-Bus Data mode"). Saia PCD® COSinus based systems (PCD2.M480, PCD2.M5xx0 and PCD3) are not concerned. Reason The reason for this behavior is that the PCD/PCS does not correcly answer telegrams where [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the [...] to the firmware supporting the according feature (see table below). System minimal FW PCS1.Cxxx 0E3 PCD1.M1x5 0E3 PCD2.M150 0E3
-Bus Data mode"). Saia PCD® COSinus based systems (PCD2.M480, PCD2.M5xx0 and PCD3) are not concerned. Reason The reason for this behavior is that the PCD/PCS does not correcly answer telegrams where [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the [...] to the firmware supporting the according feature (see table below). System minimal FW PCS1.Cxxx 0E3 PCD1.M1x5 0E3 PCD2.M150 0E3
measures. Information about protective measures can be found on the support hp If you need a PCD with cyber security levels SL3+ and based on ANSI ISA 62443 then checkout our PCD3.M [...] COSinus FW 1.28.51 was introduced into production for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60 and PCD3.M6880. In February 2019: the COSinus FW 1.28.37 was released as maintenance version for the systems: - PCD1.M0xx0/M2xx0, PCD2.M4x60, PCD3.Mxx60, PCD3.M6880 and PCD3.T665/T666/T668 . In June 2017: the COSinus FW 1.28.16 was introduced into production for the systems
Product Category Programmable controller PCD3: CPUs, cassette design Mxxxx: CPUs M2xxx PCD3 Compact [...] compatible package. Good to know To use PCD3.M3160, PCD3.M3360 or PCD3.M5360, PG5 2.2.130 or newer is required. When upgrading from firmware 1.10.xx or 1.14.xx to 1 [...] PCD3 On a PCD3.M6860 it’s possible to use BACnet
Product Index Archive PCD3 Mxxx: CPUs M2xxx PCD3 Compact General [...] compatible package. Good to know To use PCD3.M3160, PCD3.M3360 or PCD3.M5360, PG5 2.2.130 or newer is required. When upgrading from firmware 1.10.xx or 1.14.xx to 1 [...] Why on a PCD3.M5/6xxx or a PCD2.M45xx the battery LED is switched on and the battery error message is activated in the application program after a new battery was inserted? (FAQ #102039)
Product Category Programmable controller PCD3: CPUs, cassette design Mxxxx: CPUs M2xxx PCD3 WAC [...] PCD3.M2330Tx PCD3 Wide Area Controller (WAC) [...] . PCD3 On a PCD3.M6860 it’s possible to use BACnet
Product Index Archive PCD3 Mxxx: CPUs M2xxx PCD3 WAC General [...] . PCD3.M2330Tx PCD3 Wide Area Controller (WAC) [...] Why on a PCD3.M5/6xxx or a PCD2.M45xx the battery LED is switched on and the battery error message is activated in the application program after a new battery was inserted? (FAQ #102039)
-Bus Data mode"). Saia PCD® COSinus based systems (PCD2.M480, PCD2.M5xx0 and PCD3) are not concerned. Reason The reason for this behavior is that the PCD/PCS does not correcly answer telegrams where [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the [...] to the firmware supporting the according feature (see table below). System minimal FW PCS1.Cxxx 0E3 PCD1.M1x5 0E3 PCD2.M150 0E3
-Bus Data mode"). Saia PCD® COSinus based systems (PCD2.M480, PCD2.M5xx0 and PCD3) are not concerned. Reason The reason for this behavior is that the PCD/PCS does not correcly answer telegrams where [...] appears if the used firmware on the CPU does not support the "active and non ACK" filter for the S-Web alarming functionality (e.g. a PCD2.M150 with firmware 0D3). Symptom Instead of the [...] to the firmware supporting the according feature (see table below). System minimal FW PCS1.Cxxx 0E3 PCD1.M1x5 0E3 PCD2.M150 0E3
5440 FW 1.16.52 FW >= 1.16.69 HW F ok ok HW G1 No 24V on MPI ok PCD3.M5560 FW 1 [...] On a PCD2.M4560 or PCD3.M5560, why the measured PT100 temperature values are not correct if the PT100 sensors are connected to PCD2.W220Z18 or PCD3.W220Z18 modules? (FAQ #102052) [...] Why the MPI adapter doesn’t work on the MPI port of the PCD3.M5547, PCD3.M5567, PCD3.M5540, PCD3.M5440 or PCD3.5560? (FAQ #101814)