CPU base units for 4 plug-in I/O modules - Saia PCD3.M5 series PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 1 MByte user program, backup option with PCD7.R5xx/R610 Flash card, clock (RTC), data protection 1-3 years, USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-232, RS-422/485, RS-485 for Profi-S-Net/S-Bus
There are firmware depending differences in the handling of the Serial-S-Bus communication diagnosic flags TDIA and RDIA. Those flags are refreshed continuously by older FW versions but not by the Saia PCD® COSinus Classic PCD firmware (used for PCD2.M480 and PCD3 controllers).
For "reading" a value from a PCD text (e.g. copying "1234" from a PCD text with content "The next number is: 1234" into a Register) a new System Function has been added for PCD3 and PCD2.M5xx0.
BACnet FW and coresponding PCD FW for PCD1.M2220-C15, PCD1.M2160, PCD2.M4x60, PCD3.Mxx60 and PCD3.M6880 The FW >= 1.28.xx does support the BACnet standard revision 14. This firmware should [...] this release The Memory Module PCD7.R562 or PCD3.R562 is required to run this FW (PCD7.R560, PCD7.R561, PCD3.R560, PCD3.R561 are not supported anymore) Existing BACnet projects (based on standard [...] 2.1.311 or newer) to prevent the loading of the FW 1.24.xx or 1.26.xx to a not compatible PCD.
BACnet FW and coresponding PCD FW for PCD1.M2220-C15, PCD1.M2160, PCD2.M4x60, PCD3.Mxx60 and PCD3.M6880 The FW >= 1.28.xx does support the BACnet standard revision 14. This firmware should [...] this release The Memory Module PCD7.R562 or PCD3.R562 is required to run this FW (PCD7.R560, PCD7.R561, PCD3.R560, PCD3.R561 are not supported anymore) Existing BACnet projects (based on standard [...] 2.1.311 or newer) to prevent the loading of the FW 1.24.xx or 1.26.xx to a not compatible PCD.
Analogue input modules for Saia PCD3 controllers Universal analogue input module, 8 channels, 13 bits (12 bits+sign), selectable by software, 0…10 V, ±10 V, 0…20 mA, ±20 mA, Pt/Ni 1000, 0…2500 Ohm, 0…300 kOhm (for NTC sensors) (2 connectors type K included)
Input/output modules for Saia PCD3 controllers Analogue combined input/output module with galvanic isolation, 6 channels : 4 inputs, 14 bits, 0…10 V, 0(4)…20 mA, Pt 1000, Pt 500 or Ni 1000 (selectable by DIP switch) and 2 outputs, 12 bits, 0…10 V or 0(4)…20 mA (selectable by software FBox, FB)
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 128 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, 128 MByte user Flash memory with file system, clock (RTC), USB port for PG5, up to 64 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus
CPU base units for 4 plug-in I/O modules - Saia PCD3.M3 series PCD3 processor unit with Ethernet TCP/IP, web and FTP server, file system, CPU with 512 KByte user program, backup with on-board Flash memory, clock (RTC), USB port for PG5, up to 1024 I/O, 2 interrupt inputs, RS-485 for Profi-S-Net or S-Bus