protocol for PCD2/3.F2xx(x) e.g. used by the M-Bus library 2.6.100 and later SF library 23: Energy Manager library SF library 25: LON FT library SF library 27: ELine library for ELine modules [...] for PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD2.M5xx0, PCD3.Mxxx0, PCD3.Mxx60, PCD3.M6860, PCD3.M6880, PCD3.T665, PCD3.T666, PCD3.T668, PCD7.D4xxxT5F, PCD7.D4xxV, PCD7.D4xxD, PCD7.D4xxWTPF, PCD7.D443WTxR and [...] 2.M4x60 PCD2.M5xx0 PCD3
protocol for PCD2/3.F2xx(x) e.g. used by the M-Bus library 2.6.100 and later SF library 23: Energy Manager library SF library 25: LON FT library SF library 27: ELine library for ELine modules [...] for PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD2.M5xx0, PCD3.Mxxx0, PCD3.Mxx60, PCD3.M6860, PCD3.M6880, PCD3.T665, PCD3.T666, PCD3.T668, PCD7.D4xxxT5F, PCD7.D4xxV, PCD7.D4xxD, PCD7.D4xxWTPF, PCD7.D443WTxR and [...] 2.M4x60 PCD2.M5xx0 PCD3
3-phase energy meter ALE3 with M-Bus (bidirectional) Order number MID version: ALE3B5FM00C3A00 Sealing cap: 4 104 7485 0 Specifications - 3-phase energy meter, 3 × 230 / 400 VAC 50 Hz - Direct metering to 65 A in both directions of current - Display of the active power, voltage and current per phase - Display of the total active power - M-Bus interface used to query data - Idle power per phase or total available via the interface - Up to 254 energy meters can be connected to a single M-Bus interface. - 7-digit LCD display for energy supply and feeding back - Can be sealed and is provided
Three-phase two-way energy meter with LCD display M-Bus interface, Imax = 65 A display of active power, voltage and current according to MID directive
installation (the amount of PCs on which PG5 is running in a company is not relevant). Known issues / patches After a update of java to the version 1.7.0_51-b13 it's no more possible to display [...] _15_02.jar, IMasterxx7_5_15_02.jar Bacnet: • Crash if tried to open a BACNet file which is deleted in Device Folder • For PCD3.Mxx60 and PCD1.M2xxx a donwnload of the program does not erase the whole [...] features of the SP1 (PG5 2.0.150) are: S-Web and FTP Server and IP Enhancements can be configured in the Device Configurator, see FAQ 101464 . Increased amount of available flags on a PCD3 or a
installation (the amount of PCs on which PG5 is running in a company is not relevant). Known issues / patches After a update of java to the version 1.7.0_51-b13 it's no more possible to display [...] _15_02.jar, IMasterxx7_5_15_02.jar Bacnet: • Crash if tried to open a BACNet file which is deleted in Device Folder • For PCD3.Mxx60 and PCD1.M2xxx a donwnload of the program does not erase the whole [...] features of the SP1 (PG5 2.0.150) are: S-Web and FTP Server and IP Enhancements can be configured in the Device Configurator, see FAQ 101464 . Increased amount of available flags on a PCD3 or a
installation (the amount of PCs on which PG5 is running in a company is not relevant). Known issues / patches After a update of java to the version 1.7.0_51-b13 it's no more possible to display [...] _15_02.jar, IMasterxx7_5_15_02.jar Bacnet: • Crash if tried to open a BACNet file which is deleted in Device Folder • For PCD3.Mxx60 and PCD1.M2xxx a donwnload of the program does not erase the whole [...] features of the SP1 (PG5 2.0.150) are: S-Web and FTP Server and IP Enhancements can be configured in the Device Configurator, see FAQ 101464 . Increased amount of available flags on a PCD3 or a
Restrictions Protocol to read values of counters and other measurement equipment. The M-Bus master modules PCD2.F27x0 and PCD3.F27x can be use to connect M-Bus slaves (modules are available for PCD1.M2xx0, PCD2.M5xx0 and PCD3). For PCD2.M1x0 a system partner provides a solutions with a gateway to M-Bus, refer to www.engiby.ch for more details. In this case besides the FBox library (used in every case) an M-Bus converter is required, please refer to www.relay.de for instance. M-Bus master modules PCD2.F27x0 and PCD3.F27x, together
Mounting Instructions & Users Guide: Release E 2022-02-18 - The approval for printing has been given - Gut zum Druck! - M. Habenicht - UKCA marking added - Address of importing company added - New responsible signatory - New company address of SBC added SBC: ALE3B5FM00C3A00
M-Bus on Saia PCD® PCD2.F27x0 and PCD3.F27x Introduction A PCD1.M2, PCD2.M5 or PCD3 [...] /O slot 0..3. The difference between the types is the amount of M-Bus slaves which can be connected per module (on the two ports) Modules for the PCD1.M2 and PCD2.M5 PCD2.F2700 PCD2.F [...] Product Category Programmable controller PCD3: CPUs, cassette design Fxxx: Comm modules F2xx: for I/O slot 0..3 F27x: M-Bus