The PCD3.M6880 Standby Controllers are for creating redundant automation solutions, to ensure the uninterrupted operation of systems and processes.
For BCU1 protocol not all communication interfaces of a PCD3 or a PCD2.M5540 can be used. On the other hand there is no problem using the newer FT1.2 protocol which is supported by all RS232 interfaces of the PCD3 and the PCD2.M5540.
to use a PLC with SD Flash for example PCD3.M3330 (R600 Module + 3x DALI), or PCD3.M5560 for up to 4 DALI modules [...] 101653 . Minimal firmware version for the Manager is 1.16.42 (PCD1.M2) and 1.16.45 (PCD2.M5 and PCD3), see FAQ 101640 . Minimal version of PG5 for configuring a PCD3.T665¦T666 is PG5 2.0 SP2 (PG5 [...] ’. This change has been made in order to be compatible with the Windows 10 start menu that’s accept only one level of folder. Device configurator: PCD3.M3160: Power CPU with 512kByte program
to use a PLC with SD Flash for example PCD3.M3330 (R600 Module + 3x DALI), or PCD3.M5560 for up to 4 DALI modules [...] 101653 . Minimal firmware version for the Manager is 1.16.42 (PCD1.M2) and 1.16.45 (PCD2.M5 and PCD3), see FAQ 101640 . Minimal version of PG5 for configuring a PCD3.T665¦T666 is PG5 2.0 SP2 (PG5 [...] ’. This change has been made in order to be compatible with the Windows 10 start menu that’s accept only one level of folder. Device configurator: PCD3.M3160: Power CPU with 512kByte program
default with a spring clamp terminal block. Screw terminal blocks have to be ordered separately . PCD3 LIO and PCD2.M17x: to use addresses in the range 256 to 511, CPU's with production date 0331 [...] description of the exchangeable amount of data in the Profibus DP manual, a SBC-NT PLC (PCD3, PCD1.M2, PCD2.M5xxx, PCD2.M480) can communicate with a PCD3.T760 a maximum amount of 2'048 bytes [...] (degrees for temperature and e.g. mV for the voltage inputs). Procedure In the S-Net configurator, select a PCD3.W200 for the module where the PCD2.W220Z12 is plugged Select the format
default with a spring clamp terminal block. Screw terminal blocks have to be ordered separately . PCD3 LIO and PCD2.M17x: to use addresses in the range 256 to 511, CPU's with production date 0331 [...] description of the exchangeable amount of data in the Profibus DP manual, a SBC-NT PLC (PCD3, PCD1.M2, PCD2.M5xxx, PCD2.M480) can communicate with a PCD3.T760 a maximum amount of 2'048 bytes [...] (degrees for temperature and e.g. mV for the voltage inputs). Procedure In the S-Net configurator, select a PCD3.W200 for the module where the PCD2.W220Z12 is plugged Select the format
There is a difference in the "SBC Format" between "old" xx7 CPU's (PCD2.M127, 157, 177) and Saia PCD® COSinus based CPUs (PCD3, PCD2.M5xxx7 and PCD2.M487). The way to read analogue values from PCD2/3.W2xx and PCD2/3.W100, W3x0, W500 in the "SBC-Format" is not the same.
In PG5 1.4.300 the new DP Master CPU without ethernet is not available, just the PCD3.M6540 can be selected
The XOB 8 who is called when the firmware detects an invalid instruction (Invalid OPC) in the user program is no longer called on the systems Saia PCD® COSinus (PCD3, PCD2.M5, PCD2.M480).
Is it possible to use the Siemens WinCC visualisation with SBC Classic PCD's? (FAQ #100508) Yes, the company "M [...] . S-Bus communication problems with PCD3 (FAQ #100336) Since the communiction on the PCD3 is not handled the same way [...] FBox libraries "Modbus 2" and "M-Bus" version 2.6.xxx (FAQ #101480) As described in FAQ 101479 the version 2.6.xxx of