-200MBytes). Problem The size of the project increase after storing to a really hughe size. Reason If unicode fonts are used which are not present in the PC [...] 't le possibility to use this version and you have the version 5.12 you can also add the new Fw in attachment. So, please execute the following steps: Download the files attached to this FAQ and unzip the archives. Copy the firmware files "VT155W.BIN" into the following folder: "C:\Program Files\SAIA\PCD8.D81W_512\\firmware\" Open the VTWIN project, compile it again and
problem the attached file vtwindev.dbr has to be copied in the main directory PCD8.D81W software, this will replace the existing file [...] 't le possibility to use this version and you have the version 5.12 you can also add the new Fw in attachment. So, please execute the following steps: Download the files attached to this FAQ and unzip the archives. Copy the firmware files "VT155W.BIN" into the following folder: "C:\Program Files\SAIA\PCD8.D81W_512\\firmware\" Open the VTWIN project, compile it again and
FileZilla (e.g. that the IMasterSaia.jar was not completely downloaded). Symptoms There were problems while downloading several files in parallel to the PLC Filesystem. And sometimes [...] . Conclusion As these problems are only concerning few installations we do not intend to "forbid" the usage of the the FTP Client FileZilla together with the PCD FTP Server. However, in case you are faced [...] limit the transfer speed. Switching on this speed limitation does allow loading without problems files to the PCD. To enable the speed limit, click on the tachometer symbol (on the bottom right corner
start the panel has a blue screen with some error messages. This problem occur only if an Ethernet cable is connected on the LAN Port A. The error comes from the driver of the LAN port. Solution The problem is corrected on driver 2.7.1.0 or higher. Copy the attached .exe file and execute the installation file for updating the driver. Of course HORM and EWF modes have to be disable before! How
5. Problem The internal symbols of the PCD7.L60x FBox are missing. Normally they should be created automatically when the FBox is placed in a Fupla File Reason and Solution If this does not happen [...] you have to import the File BAC_L79x_RIO/ROOM into the PG5 project. Also the FBox Library > 2.6.134 is needed. The differences between the PCD7.L79x and PCD7.L79xN are described in the document [...] correctly displayed: 20.6°C! This is only a visualisation probleme during the modifiation of the set point! Reason: Because over RJ9 protocol (used to communicate between the PCD
5. Problem The internal symbols of the PCD7.L60x FBox are missing. Normally they should be created automatically when the FBox is placed in a Fupla File Reason and Solution If this does not happen [...] correctly displayed: 20.6°C! This is only a visualisation probleme during the modifiation of the set point! Reason: Because over RJ9 protocol (used to communicate between the PCD [...] automaticaly. Possible problem: If the auto configuration option is activated during the powerup and the FBox Configuration isn't enable and the register ConfigTime Stamp (R=126) doesn